Strut apposition after coronary stent implantation visualised with optical coherence tomography

被引:2
|
作者
Radu, Maria [1 ]
Jorgensen, Erik [1 ]
Kelbaek, Henning [1 ]
Helqvist, Steffen [1 ]
Skovgaard, Lene [2 ]
Saunamaki, Karl [1 ]
机构
[1] Univ Copenhagen, Ctr Heart, Dept Cardiol, Rigshosp, DK-2100 Copenhagen, Denmark
[2] Univ Copenhagen, Dept Biostat, DK-2100 Copenhagen, Denmark
关键词
OCT; strut apposition; stent implantation; invasive imaging; INTRAVASCULAR ULTRASOUND ANALYSIS; INTRACORONARY ULTRASOUND; NEOINTIMAL COVERAGE; ELUTING STENTS; THROMBOSIS;
D O I
10.4244/EIJV6I1A13
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To describe different patterns of stent strut apposition, as visualised with optical coherence tomography. Methods and results: Strut thicknesses were reconstructed according to the manufacturers' specifications. The stent area (SA) was measured by connecting the reconstructed abluminal surfaces of struts with a trace line, and the vessel wall area (VWA) was estimated from the abluminal strut surfaces, as well as from the lumen border, in cases of struts that were separated from the vessel wall by flush. Strut apposition was evaluated by comparing the SA- and VWA traces. We observed four patterns of strut apposition. Based on these, stent struts could be classified as: (I) apposed struts, (II) struts overlying the ostium of a side branch, (Ill) malapposed struts that were clearly separated from the vessel wall by flush, and (IV) pseudoapposed struts that were not separated from the vessel wall by visual estimate, but were malapposed in the sense that SA<VWA. Pseudoapposed struts were found in frames with "flower-shaped" lumen contours, and were often surrounded by structures of a lower signal intensity than the rest of the vessel wall. Conclusions: For a detailed analysis of strut apposition with OCT, we reconstructed strut thicknesses and estimated stent- and vessel wall areas. With this method, we found four types of strut apposition, where pseudoapposed struts constitute a type of struts not previously described. The clinical importance of pseudoapposed struts remains to be settled.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 50 条
  • [31] Optical coherence tomography-based evaluation of malapposed strut coverage after drug-eluting stent implantation
    Byeong-Keuk Kim
    Dong-Ho Shin
    Jung-Sun Kim
    Young-Guk Ko
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1887 - 1894
  • [32] 3 DIMENSIONAL OPTICAL COHERENCE TOMOGRAPHY ASSESSMENT OF STRUT COVERAGE AND INTRALUMINAL MICROSTRUCTURE AFTER EVEROLIMUS ELUTING STENT IMPLANTATION
    Maeda, Takao
    Okamura, Takayuki
    Yamada, Jutaro
    Nao, Tomoko
    Suetomi, Takeshi
    Yoshimura, Masayuki
    Hino, Akihiro
    Oda, Takamasa
    Nakashima, Tadaaki
    Shiraishi, Kouzo
    Nakashima, Tadamitsu
    Nakamura, Takeshi
    Nishimura, Shigehiko
    Miura, Toshiro
    Matsuzaki, Masunori
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E162 - E162
  • [33] Optical coherence tomography-based evaluation of malapposed strut coverage after drug-eluting stent implantation
    Kim, Byeong-Keuk
    Shin, Dong-Ho
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (08): : 1887 - 1894
  • [34] Strut Level Optical Coherence Tomography Evaluation of Coronary Stent Strut Coverage Temporal Trends: A Systematic Review
    Lee, Kwan S.
    Lee, Justin Z.
    Riaz, Irbaz B.
    Husnain, Muhammad
    Riaz, Haris
    Lotun, Kapil
    Kern, Karl B.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B255 - B256
  • [35] An Optical Coherence Tomography Assessment of Stent Strut Apposition Based on the Presence of Lipid-Rich Plaque in the Carotid Artery
    Liu, Rui
    Jiang, Yongjun
    Xiong, Yunyun
    Li, Min
    Ma, Minmin
    Zhu, Wusheng
    Yin, Qin
    Li, Wei
    Xu, Gelin
    Liu, Xinfeng
    JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (06) : 942 - 949
  • [36] Validation Study of an Automated Algorithm to Assess Stent Strut Apposition and Neointima Coverage of In-vivo Intra-Coronary Optical Coherence Tomography Images
    Adriaenssens, Tom
    Ughl, Gtovanni
    Onsea, Kevin
    Kayaert, Peter
    Dubots, Christophe
    Sinnaeve, Peter
    Coosemans, Mark
    Dhooge, Jan
    Desmet, Walter
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (13) : B14 - B14
  • [37] Natural History of Stent Edge Dissection, Tissue Protrusion and Incomplete Stent Apposition Detectable Only on Optical Coherence Tomography After Stent Implantation - Preliminary Observation
    Kume, Teruyoshi
    Okura, Hiroyuki
    Miyamoto, Yoshinori
    Yamada, Ryotaro
    Saito, Ken
    Tamada, Tomoko
    Koyama, Terumasa
    Neishi, Yoji
    Hayashida, Akihiro
    Kawamoto, Takahiro
    Yoshida, Kiyoshi
    CIRCULATION JOURNAL, 2012, 76 (03) : 698 - 703
  • [38] Accuracy of measurement of stent strut thickness by optical coherence tomography
    Terashima, Mitsuyasu
    Nakayama, Yoshiaki
    Suzuki, Yasuyoshi
    Katoh, Osamu
    Suzuki, Takahiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : B53 - B53
  • [39] Accuracy of measurement of stent strut thickness by optical coherence tomography
    Terashima, M.
    Nakayama, Y.
    Suzuki, Y.
    Habara, M.
    Katoh, O.
    Suzuki, T.
    EUROPEAN HEART JOURNAL, 2008, 29 : 684 - 684
  • [40] Neoatherosclerosis and Late Stent Thrombosis After Coronary Bare-Metal Stent Implantation: an Optical Coherence Tomography Study
    Kikuta, Yuetsu
    Takebayashi, Hideo
    Hiramatsu, Shigeki
    Goto, Kenji
    Taniguchi, Masahito
    Kodama, Sunao
    Sato, Katsumasa
    Fujiwara, Yasukazu
    Hagikura, Arata
    Haruta, Seiichi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B29 - B30