Determination of levocetirizine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study

被引:24
|
作者
Morita, M. R. [1 ,2 ]
Berton, D. [1 ]
Boldin, R. [1 ]
Barros, F. A. P. [1 ]
Meurer, E. C. [1 ]
Amarante, A. R.
Campos, D. R. [2 ]
Calafatti, S. A. [1 ]
Pereira, R.
Abib, E., Jr. [2 ]
Pedrazolli, J., Jr. [1 ,2 ]
机构
[1] Core Clin Res, BR-12914160 Braganca Paulista, SP, Brazil
[2] FCM UNICAMP, Campinas, SP, Brazil
关键词
mass spectrometry; bioavailability; levocetirizine;
D O I
10.1016/j.jchromb.2007.11.028
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe a liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for levocetirizine quantification (I) in human plasma. Sample preparation was made using a fexofenadine (H) addition as internal standard (IS), liquid-liquid extraction using cold dichloromethane, and dissolving the final extract in acetonitrile. I and II (IS) were injected in a C18 column and the mobile phase composed of acetonitrile:water:formic acid (80.00:19.90:0.10, v/v/v) and monitored using positive electrospray source with tandem mass spectrometry analyses. The selected reaction monitoring (SRM) was set using precursor ion and product ion combinations of m/z 389 > 201 forI and m/z 502 > 467 for II. The limit of quantification and the dynamic range achieved were 0.5 ng/mL and 0.5-500.0 ng/mL. Validation results on linearity, specificity, accuracy, precision and stability, as well as its application to the analysis of plasma samples taken up to 48 h after oral administration of 5 mg of levocetirizine dichloridrate in healthy volunteers demonstrate its applicability to bioavailability studies. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:132 / 139
页数:8
相关论文
共 50 条
  • [31] Quantitative Determination of Pidotimod in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry: Application to a Bioequivalence Study
    Lou, H. -G.
    Ruan, Z. -R.
    Jiang, B.
    [J]. ARZNEIMITTEL-FORSCHUNG-DRUG RESEARCH, 2012, 62 (02): : 99 - 104
  • [32] Quantitative determination of armodafinil in human plasma by liquid chromatography-electrospray mass spectrometry: Application to a clinical study
    Chandasana, Hardik
    Kast, Johannes
    Bittman, Janina A.
    Derendorf, Hartmut
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (11)
  • [33] A rapid, simple and sensitive method for the determination and bioequivalence study of transdermal fentanyl in human plasma using liquid chromatography-electrospray ionization tandem mass spectrometry
    Cheng, Shu-Qiao
    Ouyang, Dong-Sheng
    Tang, Yong-Jun
    Wu, Kai
    Xiao, Jian
    [J]. INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2016, 54 (02) : 144 - 156
  • [34] Simultaneous determination of donepezil (aricept®) enantiomers in human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Matsui, K
    Oda, Y
    Nakata, H
    Yoshimura, T
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 729 (1-2): : 147 - 155
  • [35] Simultaneous determination of azilsartan and chlorthalidone in rat and human plasma by liquid chromatography-electrospray tandem mass spectrometry
    Ramakrishna, Rachumallu
    Puttrevu, Santosh Kumar
    Bhateria, Manisha
    Bala, Veenu
    Sharma, Vishnu L.
    Bhatta, Rabi Sankar
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 990 : 185 - 197
  • [36] Determination of zaltoprofen in human plasma by liquid chromatography with electrospray tandem mass spectrometry: application to a pharmacokinetic study
    Lee, Heon-Woo
    Seo, Ji-Hyung
    Kim, Yong-Won
    Jeong, Seo-Young
    Lee, Kyung-Tae
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (18) : 2675 - 2680
  • [37] Determination of tetrabromobisphenol A in human serum by liquid chromatography-electrospray ionization tandem mass spectrometry
    Hayama, T
    Yoshida, H
    Onimaru, S
    Yonekura, S
    Kuroki, H
    Todoroki, K
    Nohta, H
    Yamaguchi, M
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (01): : 131 - 136
  • [38] Quantification of zolpidem in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Bhatt, Jignesh
    Jangid, Arvind
    Shetty, Raghavendra
    Shah, Bhavin
    Kambli, Sandeep
    Subbaiah, Gunta
    Singh, Sadhana
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (08) : 736 - 742
  • [39] Determination of cortisol in human saliva using liquid chromatography-electrospray tandem mass spectrometry
    Jönsson, BAG
    Malmberg, B
    Amilon, A
    Garde, AH
    Orbæk, P
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 784 (01): : 63 - 68
  • [40] Quantification of voriconazole in human plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry: application to a bioequivalence study
    Cheng, Ying
    Zhang, Zun-Jian
    Tian, Yuan
    Li, Wen-Jing
    Wei, Wei
    [J]. ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2011, 61 (02): : 132 - 139