Biometric measurement with a commercially available swept-source optical coherence tomography in myopia model species

被引:4
|
作者
Han, Tian [1 ,2 ,3 ,4 ]
Wang, Yuliang [1 ,2 ,3 ,4 ]
Huang, Yangyi [1 ,2 ,3 ,4 ]
Chen, Xun [1 ,2 ,3 ,4 ]
Zhu, Xingxue [1 ,2 ,3 ,4 ]
Shen, Yang [1 ,2 ,3 ,4 ]
Zhou, Xingtao [1 ,2 ,3 ,4 ]
机构
[1] Fudan Univ, Dept Ophthalmol, Eye & ENT Hosp, Shanghai, Peoples R China
[2] Fudan Univ, NHC Key Lab Myopia, Shanghai, Peoples R China
[3] Res Ctr Ophthalmol & Optometry Shanghai, Shanghai, Peoples R China
[4] Shanghai Engn Res Ctr Laser & Autostereoscop 3D V, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Optical coherence tomography (OCT); Biometric measurement; Axial length (AL); Myopia; SCHEMATIC EYE; MOUSE EYE; EMMETROPIZATION; LIGHT;
D O I
10.1016/j.heliyon.2022.e12402
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Biometric parameters play an important role in studies on myopia. This study aimed to explore the application of a commercially available two-dimensional visualized swept-source optical coherence tomography (OCT) system, for in vivo biometric measurement in multiple myopia model species. Methods: In this study, chickens, guinea pigs, and C57BL/6 mice underwent eye imaging with the commercially available OCT (CASIA2), and the original images were used to calculate the central corneal thickness, anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD), and axial length (AL). The retinal thickness and choroidal thickness were also calculated in chicken eyes. The repeatability of the biometric measurement outcomes was analyzed. Results: Excellent repeatable AL measurements were obtained for all three species, with an intraclass correlation coefficient (ICC) of >= 0.941 and a within-subject standard deviation of <= 0.055. Excellent repeatability was found in chicken eyes for ACD, LT, and VCD, with an ICC of >= 0.932; in guinea pig eyes for ACD and VCD, with an ICC of >= 0.934; and in mouse eyes for LT, with an ICC of >= 0.941. Conclusions: It is effective to use commercially available OCT to measure biometric parameters in chickens, guinea pigs, and C57BL/6 mice. This methodology could potentially increase the accuracy and efficiency of future myopia animal experiments.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Evaluation of biometric indicators of anterior segment parameters after ICL implantation by swept-source optical coherence tomography
    Chuhao Tang
    Tong Sun
    Zhengze Sun
    Hongyu Duan
    Yilin Liu
    Lu Zhao
    Wenlong Li
    Linbo Bian
    Hong Qi
    BMC Ophthalmology, 23
  • [42] Measurement of small melanocytic choroidal lesions: Ultrasound versus swept-source optical coherence tomography
    Baradad-Jurjo, Maria C.
    Lorenzo, Daniel
    Vigues-Jorba, Laura
    Caminal, Josep M.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 49 (09): : 1118 - 1121
  • [43] Associated factors for visibility and width of retrobulbar subarachnoid space on swept-source optical coherence tomography in high myopia
    Fan, Hua
    Ma, Hongjie
    Gao, Rulong
    Ng, Danny Siu-Chun
    Cheung, Carol Y.
    Li, Shuangnong
    Wu, Dezheng
    Tang, Shibo
    SCIENTIFIC REPORTS, 2016, 6
  • [44] Retinal curvature in Chinese children with myopia measured by ultra-widefield swept-source optical coherence tomography
    Wu, Hotin
    Zhang, Bo
    Chen, Jun
    Qi, Ziyi
    Xu, Xun
    Li, Huo
    He, Xiangui
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2024,
  • [45] Comparison of Anterior Ocular Biometric Measurements Using Swept-Source and Time-Domain Optical Coherence Tomography
    Chen, Sisi
    Gao, Rongrong
    McAlinden, Colm
    Ye, Junming
    Wang, Yiran
    Chen, Min
    Huang, Jinhai
    Sun, Yong
    Yu, A-Yong
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [46] Comparison of ocular biometric measurements in patients with cataract using three swept-source optical coherence tomography devices
    Oh, Richul
    Oh, Joo Youn
    Choi, Hyuk Jin
    Kim, Mee Kum
    Yoon, Chang Ho
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [47] Comparison of ocular biometric measurements in patients with cataract using three swept-source optical coherence tomography devices
    Richul Oh
    Joo Youn Oh
    Hyuk Jin Choi
    Mee Kum Kim
    Chang Ho Yoon
    BMC Ophthalmology, 21
  • [48] Efficacy of Swept-source Optical Coherence Tomography in Axial Length Measurement for Advanced Cataract Patients
    Chirapapaisan, Chareenun
    Srivannaboon, Sabong
    Chonpimai, Pratuangsri
    OPTOMETRY AND VISION SCIENCE, 2020, 97 (03) : 186 - 191
  • [49] Segmentation Errors in the Measurement of Volumetric Parameters by Swept-Source Anterior Segment Optical Coherence Tomography
    Chen, Hailiu
    Meng, Jie
    Lu, Peng
    Ye, Dan
    Li, Yunxuan
    Cheng, Lu
    Li, Yangyunhui
    Liang, Xiaoling
    Huang, Wenyong
    Huang, Jingjing
    FRONTIERS IN MEDICINE, 2021, 8
  • [50] Three-Dimensional Choroidal Vascularity Index in High Myopia Using Swept-Source Optical Coherence Tomography
    Liu, Lu
    Zhu, Chengcheng
    Yuan, Ying
    Hu, Xiaojun
    Chen, Chaoyue
    Zhu, Hong
    Ke, Bilian
    CURRENT EYE RESEARCH, 2022, 47 (03) : 484 - 492