Stent Coverage and Neointimal Proliferation in Bare Metal Stents Postdilated With a Paclitaxel-Eluting Balloon Versus Everolimus-Eluting Stents Prospective Randomized Study Using Optical Coherence Tomography at 6-Month Follow-Up

被引:29
|
作者
Poerner, Tudor C. [1 ]
Otto, Sylvia
Gassdorf, Johannes [1 ]
Nitsche, Kristina [1 ]
Janiak, Florian [1 ]
Scheller, Bruno [2 ]
Goebel, Bjoern [1 ]
Jung, Christian [1 ]
Figulla, Hans R. [1 ]
机构
[1] Univ Hosp Jena, Dept Med 1, Div Cardiol, Jena, Germany
[2] Univ Saarland, D-66123 Saarbrucken, Germany
关键词
coronary stenosis; drug-eluting stents; percutaneous coronary intervention; tomography; optical coherence; transluminal coronary balloon dilation; PERCUTANEOUS CORONARY INTERVENTION; DUAL-ANTIPLATELET THERAPY; COATED BALLOON; CONVENTIONAL ANGIOPLASTY; ARTERY-DISEASE; RESTENOSIS; LESIONS; TRIAL; IMPLANTATION; REVASCULARIZATION;
D O I
10.1161/CIRCINTERVENTIONS.113.001146
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-In this randomized trial, strut coverage and neointimal proliferation of a therapy of bare metal stents (BMSs) postdilated with the paclitaxel drug-eluting balloon (DEB) was compared with everolimus drug-eluting stents (DESs) at 6-month follow-up using optical coherence tomography. We hypothesized sufficient stent coverage at follow-up. Methods and Results-A total of 105 lesions in 90 patients were treated with either XIENCE V DES (n=51) or BMS postdilated with the SeQuent Please DEB (n=54). At follow-up, comparable results on the primary optical coherence tomography end point (percentage uncovered struts 5.64+/-9.65% in BMS+DEB versus 4.93+/-9.29% in DES; P=0.366) were found. Thus, BMS+DEB achieved the prespecified noninferiority margin of 5% uncovered struts versus DES (difference between treatment means, 0.71%; one-sided upper 95% confidence interval, 4.14%; noninferiority P=0.04). Optical coherence tomography analysis showed significantly more global neointimal proliferation in the BMS+DEB group (15.7+/-7.8 versus 11.0+/-5.2 mm(3) proliferation volume/cm stent length; P=0.002). No significant focal in-stent stenosis analyzed with angiography (percentage diameter stenosis at follow-up, 22.8+/-11.9 versus 16.9+/-10.4; P=0.014) and optical coherence tomography (peak local area stenosis, 39.5+/-13.8% versus 36.8+/-15.6%; P=0.409) was found. Conclusions-Good stent strut coverage of >94% was found in both therapy groups. Despite greater suppression of global neointimal growth in DES, both DES and BMS+DEB effectively prevented clinically relevant focal restenosis at 6-month follow-up.
引用
收藏
页码:760 / U53
页数:10
相关论文
共 50 条
  • [31] FAVORABLE NEOINTIMAL COVERAGE IN EVEROLIMUS-ELUTING STENT AT 9 MONTH AFTER STENT IMPLANTATION: COMPARISON WITH SIROLIMUS-ELUTING STENT USING OPTICAL COHERENCE TOMOGRAPHY
    Choi, Hyun-Hee
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Hong, Myeong-Ki
    Jang, Yangsoo
    Sim, Won-Heum
    Cho, Seung-Yun
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [32] OPTICAL COHERENCE TOMOGRAPHY ACCURATELY DETERMINES NEOINTIMAL COVERAGE AND STENT AREA OF BARE METAL AND DRUG-ELUTING CORONARY STENTS
    Mills, James S.
    Stack-N'diaye, Colleen
    Povsic, Thomas
    Yow, Eric
    Urtz, Mark
    Greenfield, Joseph
    Phillips, Harry
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1743 - E1743
  • [33] Neointimal Coverage Of Paclitaxel And Sirolimus Eluting Stents Implanted In Different Types Of Lesions - Long Term Follow-up With Optical Coherence Tomography
    Rdzanek, Adam
    Pietrasik, Arkadiusz
    Kochman, Janusz
    Scibisz, Anna
    Pawlak, Maciej
    Opolski, Grzegorz
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 204I - 204I
  • [34] Comparison of neointimal coverage between ultrathin biodegradable polymer-coated sirolimus-eluting stents and durable polymer-coated everolimus-eluting stents: 6 months optical coherence tomography follow-up from the TAXCO study
    Abhyankar, Atul
    Abizaid, Alexandre
    Chamie, Daniel
    Rathod, Mihir
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 97 (03) : 423 - 430
  • [35] SERIAL CHANGES OF NEOINTIMAL COVERAGE CONDITIONS OF SIROLIMUS-ELUTING STENTS IMPLANTATION: FOLLOW-UP OPTICAL COHERENCE TOMOGRAPHY STUDY
    Nakamura, Daisuke
    Nishino, Masami
    Lee, Yasuharu
    Yoshimura, Takahiro
    Taniike, Masayuki
    Makino, Nobuhiko
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Tanouchi, Jun
    Yamada, Yoshio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1735 - E1735
  • [36] Comparison of paclitaxel versus Sirolimus-eluting stents for coronary lesions in diabetes: A prospective multicenter randomized, 6-month angiographic follow-up study
    Kim, HS
    Lee, SW
    Lee, JH
    Park, JH
    Lee, NH
    Seong, IW
    Ko, JK
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 53H - 53H
  • [37] Long-Term Follow-up of Neointimal Coverage of Sirolimus-Eluting Stents - Evaluation With Optical Coherence Tomography -
    Ishigami, Ken-ichi
    Uemura, Shiro
    Morikawa, Yoshinobu
    Soeda, Tsunenari
    Okayama, Satoshi
    Nishida, Taku
    Takemoto, Yasuhiro
    Onoue, Kenji
    Somekawa, Satoshi
    Takeda, Yukiji
    Kawata, Hiroyuki
    Horii, Manabu
    Saito, Yoshihiko
    CIRCULATION JOURNAL, 2009, 73 (12) : 2300 - 2307
  • [38] Final 5-Year Follow-Up of a Randomized Controlled Trial of Everolimus-and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice The COMPARE Trial (A Trial of Everolimus-Eluting Stents and Paclitaxel Stents for Coronary Revascularization in Daily Practice)
    Smits, Pieter C.
    Vlachojannis, Georgios J.
    McFadden, Eugene Patrick
    Royaards, Kees-Jan
    Wassing, Jochem
    Joesoef, Kaiyum Sheik
    van Mieghem, Carlos
    van de Ent, Martin
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (09) : 1157 - 1165
  • [39] Effects of ticagrelor vs. clopidogrel on neointimal proliferation in paclitaxel-eluting stents implanted in the femoropopliteal district: a randomized pilot study using optical coherence tomography
    Ducci, K. J.
    Liistro, F.
    Angioli, P.
    Porto, I.
    Flasini, G.
    Vergallo, R.
    Bolognese, L.
    EUROPEAN HEART JOURNAL, 2018, 39 : 570 - 570
  • [40] The differences of neointimal coverage among bare-metal stent, zotarolimus-eluting stent and everolimus-eluting stent at 9 Months after implantation using optical coherence tomography in STEMI patents
    Sonoda, K.
    Hata, S.
    Yamasa, T.
    Ikeda, S.
    Maemura, K.
    EUROPEAN HEART JOURNAL, 2013, 34 : 1010 - 1010