Comparison between two fast threshold strategies: SPARK and SITA in normal subjects

被引:1
|
作者
Say Kiang, Foo [1 ]
Robert Peter, Cubbidge [2 ]
Rebekka, Heitmar [2 ]
机构
[1] SEGi Univ, Fac Optometry & Vis Sci, Petaling Jaya, Malaysia
[2] Aston Univ, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
关键词
Clinical tests; glaucoma; lens; cataract; optics; refraction; instruments; psychophysical testing; retina; techniques of retinal examination; DOUBLING TECHNOLOGY PERIMETRY; NORMAL VISUAL-FIELD; FREQUENCY; EFFICIENT; AGE; ALGORITHMS; VALUES;
D O I
10.1177/1120672120926455
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Numerous fast threshold strategies have been developed in perimetry which use maximum likelihood approaches to estimate the threshold. A recent approach to threshold estimation has been developed estimating the threshold from a limited number of test points which further reduces examination time. This strategy, SPARK, has not been compared to the SITA strategy. The aim of this study was to compare SPARK with SITA in a normal cohort to evaluate within and between strategy agreement in threshold estimates. Methods A total of 83 normal subjects each underwent two visual field examinations with SITA and SPARK on two separate occasions on a randomly selected eye. The eye examined and the order of strategy examined first was randomised but remained constant over the two perimetry visits. Results Visual field examination with SPARK Precision was on average 33% faster than SITA Standard. A positive correlation between group mean sensitivities of SITA Standard and SPARK Precision (rho = 0.713, p < 0.001) was found. In total, 95% of stimulus locations were located within the 95% limits of agreement and linear regression on the differences in sensitivities showed no statistically significant proportional bias (t = 1.713, p = 0.09). Pointwise analysis showed SITA Standard had significantly larger variability for individual stimulus locations examined over two visits when compared to SPARK (t = 9.175, p < 0.001). Conclusion The clinical examination of SPARK yields a sensitivity profile similar to SITA but in a faster examination time. The lower threshold variability of SPARK may be as a result of data smoothing in the threshold estimation process.
引用
收藏
页码:1870 / 1876
页数:7
相关论文
共 50 条
  • [41] Comparison between the alpha pattern in normal subjects and in alpha pattern coma
    McKeown, MJ
    Young, GB
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1997, 14 (05) : 414 - 418
  • [42] Intraocular pressure and pregnancy: A comparison between normal and ocular hypertensive subjects
    Qureshi, IA
    ARCHIVES OF MEDICAL RESEARCH, 1997, 28 (03): : 397 - 400
  • [43] Comparison Of Upper Airway Anatomic Structures Between Obese Normal Subjects And Obese Apneic Subjects
    Chi, L.
    Kim, C.
    Jackson, N.
    Maislin, G.
    Schwab, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183
  • [44] COMPARISON BETWEEN IMIPRAMINE AND DESIPRAMINE IN NORMAL SUBJECTS AND THEIR ACTION IN DEPRESSIVE PATIENTS
    POLDINGER, W
    PSYCHOPHARMACOLOGIA, 1963, 4 (04): : 302 - 307
  • [45] Effects of two different types of fast food on postprandial metabolism in normal and overweight subjects
    A Ramel
    F D Gudmundsdottir
    I Thorsdottir
    European Journal of Clinical Nutrition, 2012, 66 : 1193 - 1198
  • [46] Performance comparison of two fast resource management strategies for ATM networks
    Cheng, TH
    Subramanian, KR
    Mudakanavar, PN
    ELECTRONICS LETTERS, 1998, 34 (06) : 525 - 526
  • [47] Effects of two different types of fast food on postprandial metabolism in normal and overweight subjects
    Ramel, A.
    Gudmundsdottir, F. D.
    Thorsdottir, I.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2012, 66 (11) : 1193 - 1198
  • [48] Comparison between two cord blood collection strategies
    Solves, P
    Mirabet, V
    Larrea, L
    Moraga, R
    Planelles, D
    Saucedo, E
    Uberos, FC
    Planells, T
    Guillen, M
    Andres, A
    Monleon, J
    Soler, MA
    Franco, E
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2003, 82 (05) : 439 - 442
  • [49] Comparison between two quantiles: The normal and exponential cases
    Guo, HZ
    Krishnamoorthy, K
    COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 2005, 34 (02) : 243 - 252
  • [50] MUAP values of two facial muscles in normal subjects and comparison of two methods for data analysis
    Papagianni, Aikaterini E.
    Kokotis, Panagiotis
    Zambelis, Thomas
    Karandreas, Nikos
    MUSCLE & NERVE, 2012, 46 (03) : 346 - 350