Validation of a Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry Method for Determination of All-Trans Retinoic Acid in Human Plasma and Its Application to a Bioequivalence Study

被引:9
|
作者
Peng, Jing-Bo [1 ]
Luo, Chen-Hui [2 ]
Wang, Yi-Cheng [1 ]
Huang, Wei-Hua [1 ]
Chen, Yao [1 ]
Zhou, Hong-Hao [1 ]
Tan, Zhi-Rong [1 ]
机构
[1] Cent S Univ, Inst Clin Pharmacol, Changsha 410078, Hunan, Peoples R China
[2] Cent S Univ, Affiliated Tumor Hosp, Xiangya Med Sch, Hunan Prov Tumor Hosp, Changsha 410013, Hunan, Peoples R China
基金
中国博士后科学基金;
关键词
all-trans retinoic acid (ATRA); LC-MS-MS; liquid-liquid extraction; bioequivalence; ACUTE PROMYELOCYTIC LEUKEMIA; QUANTIFICATION; METABOLISM; 9-CIS;
D O I
10.3390/molecules19011189
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive, reliable and specific LC-MS-MS method was developed and validated for the identification and quantitation of all-trans retinoic acid (ATRA) in human plasma. Acitretin was used as the internal standard (IS). After liquid-liquid extraction of 500 mu L plasma with methyl tert-butyl ether (MTBE), ATRA and the IS were chromatographed on a HyPURITY C18 column (150 mm x 2.1 mm, 5 mu m) with the column temperature set at 40 degrees C. The mobile phase was consisted of 40% phase A (MTBE-methanol-acetic acid, 50:50:0.5, v/v) and 60% phase B (water-methanol-acetic acid, 50: 50: 0.5, v/v) with a flow rate of 0.3 mL/min. The API 4000 triple quadrupole mass spectrometer was operated in multiple reaction monitoring (MRM) mode via the positive electrospray ionization interface using the transition m/z 301.4 -> 123.1 for ATRA and m/z 326.9 -> 177.1 for IS, respectively. The calibration curve was linear over the range of 0.45-217.00 ng/mL (r >= 0.999) with a lower limit of quantitation (LLOQ) of 0.45 ng/mL. The intra- and inter-day precisions values were below 8% relative standard deviation and the accuracy was from 98.98% to 106.19% in terms of relative error. The validated method was successfully applied in a bioequivalence study of ATRA in Chinese healthy volunteers.
引用
下载
收藏
页码:1189 / 1200
页数:12
相关论文
共 50 条
  • [31] Liquid chromatography-electrospray ionization-tandem mass spectrometry for simultaneous analysis of chlorogenic acids and their metabolites in human plasma
    Matsui, Yuji
    Nakamura, Shun
    Kondou, Naoki
    Takasu, Yoshio
    Ochiai, Ryuji
    Masukawa, Yoshinori
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 858 (1-2): : 96 - 105
  • [32] Liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry for Simultaneous Determination of Metformin and Glimepiride in Beagle Dog Plasma and Bioequivalence Study
    Bai Jing
    Shi Xiao-wei
    Du Ying-feng
    Xiang Bai
    Wang Shuai
    Cao De-ying
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2012, 28 (03) : 399 - 405
  • [33] Liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry for Simultaneous Determination of Metformin and Glimepiride in Beagle Dog Plasma and Bioequivalence Study
    BAI Jing 1
    2.Department of Pharmacy
    Chemical Research in Chinese Universities, 2012, 28 (03) : 399 - 405
  • [34] Development and validation of highly sensitive method for determination of misoprostol free acid in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry: Application to a clinical pharmacokinetic study
    Bharathi, D. Vijaya
    Jagadeesh, B.
    Hotha, Kishore Kumar
    Patil, Uday
    Bhushan, Indu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (26): : 2827 - 2833
  • [35] Determination of levetiracetam in human plasma by liquid chromatography/electrospray tandem mass spectrometry and its application to bioequivalence studies
    Jain, Deepak S.
    Subbaiah, Gunta
    Sanyal, Mallika
    Pal, Usha
    Shrivastav, Pranav S.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (17) : 2539 - 2547
  • [36] Determination of lansoprazole in human plasma by rapid resolution liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study on Chinese volunteers
    Wu, Guo-Lan
    Zhou, Hui-Li
    Shentu, Jian-Zhong
    He, Qiao-Jun
    Yang, Bo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (05) : 1485 - 1489
  • [37] Highly sensitive method for the determination of omeprazole in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry: application to a clinical pharmacokinetic study
    Vittal, Shivva
    Ganneboina, Ramesh
    Layek, Buddhadev
    Trivedi, Ravi Kumar
    Hotha, Kishore Kumar
    Bharathi, D. Vijaya
    Mullangi, Ramesh
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (04) : 390 - 396
  • [38] Rapid determination of total homocysteine in blood spots by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Gempel, K
    Gerbitz, KD
    Casetta, B
    Bauer, MF
    CLINICAL CHEMISTRY, 2000, 46 (01) : 122 - 123
  • [39] Quantitative determination of dihydrostreptomycin in bovine tissues and milk by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Cherlet, Marc
    De Baere, Siegrid
    De Backer, Patrick
    JOURNAL OF MASS SPECTROMETRY, 2007, 42 (05): : 647 - 656
  • [40] Determination of clindamycin in human plasma by liquid chromatography electrospray tandem mass spectrometry: application to the bioequivalence study of clindamycin
    Yu, LL
    Chao, CK
    Liao, WJ
    Twu, TY
    Liu, CM
    Yang, TH
    Lin, ET
    JOURNAL OF CHROMATOGRAPHY B, 1999, 724 (02): : 287 - 294