Strut apposition after coronary stent implantation visualised with optical coherence tomography

被引:1
|
作者
Radu, Maria [1 ]
Jorgensen, Erik [1 ]
Kelbaek, Henning [1 ]
Helqvist, Steffen [1 ]
Skovgaard, Lene [2 ]
Saunamaki, Karl [1 ]
机构
[1] Univ Copenhagen, Ctr Heart, Dept Cardiol, Rigshosp, DK-2100 Copenhagen, Denmark
[2] Univ Copenhagen, Dept Biostat, DK-2100 Copenhagen, Denmark
关键词
OCT; strut apposition; stent implantation; invasive imaging; INTRAVASCULAR ULTRASOUND ANALYSIS; INTRACORONARY ULTRASOUND; NEOINTIMAL COVERAGE; ELUTING STENTS; THROMBOSIS;
D O I
10.4244/EIJV6I1A13
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To describe different patterns of stent strut apposition, as visualised with optical coherence tomography. Methods and results: Strut thicknesses were reconstructed according to the manufacturers' specifications. The stent area (SA) was measured by connecting the reconstructed abluminal surfaces of struts with a trace line, and the vessel wall area (VWA) was estimated from the abluminal strut surfaces, as well as from the lumen border, in cases of struts that were separated from the vessel wall by flush. Strut apposition was evaluated by comparing the SA- and VWA traces. We observed four patterns of strut apposition. Based on these, stent struts could be classified as: (I) apposed struts, (II) struts overlying the ostium of a side branch, (Ill) malapposed struts that were clearly separated from the vessel wall by flush, and (IV) pseudoapposed struts that were not separated from the vessel wall by visual estimate, but were malapposed in the sense that SA<VWA. Pseudoapposed struts were found in frames with "flower-shaped" lumen contours, and were often surrounded by structures of a lower signal intensity than the rest of the vessel wall. Conclusions: For a detailed analysis of strut apposition with OCT, we reconstructed strut thicknesses and estimated stent- and vessel wall areas. With this method, we found four types of strut apposition, where pseudoapposed struts constitute a type of struts not previously described. The clinical importance of pseudoapposed struts remains to be settled.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 50 条
  • [41] Incidence and Significance of the Pseudo Stent Strut in Optical Coherence Tomography Analysis for Coronary Artery Stents
    Suzuki, Nobuaki
    Kozuma, Ken
    Hatsuno, Taketo
    Takada, Kaoru
    Iino, Ryu
    Maeno, Yoshio
    Yamamoto, Hirosada
    Shiratori, Yoshitaka
    Ishikawa, Shuichi
    Miyazawa, Akiyoshi
    Isshiki, Takaaki
    [J]. PHOTONIC THERAPEUTICS AND DIAGNOSTICS VI, 2010, 7548
  • [42] Usefulness of optical coherence tomography with angiographic coregistration in the guidance of coronary stent implantation
    Takashi Kubo
    Yasushi Ino
    Yasutsugu Shiono
    Kosei Terada
    Hiroki Emori
    Daisuke Higashioka
    Masahiro Takahata
    Teruaki Wada
    Kunihiro Shimamura
    Amir Kh. M. Khalifa
    Shengxian Tu
    Takashi Akasaka
    [J]. Heart and Vessels, 2022, 37 : 200 - 207
  • [43] Usefulness of optical coherence tomography with angiographic coregistration in the guidance of coronary stent implantation
    Kubo, Takashi
    Ino, Yasushi
    Shiono, Yasutsugu
    Terada, Kosei
    Emori, Hiroki
    Higashioka, Daisuke
    Takahata, Masahiro
    Wada, Teruaki
    Shimamura, Kunihiro
    Khalifa, Amir Kh. M.
    Tu, Shengxian
    Akasaka, Takashi
    [J]. HEART AND VESSELS, 2022, 37 (02) : 200 - 207
  • [44] Can Angiographic Late Loss Predict the Neointimal Coverage Of Stent Strut On Optical Coherence Tomography After Drug-eluting Stent Implantation?
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Hong, Myeong-Ki
    Jang, Yangsoo
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (13) : B14 - B14
  • [45] Optical Coherence Tomography Imaging of Acute Stent Thrombosis After Stentys Stent Implantation
    Timmers, Leo
    Belkacemi, Anouar
    Agostoni, Pierfrancesco
    Stella, Pieter R.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (17) : 1752 - 1752
  • [46] The Relationship Between Post-Stent Strut Apposition and Follow-Up Strut Coverage Assessed by a Contour Plot Optical Coherence Tomography Analysis
    Kim, Jung-Sun
    Ha, Jinyong
    Kim, Byeong-Keuk
    Shin, Dong-Ho
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (06) : 641 - 651
  • [47] Assessment of strut coverage of everolimus-eluting platinum chromium stent 2 weeks after implantation by optical coherence tomography
    Oka, Norikiyo
    Fujii, Kenichi
    Kadohira, Tadayuki
    Kitahara, Hideki
    Fujimoto, Yoshihide
    Takahara, Masayuki
    Himi, Toshiharu
    Ishikawa, Keishi
    Sano, Koichi
    Kobayashi, Yoshio
    [J]. HEART AND VESSELS, 2019, 34 (08) : 1258 - 1265
  • [48] Impact of stent strut thickness on arterial healing after drug-eluting stents implantation assessed by optical coherence tomography
    Tada, T.
    Byrne, R. A.
    Dimopoulos, A.
    King, L.
    Li, Y.
    Joner, M.
    Kastrati, A.
    [J]. EUROPEAN HEART JOURNAL, 2013, 34 : 705 - 705
  • [49] Assessment of strut coverage of everolimus-eluting platinum chromium stent 2 weeks after implantation by optical coherence tomography
    Norikiyo Oka
    Kenichi Fujii
    Tadayuki Kadohira
    Hideki Kitahara
    Yoshihide Fujimoto
    Masayuki Takahara
    Toshiharu Himi
    Keishi Ishikawa
    Koichi Sano
    Yoshio Kobayashi
    [J]. Heart and Vessels, 2019, 34 : 1258 - 1265
  • [50] Initial findings of impact of strut width on stent coverage and apposition of sirolimus-eluting stents assessed by optical coherence tomography
    Nakatani, Shimpei
    Nishino, Masami
    Taniike, Masayuki
    Makino, Nobuhiko
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Tanouchi, Jun
    Yamada, Yoshio
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) : 776 - 781