Comparison between two fast threshold strategies: SPARK and SITA in normal subjects

被引:1
|
作者
Say Kiang, Foo [1 ]
Robert Peter, Cubbidge [2 ]
Rebekka, Heitmar [2 ]
机构
[1] SEGi Univ, Fac Optometry & Vis Sci, Petaling Jaya, Malaysia
[2] Aston Univ, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
关键词
Clinical tests; glaucoma; lens; cataract; optics; refraction; instruments; psychophysical testing; retina; techniques of retinal examination; DOUBLING TECHNOLOGY PERIMETRY; NORMAL VISUAL-FIELD; FREQUENCY; EFFICIENT; AGE; ALGORITHMS; VALUES;
D O I
10.1177/1120672120926455
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Numerous fast threshold strategies have been developed in perimetry which use maximum likelihood approaches to estimate the threshold. A recent approach to threshold estimation has been developed estimating the threshold from a limited number of test points which further reduces examination time. This strategy, SPARK, has not been compared to the SITA strategy. The aim of this study was to compare SPARK with SITA in a normal cohort to evaluate within and between strategy agreement in threshold estimates. Methods A total of 83 normal subjects each underwent two visual field examinations with SITA and SPARK on two separate occasions on a randomly selected eye. The eye examined and the order of strategy examined first was randomised but remained constant over the two perimetry visits. Results Visual field examination with SPARK Precision was on average 33% faster than SITA Standard. A positive correlation between group mean sensitivities of SITA Standard and SPARK Precision (rho = 0.713, p < 0.001) was found. In total, 95% of stimulus locations were located within the 95% limits of agreement and linear regression on the differences in sensitivities showed no statistically significant proportional bias (t = 1.713, p = 0.09). Pointwise analysis showed SITA Standard had significantly larger variability for individual stimulus locations examined over two visits when compared to SPARK (t = 9.175, p < 0.001). Conclusion The clinical examination of SPARK yields a sensitivity profile similar to SITA but in a faster examination time. The lower threshold variability of SPARK may be as a result of data smoothing in the threshold estimation process.
引用
收藏
页码:1870 / 1876
页数:7
相关论文
共 50 条
  • [21] Comparison of ZETA Fast (PTS) (Optopol Technology) and Humphrey SITA Fast (SFA) (Carl Zeiss Meditec) Perimetric Strategies
    Mathews, Basil
    Laux, Jeff
    Barnhart, Cassandra
    Fleischman, David
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [22] A Comparison of False-negative Responses for Full Threshold and SITA Standard Perimetry in Glaucoma Patients and Normal Observers
    Johnson, Chris A.
    Sherman, Kathryn
    Doyle, Carrie
    Wall, Michael
    JOURNAL OF GLAUCOMA, 2014, 23 (05) : 288 - 292
  • [24] SITA standard versus full threshold strategies:: A comparison for global indices and examination time in a large sample of visual fields
    Goni, FJ
    Guarro, M
    Borrás, R
    Ondategui, JC
    Peris, EJ
    Sanchez-Olaso, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U493 - U493
  • [25] Normal values of exhaled carbon monoxide in healthy subjects: comparison between two methods of assessment
    Moscato, Umberto
    Poscia, Andrea
    Gargaruti, Riccardo
    Capelli, Giovanni
    Cavaliere, Franco
    BMC PULMONARY MEDICINE, 2014, 14
  • [26] Normal values of exhaled carbon monoxide in healthy subjects: comparison between two methods of assessment
    Umberto Moscato
    Andrea Poscia
    Riccardo Gargaruti
    Giovanni Capelli
    Franco Cavaliere
    BMC Pulmonary Medicine, 14
  • [27] A COMPARISON OF THE RANGE OF WALKING SPEEDS BETWEEN NORMAL AND HEMIPLEGIC SUBJECTS
    TURNBULL, GI
    CHARTERIS, J
    WALL, JC
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1995, 27 (03): : 175 - 182
  • [28] Comparison of optic disc topography between migrainous and normal subjects
    Elgin, Ufuk
    Cankaya, Buelent
    Batman, Aygen
    Acaroglu, Golge
    Orhan, Gurdal
    NEURO-OPHTHALMOLOGY, 2007, 31 (03) : 59 - 62
  • [29] Comparison of Glucose and Insulin Profile Between Normal and Prediabetic Subjects
    Kumar, Ava S.
    Babiarz, Joseph W.
    METABOLISM-CLINICAL AND EXPERIMENTAL, 2024, 153
  • [30] A COMPARISON OF EMG ACTIVITY BETWEEN NORMAL SUBJECTS AND PATIENTS WITH TMD
    WILDING, RJC
    SHAIKH, M
    PATEL, N
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 1011 - 1011