Validation of a Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry Method for Determination of All-Trans Retinoic Acid in Human Plasma and Its Application to a Bioequivalence Study

被引:9
|
作者
Peng, Jing-Bo [1 ]
Luo, Chen-Hui [2 ]
Wang, Yi-Cheng [1 ]
Huang, Wei-Hua [1 ]
Chen, Yao [1 ]
Zhou, Hong-Hao [1 ]
Tan, Zhi-Rong [1 ]
机构
[1] Cent S Univ, Inst Clin Pharmacol, Changsha 410078, Hunan, Peoples R China
[2] Cent S Univ, Affiliated Tumor Hosp, Xiangya Med Sch, Hunan Prov Tumor Hosp, Changsha 410013, Hunan, Peoples R China
基金
中国博士后科学基金;
关键词
all-trans retinoic acid (ATRA); LC-MS-MS; liquid-liquid extraction; bioequivalence; ACUTE PROMYELOCYTIC LEUKEMIA; QUANTIFICATION; METABOLISM; 9-CIS;
D O I
10.3390/molecules19011189
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive, reliable and specific LC-MS-MS method was developed and validated for the identification and quantitation of all-trans retinoic acid (ATRA) in human plasma. Acitretin was used as the internal standard (IS). After liquid-liquid extraction of 500 mu L plasma with methyl tert-butyl ether (MTBE), ATRA and the IS were chromatographed on a HyPURITY C18 column (150 mm x 2.1 mm, 5 mu m) with the column temperature set at 40 degrees C. The mobile phase was consisted of 40% phase A (MTBE-methanol-acetic acid, 50:50:0.5, v/v) and 60% phase B (water-methanol-acetic acid, 50: 50: 0.5, v/v) with a flow rate of 0.3 mL/min. The API 4000 triple quadrupole mass spectrometer was operated in multiple reaction monitoring (MRM) mode via the positive electrospray ionization interface using the transition m/z 301.4 -> 123.1 for ATRA and m/z 326.9 -> 177.1 for IS, respectively. The calibration curve was linear over the range of 0.45-217.00 ng/mL (r >= 0.999) with a lower limit of quantitation (LLOQ) of 0.45 ng/mL. The intra- and inter-day precisions values were below 8% relative standard deviation and the accuracy was from 98.98% to 106.19% in terms of relative error. The validated method was successfully applied in a bioequivalence study of ATRA in Chinese healthy volunteers.
引用
收藏
页码:1189 / 1200
页数:12
相关论文
共 50 条
  • [1] Determination of cymipristone in human plasma by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Jiang, Bo
    Ruan, Zourong
    Lou, Honggang
    Yuan, Hong
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (7-8): : 719 - 723
  • [2] Determination of bevantolol in human plasma using liquid chromatography-electrospray ionization tandem mass spectrometry and its application to a bioequivalence study
    Ren, Li
    Wang, Zheng
    Lou, Yiceng
    Zheng, Lu
    Zheng, Heng
    Yin, Chunping
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 959 : 16 - 21
  • [3] Development and validation of a liquid chromatography-electrospray ionization-tandem mass spectrometry method for the determination of urolithin C in rat plasma and its application to a pharmacokinetic study
    Bayle, Morgane
    Rogues, Celine
    Marion, Benedicte
    Audran, Michel
    Oiry, Catherine
    Bressolle-Gomeni, Francoise M. M.
    Cros, Gerard
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 131 : 33 - 39
  • [4] Determination of levocetirizine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study
    Morita, M. R.
    Berton, D.
    Boldin, R.
    Barros, F. A. P.
    Meurer, E. C.
    Amarante, A. R.
    Campos, D. R.
    Calafatti, S. A.
    Pereira, R.
    Abib, E., Jr.
    Pedrazolli, J., Jr.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 132 - 139
  • [5] Determination of memantine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study
    Almeida, A. A.
    Campos, D. R.
    Bernasconi, G.
    Calafatti, S.
    Barros, F. A. P.
    Eberlin, M. N.
    Meurer, E. C.
    Paris, E. G.
    Pedrazzoli, J.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 848 (02): : 311 - 316
  • [6] A Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry Method for Quantitation of Aripiprazole in Human Plasma
    Lin, Shen-Nan
    Lamm, Lolita
    Newton, Thomas F.
    Reid, Malcolm S.
    Moody, David E.
    Foltz, Rodger L.
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2009, 33 (05) : 237 - 242
  • [7] Validated method for determination of bromopride in human plasma by liquid chromatography-electrospray tandem mass spectrometry: application to the bioequivalence study
    Nazare, P
    Massaroti, P
    Duarte, LF
    Campos, DR
    Marchioretto, MAM
    Bernasconi, G
    Calafatti, S
    Barros, FAP
    Meurer, EC
    Pedrazzoli, J
    Moraes, LAB
    [J]. JOURNAL OF MASS SPECTROMETRY, 2005, 40 (09): : 1197 - 1202
  • [8] CREATININE DETERMINATION IN URINE BY LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION-TANDEM MASS SPECTROMETRY METHOD
    Derezinski, Pawel
    Klupczynska, Agnieszka
    Sawicki, Wojciech
    Kokot, Zenon J.
    [J]. ACTA POLONIAE PHARMACEUTICA, 2016, 73 (02): : 303 - 313
  • [10] Determination of carotenoids and all-trans-retinol in fish eggs by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Li, HX
    Tyndale, ST
    Heath, DD
    Letcher, RJ
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 49 - 56