Theoretical and experimental comparison of image signal and noise for dual-energy subtraction angiography and conventional x-ray angiography

被引:3
|
作者
Burton, Christiane S. [1 ,2 ]
Mayo, John R. [3 ,4 ]
Cunningham, Ian A. [1 ,2 ]
机构
[1] Univ Western Ontario, Imaging Res Labs, Robarts Res Inst, London, ON N6A 5B7, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5B7, Canada
[3] Vancouver Gen Hosp, Radiol, Vancouver, BC, Canada
[4] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
关键词
OPTIMIZATION; SYSTEMS;
D O I
10.1117/12.2082724
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Purpose: Cardiovascular disease is currently the leading cause of mortality worldwide. Digital subtraction angiography (DSA) is widely used to enhance the visibility of small vessels and vasculature obscurred by overlying bone and lung fields by subtracting a mask and contrast image. However, motion between these mask and contrast images can introduce artifacts that can render a study non-diagnostic. This makes DSA particularly unsuccessful for cardiac imaging. Energy subtraction angiography (ESA) or dual-energy was proposed in the past as an alternative for vascular imaging, however it was abandonned due to image quality that is inferior to DSA. Image quality for angiography comes down to iodine signal and noise. In this paper we investigate the fundamental iodine signal and noise analysis of ESA and compare it to DSA. Method: We developed a polyenergetic and monoenergetic theoretical model for iodine signal and noise for both ESA and DSA. We validated our polyenergetic model by experiment where ESA and DSA images of a vascular phantom were acquired using an x-ray system with a flat panel CsI Xmaru1215CF-MPTM (Rayence Co., Ltd., Republic of Korea) detector. For ESA low and high applied tube voltages of 50 kV and 120 kV (2.5 mmCu), respectively, and for DSA the applied tube voltage was 80 kV. Iodine signal-to-noise ratio (SNR) per entrance exposure was calculated for each iodine concentration for both ESA and DSA. Results: Our measured iodine SNR agreed well with theoretical calculations. Iodine SNR for ESA was relatively higher than DSA for low iodine mass loadings, and as iodine mass loading increases iodine SNR decreases. Conclusions: We have developed a model for iodine SNR for both DSA and ESA. Our model was validated with experiment and showed excellent agreement. We have shown that there is potential for obtaining iodine-specific images using ESA that are similar to DSA.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Modified Dual-Energy Algorithm for Calcified Plaque Removal Evaluation in Carotid Computed Tomography Angiography and Comparison With Digital Subtraction Angiography
    Mannil, Manoj
    Ramachandran, Jaychandran
    de Martini, Ilaria Vittoria
    Wegener, Susanne
    Schmidt, Bernhard
    Flohr, Thomas
    Krauss, Bernhard
    Valavanis, Antonios
    Alkadhi, Hatem
    Winklhofer, Sebastian
    INVESTIGATIVE RADIOLOGY, 2017, 52 (11) : 680 - 685
  • [22] Comparison of dual-energy X-ray absorptiometry and conventional radiography for the detection of vertebral fractures
    Pavloy, L
    Gamble, GD
    Reid, IR
    JOURNAL OF CLINICAL DENSITOMETRY, 2005, 8 (04) : 379 - 385
  • [23] Realization of one-shot dual-energy X-ray subtraction in general X-ray equipment
    Ying, L
    Xu, LS
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 497 - 498
  • [24] Conventional digital subtraction x-ray angiography versus magnetic resonance angiography in the evaluation of carotid disease: patient satisfaction and preferences
    Hoggard, N
    CLINICAL RADIOLOGY, 2004, 59 (04) : 356 - 357
  • [25] Lung field segmenting in dual-energy subtraction chest x-ray images
    Alvarez, RE
    JOURNAL OF DIGITAL IMAGING, 2004, 17 (01) : 45 - 56
  • [26] Lung Field Segmenting in Dual-Energy Subtraction Chest X-ray Images
    Robert E. Alvarez
    Journal of Digital Imaging, 2004, 17 : 45 - 56
  • [27] LIMITATIONS OF THE LEAD-OXIDE VIDICON FOR DUAL-ENERGY DIGITAL SUBTRACTION ANGIOGRAPHY
    VANLYSEL, MS
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (04) : 530 - 537
  • [28] First results with a novel X-ray source for dual energy angiography
    Baldazzi, G
    Bollini, D
    Celesti, E
    Gambaccini, M
    Gombia, M
    Labanti, C
    Taibi, A
    Tuffanelli, A
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1615 - 1619
  • [29] Automation system of X-ray filter in digital subtraction angiography
    Akaishi, T
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1998, 57 (1-2) : 111 - 114
  • [30] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18