Comparison between two fast threshold strategies: SPARK and SITA in normal subjects

被引:1
|
作者
Say Kiang, Foo [1 ]
Robert Peter, Cubbidge [2 ]
Rebekka, Heitmar [2 ]
机构
[1] SEGi Univ, Fac Optometry & Vis Sci, Petaling Jaya, Malaysia
[2] Aston Univ, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
关键词
Clinical tests; glaucoma; lens; cataract; optics; refraction; instruments; psychophysical testing; retina; techniques of retinal examination; DOUBLING TECHNOLOGY PERIMETRY; NORMAL VISUAL-FIELD; FREQUENCY; EFFICIENT; AGE; ALGORITHMS; VALUES;
D O I
10.1177/1120672120926455
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Numerous fast threshold strategies have been developed in perimetry which use maximum likelihood approaches to estimate the threshold. A recent approach to threshold estimation has been developed estimating the threshold from a limited number of test points which further reduces examination time. This strategy, SPARK, has not been compared to the SITA strategy. The aim of this study was to compare SPARK with SITA in a normal cohort to evaluate within and between strategy agreement in threshold estimates. Methods A total of 83 normal subjects each underwent two visual field examinations with SITA and SPARK on two separate occasions on a randomly selected eye. The eye examined and the order of strategy examined first was randomised but remained constant over the two perimetry visits. Results Visual field examination with SPARK Precision was on average 33% faster than SITA Standard. A positive correlation between group mean sensitivities of SITA Standard and SPARK Precision (rho = 0.713, p < 0.001) was found. In total, 95% of stimulus locations were located within the 95% limits of agreement and linear regression on the differences in sensitivities showed no statistically significant proportional bias (t = 1.713, p = 0.09). Pointwise analysis showed SITA Standard had significantly larger variability for individual stimulus locations examined over two visits when compared to SPARK (t = 9.175, p < 0.001). Conclusion The clinical examination of SPARK yields a sensitivity profile similar to SITA but in a faster examination time. The lower threshold variability of SPARK may be as a result of data smoothing in the threshold estimation process.
引用
收藏
页码:1870 / 1876
页数:7
相关论文
共 50 条
  • [31] Sonography of the Normal Lung: Comparison Between Young and Elderly Subjects
    Chiesa, Anna Maria
    Ciccarese, Federica
    Gardelli, Greta
    Regina, Ugo Maria
    Feletti, Francesco
    Bacchi Reggiani, Maria Letizia
    Zompatori, Maurizio
    JOURNAL OF CLINICAL ULTRASOUND, 2015, 43 (04) : 230 - 234
  • [32] A comparison between two empirical downscaling strategies
    Benestad, RE
    INTERNATIONAL JOURNAL OF CLIMATOLOGY, 2001, 21 (13) : 1645 - 1668
  • [33] COMPARISON OF COPING STRATEGIES AND EMOTIONAL INTELLIGENCE IN BORDERLINE PERSONALITY DISORDER AND NORMAL SUBJECTS
    Jamilian, H.
    EUROPEAN PSYCHIATRY, 2009, 24
  • [34] Association between task performance and tender point pain threshold to pressure in normal subjects
    Farrell, J
    Littlejohn, GO
    JOURNAL OF MUSCULOSKELETAL PAIN, 1997, 5 (01): : 19 - 47
  • [35] EVALUATION OF TWO HUMPHREY PERIMETRY PROGRAMS;FULL THRESH- OLD AND SITA -STANDARD TESTING STRATEGY FOR LEARNING EFFECT IN NORMAL SUBJECTS
    O.Yenice
    A.Temel
    F.Orucov
    国际眼科杂志, 2003, (01) : 61 - 62
  • [36] METABOLIC DIFFERENCES BETWEEN MALES AND FEMALES AND BETWEEN NORMAL AND OBESE SUBJECTS DURING TOTAL FAST
    GOSCHKE, H
    GIRARD, J
    STAHL, M
    KLINISCHE WOCHENSCHRIFT, 1976, 54 (11): : 527 - 533
  • [37] BIOSYNTHESIS OF CHOLESTEROL IN HUMAN SKIN - COMPARISON BETWEEN NORMAL AND HYPERLIPOPROTEINEMIC SUBJECTS
    MENDELSO.D
    MENDELSO.L
    SOUTH AFRICAN MEDICAL JOURNAL, 1972, 46 (09): : 229 - &
  • [38] Comparison of electrocardiographic repolarization patterns between hypogonad males and normal subjects
    Kirilmaz, A
    Bolu, E
    Kilicaslan, F
    Erinc, K
    Uzun, M
    Isik, E
    Ozata, M
    Ozdemir, C
    Demirtas, E
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2003, 8 (04) : 284 - 288
  • [39] INTERHEMISPHERIC TRANSFER OF MOVEMENT AFTEREFFECTS - COMPARISON BETWEEN ACALLOSAL AND NORMAL SUBJECTS
    DIXON, NF
    JEEVES, MA
    PSYCHONOMIC SCIENCE, 1970, 20 (04): : 201 - 203
  • [40] Comparison of plasma endothelin levels between osteoporotic, osteopenic and normal subjects
    Hasan Hilmi Muratli
    Levent Çelebi
    Onur Hapa
    Ali Biçimoğlu
    BMC Musculoskeletal Disorders, 6