Comparison between two fast threshold strategies: SPARK and SITA in normal subjects

被引:1
|
作者
Say Kiang, Foo [1 ]
Robert Peter, Cubbidge [2 ]
Rebekka, Heitmar [2 ]
机构
[1] SEGi Univ, Fac Optometry & Vis Sci, Petaling Jaya, Malaysia
[2] Aston Univ, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
关键词
Clinical tests; glaucoma; lens; cataract; optics; refraction; instruments; psychophysical testing; retina; techniques of retinal examination; DOUBLING TECHNOLOGY PERIMETRY; NORMAL VISUAL-FIELD; FREQUENCY; EFFICIENT; AGE; ALGORITHMS; VALUES;
D O I
10.1177/1120672120926455
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Numerous fast threshold strategies have been developed in perimetry which use maximum likelihood approaches to estimate the threshold. A recent approach to threshold estimation has been developed estimating the threshold from a limited number of test points which further reduces examination time. This strategy, SPARK, has not been compared to the SITA strategy. The aim of this study was to compare SPARK with SITA in a normal cohort to evaluate within and between strategy agreement in threshold estimates. Methods A total of 83 normal subjects each underwent two visual field examinations with SITA and SPARK on two separate occasions on a randomly selected eye. The eye examined and the order of strategy examined first was randomised but remained constant over the two perimetry visits. Results Visual field examination with SPARK Precision was on average 33% faster than SITA Standard. A positive correlation between group mean sensitivities of SITA Standard and SPARK Precision (rho = 0.713, p < 0.001) was found. In total, 95% of stimulus locations were located within the 95% limits of agreement and linear regression on the differences in sensitivities showed no statistically significant proportional bias (t = 1.713, p = 0.09). Pointwise analysis showed SITA Standard had significantly larger variability for individual stimulus locations examined over two visits when compared to SPARK (t = 9.175, p < 0.001). Conclusion The clinical examination of SPARK yields a sensitivity profile similar to SITA but in a faster examination time. The lower threshold variability of SPARK may be as a result of data smoothing in the threshold estimation process.
引用
收藏
页码:1870 / 1876
页数:7
相关论文
共 50 条
  • [1] Threshold fluctuation comparison between Oculus Smartfield Spark strategy and Humphrey Sita Fast
    Abreu, Rodrigo
    Rodriguez-Esteve, Paloma
    Pena-Betancor, Cristina
    Gonzalez-Hernandez, Marta
    Gonzalez-de la Rosa, Manuel
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [2] Comparison of Advanced Threshold and SITA Fast Perimetric Strategies
    Sikorski, Bartosz L.
    Laudencka, Adriana
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [3] Properties of perimetric threshold estimates from full threshold, SITA standard, and SITA fast strategies
    Artes, PH
    Iwase, A
    Ohno, Y
    Kitazawa, Y
    Chauban, BC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (08) : 2654 - 2659
  • [4] Inter-subject variability and normal limits of the SITA standard, SITA fast, and the Humphrey full threshold computerized perimetry strategies, SITA STATPAC
    Bengtsson, B
    Heijl, A
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1999, 77 (02): : 125 - 129
  • [5] Comparison of selected parameters of sita fast and full threshold strategies in evaluation of glaucoma suspects
    Nowomiejska, K
    Kawa, P
    Zarnowski, T
    Bialek, M
    Zagorski, Z
    PERIMETRY UPDATE 2002/2003, 2004, : 129 - 133
  • [6] Short- and long-term fluctuation in normal subjects for the SITA-Standard and SITA-Fast threshold algorithms.
    Killoran, JA
    Hutchings, N
    Archibald, SK
    Prokopich, CL
    Flanagan, JG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S284 - S284
  • [7] Comparison of two fast strategies, SITA Fast and TOP, for the assessment of visual fields in glaucoma patients
    King, AJW
    Taguri, A
    Wadood, AC
    Azuara-Blanco, A
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2002, 240 (06) : 481 - 487
  • [8] Comparison of two fast strategies, SITA Fast and TOP, for the assessment of visual fields in glaucoma patients
    A. King
    A. Taguri
    A. Wadood
    A. Azuara-Blanco
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2002, 240 : 481 - 487
  • [9] Evaluation of a new threshold visual field strategy, SITA, in normal subjects
    Bengtsson, B
    Heijl, A
    Olsson, J
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 (02): : 165 - 169
  • [10] Comparison of Virtual Field Device to Humphrey Visual Field SITA-Fast in Normal Subjects
    Tubene, Lydie
    McLaughlin, Mallory
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)