Stent Coverage and Neointimal Proliferation in Bare Metal Stents Postdilated With a Paclitaxel-Eluting Balloon Versus Everolimus-Eluting Stents Prospective Randomized Study Using Optical Coherence Tomography at 6-Month Follow-Up

被引:29
|
作者
Poerner, Tudor C. [1 ]
Otto, Sylvia
Gassdorf, Johannes [1 ]
Nitsche, Kristina [1 ]
Janiak, Florian [1 ]
Scheller, Bruno [2 ]
Goebel, Bjoern [1 ]
Jung, Christian [1 ]
Figulla, Hans R. [1 ]
机构
[1] Univ Hosp Jena, Dept Med 1, Div Cardiol, Jena, Germany
[2] Univ Saarland, D-66123 Saarbrucken, Germany
关键词
coronary stenosis; drug-eluting stents; percutaneous coronary intervention; tomography; optical coherence; transluminal coronary balloon dilation; PERCUTANEOUS CORONARY INTERVENTION; DUAL-ANTIPLATELET THERAPY; COATED BALLOON; CONVENTIONAL ANGIOPLASTY; ARTERY-DISEASE; RESTENOSIS; LESIONS; TRIAL; IMPLANTATION; REVASCULARIZATION;
D O I
10.1161/CIRCINTERVENTIONS.113.001146
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-In this randomized trial, strut coverage and neointimal proliferation of a therapy of bare metal stents (BMSs) postdilated with the paclitaxel drug-eluting balloon (DEB) was compared with everolimus drug-eluting stents (DESs) at 6-month follow-up using optical coherence tomography. We hypothesized sufficient stent coverage at follow-up. Methods and Results-A total of 105 lesions in 90 patients were treated with either XIENCE V DES (n=51) or BMS postdilated with the SeQuent Please DEB (n=54). At follow-up, comparable results on the primary optical coherence tomography end point (percentage uncovered struts 5.64+/-9.65% in BMS+DEB versus 4.93+/-9.29% in DES; P=0.366) were found. Thus, BMS+DEB achieved the prespecified noninferiority margin of 5% uncovered struts versus DES (difference between treatment means, 0.71%; one-sided upper 95% confidence interval, 4.14%; noninferiority P=0.04). Optical coherence tomography analysis showed significantly more global neointimal proliferation in the BMS+DEB group (15.7+/-7.8 versus 11.0+/-5.2 mm(3) proliferation volume/cm stent length; P=0.002). No significant focal in-stent stenosis analyzed with angiography (percentage diameter stenosis at follow-up, 22.8+/-11.9 versus 16.9+/-10.4; P=0.014) and optical coherence tomography (peak local area stenosis, 39.5+/-13.8% versus 36.8+/-15.6%; P=0.409) was found. Conclusions-Good stent strut coverage of >94% was found in both therapy groups. Despite greater suppression of global neointimal growth in DES, both DES and BMS+DEB effectively prevented clinically relevant focal restenosis at 6-month follow-up.
引用
收藏
页码:760 / U53
页数:10
相关论文
共 50 条
  • [21] Neointimal coverage of paclitaxel and sirolimus eluting stents in long term follow-up. Optical coherence tomography study
    Kochman, J.
    Pietrasik, A.
    Rdzanek, A.
    Scibisz, A.
    Szmidt, M.
    Pawlak, M.
    Kuszewski, P.
    Opolski, G.
    EUROPEAN HEART JOURNAL, 2008, 29 : 147 - 147
  • [22] Comparison of paclitaxel-eluting vs. everolimus-eluting stents implanted simultaneously in different lesions of the same coronary artery: 12-month follow-up with optical coherence tomography
    de la Torre Hernandez, Jose M.
    Lee, Dae-Hyun
    Garcia-Camarero, Tamara
    Sainz Laso, Fermin
    Zueco, Javier
    EUROINTERVENTION, 2013, 9 (08) : 952 - 958
  • [23] Difference in neointimal coverage on the stent strut between sirolimus- and paclitaxel-eluting stents: optical coherence tomography analysis
    Nasu, K.
    Terashima, M.
    Tsuchikane, E.
    Katoh, O.
    Kinoshita, Y.
    Kimura, M.
    Ehara, M.
    Asakura, Y.
    Asakura, K.
    Suzuki, T.
    EUROPEAN HEART JOURNAL, 2009, 30 : 592 - 593
  • [24] Difference in Neointimal Coverage on the Stent Strut Between Sirolimus- and Paclitaxel-Eluting Stents: Optical Coherence Tomography Analysis
    Nasu, Kenya
    Tsuchikane, Etsuo
    Katoh, Osamu
    Ehara, Mariko
    Kinoshita, Yoshihisa
    Kimura, Masashi
    Rathore, Sudhir
    Terashima, Mitsuyasu
    Suzuki, Takahiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A42 - A42
  • [25] Neointimal Coverage of Everolimus-Eluting Stent at 1, 2 and 3 Months Follow-up: Evaluation by Optical Coherence Tomography
    Shimohama, Takao
    Nishinari, Makoto
    Tojo, Taiki
    Shiono, Takaaki
    Shinagawa, Hisahito
    Kameda, Ryo
    Izumi, Tohru
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B184 - B184
  • [26] Paclitaxel-eluting stents versus everolimus-eluting coronary stents in a diabetic population: two-year follow-up of the TUXEDO-India trial
    Kaul, Upendra
    Bhagwat, Ajit
    Pinto, Brian
    Goel, Praveen K.
    Jagtap, Prashant
    Sathe, Shireesh
    Wander, Gurpreet S.
    Arambam, Priyadarshini
    Bangalore, Sripal
    EUROINTERVENTION, 2017, 13 (10) : 1194 - 1201
  • [27] Comparison of neointimal coverage of biolimus A9 eluting stents and paclitaxel eluting stents using optical coherence tomography at 6 months after implantation
    Mavronasiou, E.
    Karantalis, V.
    Davlouros, P.
    Xanthopoulou, I.
    Nikokiris, G.
    Mitropoulou, G.
    Damelou, A.
    Tsigkas, G.
    Hahalis, G.
    Alexopoulos, D.
    EUROPEAN HEART JOURNAL, 2010, 31 : 995 - 995
  • [28] Neointimal Coverage Of Drug Eluting And Bare Metal Stents In Patients With And Without Diabetes - Optical Coherence Tomography Study
    Pietrasik, Arkadiusz
    Rdzanek, Adam
    Kochman, Janusz
    Pawlak, Maciej
    Scibisz, Anna
    Opolski, Grzegorz
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 204I - 204I
  • [29] Tissue coverage of paclitaxel and sirolimus eluting stents in long term follow-up: Optical coherence tomography study
    Kochman, Janusz
    Pietrasik, Arkadiusz
    Rdzanek, Adam
    Scibisz, Anna
    Pawlak, Maciej
    Filipiak, Krzysztof J.
    Opolski, Grzegorz
    CARDIOLOGY JOURNAL, 2013, 20 (03) : 247 - 253
  • [30] Everolimus-Eluting Stents Showed Most Fully Neointimal Coverage at Bifurcation Lesions Among 4 Kinds of Stents: Optical Coherence Tomography Study
    Yoshimura, Takahiro
    Nishino, Masami
    Okamoto, Naotaka
    Tanaka, Akihiro
    Kikuchi, Atsushi
    Masaki, Takeshi
    Mori, Naoki
    Nakamura, Daisuke
    Lee, Yasuharu
    Taniike, Masayuki
    Makino, Nobuhiko
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Morita, Hisaki
    Tanouchi, Jun
    Yamada, Yoshio
    CIRCULATION, 2011, 124 (21)