Usefulness of optical coherence tomography with angiographic coregistration in the guidance of coronary stent implantation

被引:0
|
作者
Takashi Kubo
Yasushi Ino
Yasutsugu Shiono
Kosei Terada
Hiroki Emori
Daisuke Higashioka
Masahiro Takahata
Teruaki Wada
Kunihiro Shimamura
Amir Kh. M. Khalifa
Shengxian Tu
Takashi Akasaka
机构
[1] Wakayama Medical University,Department of Cardiovascular Medicine
[2] Assiut University Hospitals,Department of Cardiovascular Medicine
[3] Shanghai Jiao Tong University,Biomedical Instrument Institute, School of Biomedical Engineering
来源
Heart and Vessels | 2022年 / 37卷
关键词
Optical coherence tomography; Percutaneous coronary intervention; Stent;
D O I
暂无
中图分类号
学科分类号
摘要
Optical coherence tomography (OCT)-angiography coregistration during stent implantation may be useful to avoid geographical mismatch and incomplete lesion coverage. Untreated lipid-rich plaque at stent edge is associated with subsequent stent edge restenosis. The present study sought to compare the frequency of untreated lipid-rich plaque at the stent edge between OCT-guided percutaneous coronary intervention (PCI) with and without OCT-angiography coregistration. We investigated 398 patients who underwent OCT-guided stent implantation (n = 198 in the coregistration group, and n = 200 in the no coregistration group). In OCT after PCI, untreated lipid-lich plaque was identified by the maximum lipid arc > 180˚ in the 5-mm stent edge segment. The PCI-targeted lesion characteristics and stent length were not different between the coregistration group and the no coregistration group. The frequency of untreated lipid-rich plaque in either proximal or distal stent edge segment was significantly lower in the coregistration group than in the no coregistration group (16% vs. 26%, P = 0.015). The frequency of stent-edge dissection (5% vs. 6%, P = 0.516) and untreated stenosis (2% vs. 3%, P = 0.724) was low and without significant differences between the two groups. In OCT-guided PCI, the use of OCT-angiography coregistration was associated with a reduced frequency of untreated lipid-rich plaque at stent edges. OCT-angiography coregistration has a positive impact on PCI results.
引用
收藏
页码:200 / 207
页数:7
相关论文
共 50 条
  • [1] Usefulness of optical coherence tomography with angiographic coregistration in the guidance of coronary stent implantation
    Kubo, Takashi
    Ino, Yasushi
    Shiono, Yasutsugu
    Terada, Kosei
    Emori, Hiroki
    Higashioka, Daisuke
    Takahata, Masahiro
    Wada, Teruaki
    Shimamura, Kunihiro
    Khalifa, Amir Kh. M.
    Tu, Shengxian
    Akasaka, Takashi
    [J]. HEART AND VESSELS, 2022, 37 (02) : 200 - 207
  • [2] Optical coherence tomography to evaluate coronary stent implantation and complications
    Hayat, Umair
    Thondapu, Vikas
    Ul Haq, Muhammad Asrar
    Foin, Nicolas
    Jang, Ik-Kyung
    Barlis, Peter
    [J]. CORONARY ARTERY DISEASE, 2015, 26 : E55 - E68
  • [3] Optical coherence tomography or intravascular ultrasound to optimize coronary stent implantation
    Alfonso, Fernando
    Prati, Francesco
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 (42) : 3148 - 3151
  • [4] Safety and Usefulness of Frequency Domain Optical Coherence Tomography During Coronary Stent Implantation: A Comparison with Intravascular Ultrasound
    Ishigami, Kenichi
    Uemura, Shiro
    Yu, Sugawara
    JiHee, Sung
    Soeda, Tsunenari
    Okayama, Satoshi
    Kawata, Hiroyuki
    Horii, Manabu
    Saito, Yoshihiko
    [J]. CIRCULATION, 2011, 124 (21)
  • [5] Evaluation of aneurysm after coronary stent implantation by optical coherence tomography
    Karabay, Can Yucel
    Kocabay, Gonenc
    Tasar, Onur
    Kalayci, Arzu
    Guler, Ahmet
    Kirma, Cevat
    [J]. KARDIOLOGIA POLSKA, 2013, 71 (06) : 659 - 659
  • [6] The clinical utility of frequency-domain optical coherence tomography guidance for coronary stent implantation compared with intravasucular ultrasound guidance
    Habara, M.
    Nasu, K.
    Terashima, M.
    Ko, Y.
    Ito, T.
    Kurita, T.
    Kinoshita, Y.
    Tsuchikane, E.
    Katoh, O.
    Suzuki, T.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 402 - 402
  • [7] Impact of Frequency-Domain Optical Coherence Tomography Guidance for Optimal Coronary Stent Implantation in Comparison With Intravascular Ultrasound Guidance
    Habara, Maoto
    Nasu, Kenya
    Terashima, Mitsuyasu
    Kaneda, Hideaki
    Yokota, Daisuke
    Ko, Euihong
    Ito, Tsuyoshi
    Kurita, Tairo
    Tanaka, Nobuyoshi
    Kimura, Masashi
    Ito, Tatsuya
    Kinoshita, Yoshihisa
    Tsuchikane, Etsuo
    Asakura, Keiko
    Asakura, Yasushi
    Katoh, Osamu
    Suzuki, Takahiko
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (02) : 193 - 201
  • [8] Effectiveness of Excimer Laser Coronary Angioplasty with Optical Coherence Tomography Guidance for In-stent Restenosis after Drug Eluting Stent Implantation
    Hashimoto, Sho
    Takahashi, Akihiko
    Yamada, Takeshi
    Mizuguchi, Yukio
    Taniguchi, Norimasa
    Nakajima, Shunsuke
    Hata, Tetsuya
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B239 - B239
  • [9] Optical coherence tomography in bioabsorbable stents: mechanism of vascular response and guidance of stent implantation
    Mattesini, A.
    Pighi, M.
    Konstantinidis, N.
    Ghione, M.
    Kilic, D.
    Foin, N.
    Dall'Ara, G.
    Secco, G. G.
    Valente, S.
    Di Mario, C.
    [J]. MINERVA CARDIOANGIOLOGICA, 2014, 62 (01): : 71 - 82
  • [10] The impact on coronary stent implantation at intravascular ultrasound guidance following ''aggressive'' angiographic stent implantation
    Roberts, DK
    Arthur, A
    Bellinger, RL
    Bach, PM
    Fehrenbacher, G
    Berte, LE
    Lindsey, LA
    Hass, SI
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 99223 - 99223