Biometric measurement with a commercially available swept-source optical coherence tomography in myopia model species

被引:4
|
作者
Han, Tian [1 ,2 ,3 ,4 ]
Wang, Yuliang [1 ,2 ,3 ,4 ]
Huang, Yangyi [1 ,2 ,3 ,4 ]
Chen, Xun [1 ,2 ,3 ,4 ]
Zhu, Xingxue [1 ,2 ,3 ,4 ]
Shen, Yang [1 ,2 ,3 ,4 ]
Zhou, Xingtao [1 ,2 ,3 ,4 ]
机构
[1] Fudan Univ, Dept Ophthalmol, Eye & ENT Hosp, Shanghai, Peoples R China
[2] Fudan Univ, NHC Key Lab Myopia, Shanghai, Peoples R China
[3] Res Ctr Ophthalmol & Optometry Shanghai, Shanghai, Peoples R China
[4] Shanghai Engn Res Ctr Laser & Autostereoscop 3D V, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Optical coherence tomography (OCT); Biometric measurement; Axial length (AL); Myopia; SCHEMATIC EYE; MOUSE EYE; EMMETROPIZATION; LIGHT;
D O I
10.1016/j.heliyon.2022.e12402
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Biometric parameters play an important role in studies on myopia. This study aimed to explore the application of a commercially available two-dimensional visualized swept-source optical coherence tomography (OCT) system, for in vivo biometric measurement in multiple myopia model species. Methods: In this study, chickens, guinea pigs, and C57BL/6 mice underwent eye imaging with the commercially available OCT (CASIA2), and the original images were used to calculate the central corneal thickness, anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD), and axial length (AL). The retinal thickness and choroidal thickness were also calculated in chicken eyes. The repeatability of the biometric measurement outcomes was analyzed. Results: Excellent repeatable AL measurements were obtained for all three species, with an intraclass correlation coefficient (ICC) of >= 0.941 and a within-subject standard deviation of <= 0.055. Excellent repeatability was found in chicken eyes for ACD, LT, and VCD, with an ICC of >= 0.932; in guinea pig eyes for ACD and VCD, with an ICC of >= 0.934; and in mouse eyes for LT, with an ICC of >= 0.941. Conclusions: It is effective to use commercially available OCT to measure biometric parameters in chickens, guinea pigs, and C57BL/6 mice. This methodology could potentially increase the accuracy and efficiency of future myopia animal experiments.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Evaluation of choroidal lesions with swept-source optical coherence tomography
    Ung, Cindy
    Lains, Ines
    Silverman, Rebecca F.
    Woods, Russell
    Lane, Anne Marie
    Papakostas, Thanos D.
    Husain, Deeba
    Miller, Joan W.
    Gragoudas, Evangelos S.
    Kim, Ivana K.
    Miller, John B.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (01) : 88 - 93
  • [32] Swept-source optical coherence tomography in a retinal astrocytic hamartoma
    Bastons-Compta, C.
    Moix-Gil, E.
    Huanca, H. G.
    Baradad, M. C.
    Lorenzo, D.
    Caminal, J. M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2020, 43 (07): : 683 - 686
  • [33] Cataract quantification using swept-source optical coherence tomography
    Panthier, Christophe
    Saad, Main
    Rouger, Helene
    Gatinel, Damien
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 893 - 894
  • [34] The effect of cycloplegia on biometric measurements using swept-source optical coherence tomography-based biometry
    Ozcaliskan, Sehnaz
    Yenerel, Nursal Melda
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2019, 102 (05) : 501 - 505
  • [35] The Latest Updates in Swept-Source Optical Coherence Tomography Angiography
    Xia, Fan
    Hua, Rui
    DIAGNOSTICS, 2024, 14 (01)
  • [36] Choroidal thickness in the era of swept-source optical coherence tomography
    Agarwal, Aniruddha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (02) : 256 - 257
  • [37] Swept-source optical coherence tomography imaging of the retinochoroid and beyond
    Vira, Jayesh
    Marchese, Alessandro
    Singh, Rohan Bir
    Agarwal, Aniruddha
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (05) : 413 - 426
  • [38] Swept-source optical coherence tomography findings in peripheral drusen
    Kumar, Vinod
    Tewari, Ruchir
    Chandra, Parijat
    Kumar, Atul
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (12) : 930 - 931
  • [39] Stabilizing the phase of swept-source optical coherence tomography by a wrapped Gaussian mixture model
    Wei, Shuwen
    Kang, Jin U.
    OPTICS LETTERS, 2021, 46 (12) : 2932 - 2935
  • [40] Evaluation of biometric indicators of anterior segment parameters after ICL implantation by swept-source optical coherence tomography
    Tang, Chuhao
    Sun, Tong
    Sun, Zhengze
    Duan, Hongyu
    Liu, Yilin
    Zhao, Lu
    Li, Wenlong
    Bian, Linbo
    Qi, Hong
    BMC OPHTHALMOLOGY, 2023, 23 (01)