Determination of levocetirizine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study

被引:24
|
作者
Morita, M. R. [1 ,2 ]
Berton, D. [1 ]
Boldin, R. [1 ]
Barros, F. A. P. [1 ]
Meurer, E. C. [1 ]
Amarante, A. R.
Campos, D. R. [2 ]
Calafatti, S. A. [1 ]
Pereira, R.
Abib, E., Jr. [2 ]
Pedrazolli, J., Jr. [1 ,2 ]
机构
[1] Core Clin Res, BR-12914160 Braganca Paulista, SP, Brazil
[2] FCM UNICAMP, Campinas, SP, Brazil
关键词
mass spectrometry; bioavailability; levocetirizine;
D O I
10.1016/j.jchromb.2007.11.028
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe a liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for levocetirizine quantification (I) in human plasma. Sample preparation was made using a fexofenadine (H) addition as internal standard (IS), liquid-liquid extraction using cold dichloromethane, and dissolving the final extract in acetonitrile. I and II (IS) were injected in a C18 column and the mobile phase composed of acetonitrile:water:formic acid (80.00:19.90:0.10, v/v/v) and monitored using positive electrospray source with tandem mass spectrometry analyses. The selected reaction monitoring (SRM) was set using precursor ion and product ion combinations of m/z 389 > 201 forI and m/z 502 > 467 for II. The limit of quantification and the dynamic range achieved were 0.5 ng/mL and 0.5-500.0 ng/mL. Validation results on linearity, specificity, accuracy, precision and stability, as well as its application to the analysis of plasma samples taken up to 48 h after oral administration of 5 mg of levocetirizine dichloridrate in healthy volunteers demonstrate its applicability to bioavailability studies. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:132 / 139
页数:8
相关论文
共 50 条
  • [41] Validation of a Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry Method for Determination of All-Trans Retinoic Acid in Human Plasma and Its Application to a Bioequivalence Study
    Peng, Jing-Bo
    Luo, Chen-Hui
    Wang, Yi-Cheng
    Huang, Wei-Hua
    Chen, Yao
    Zhou, Hong-Hao
    Tan, Zhi-Rong
    [J]. MOLECULES, 2014, 19 (01) : 1189 - 1200
  • [42] Ultrafast liquid chromatography-tandem mass spectrometry determination of donepezil in human plasma: application to a bioequivalence study
    Huang, Yan-Wen
    Ding, Li
    Chen, Yuan-Ming
    Lin, Wei-chen
    Lin, Fei
    Hsieh, Yunsheng
    [J]. TRANSLATIONAL AND CLINICAL PHARMACOLOGY, 2022, 30 (01) : 37 - 48
  • [43] RAPID DETERMINATION OF CANDESARTAN IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY AND ITS APPLICATION TO A BIOEQUIVALENCE STUDY
    Lou, Hong-gang
    Ruan, Zou-rong
    Jiang, Bo
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (08) : 1027 - 1037
  • [44] QUANTITATIVE DETERMINATION OF MEMANTINE IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY: APPLICATION TO A BIOEQUIVALENCE STUDY
    Lou, Hong-gang
    Yu, Ling-yan
    Ruan, Zou-Rong
    Jiang, Bo
    Chen, Jin-liang
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (19) : 2696 - 2705
  • [45] Application of a rapid and selective method for the simultaneous determination of carebastine and pseudoephedrine in human plasma by liquid chromatography-electrospray mass spectrometry for bioequivalence study in Korean subjects
    Lee, Myung-Jae
    Lee, Heon-Woo
    Kang, Jong-Min
    Seo, Ji-Hyung
    Tak, Seong-Kun
    Shim, Wangseob
    Yim, Sung-Vin
    Hong, Seung Jae
    Lee, Kyung-Tae
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (10) : 1031 - 1037
  • [46] Determination of finasteride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry with flow rate gradient
    Yuan, Lihua
    Ding, Meijuan
    Ma, Jing
    Xu, Jinhui
    Wu, Xiaoli
    Feng, Jing
    Shen, Fei
    Zhou, Xuemin
    [J]. EUROPEAN JOURNAL OF DRUG METABOLISM AND PHARMACOKINETICS, 2011, 35 (3-4) : 137 - 146
  • [47] Liquid chromatography-electrospray mass spectrometry and tandem mass spectrometry of ceramides
    Raith, K
    Neubert, RHH
    [J]. ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) : 295 - 303
  • [48] Liquid chromatography-electrospray lonization tandem mass spectrometric determination of lornoxicam in human plasma
    Young Hoon Kim
    Hye Young Ji
    Eun -Seok Park
    Soo -Wan Chae
    Hye Suk Lee
    [J]. Archives of Pharmacal Research, 2007, 30 : 905 - 910
  • [49] Liquid chromatography-electrospray ionization tandem mass spectrometric determination of lornoxicam in human plasma
    Kim, Young Hoon
    Ji, Hye Young
    Park, Eun-Seok
    Chae, Soo-Wan
    Lee, Hye Suk
    [J]. ARCHIVES OF PHARMACAL RESEARCH, 2007, 30 (07) : 905 - 910
  • [50] LIQUID CHROMATOGRAPHY-ELECTROSPRAY TANDEM MASS SPECTROMETRY (LC-MS/MS) DETERMINATION OF LANSOPRAZOLE IN HUMAN PLASMA
    Ganesh, M.
    BhagiyaLakshmi, M.
    Hemalatha, P.
    Patil, Rahul
    Sakthimanigandan, K.
    Jang, Hyun Tae
    Rajasekar, K.
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (02) : 129 - 142