Measurement of trabecular bone parameters with different bone thicknesses and voxel sizes in mice using micro-CT

被引:1
|
作者
Abu Bakar, Nurin Nadzlah [1 ]
Saidi, Basri [1 ]
Yamin, Lyana Shahirah Mohamad [1 ]
机构
[1] Univ Teknol MARA Puncak Alam, Fac Hlth Sci, Bandar Puncak Alam 42300, Selangor, Malaysia
关键词
Micro-CT; trabecular bone parameter; bone thickness; voxel size; mice; TOMOGRAPHY;
D O I
10.11113/mjfas.v15n2019.1128
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Micro-CT is one of the best modalities in assessing bone morphology and microarchitecture in small animal models. Voxel size is directly related to the image resolution as it influences the bone morphology results. The purpose of this study was to assess the effects of double dagger different thicknesses of structures on the trabecular bone qualitative parameters. It was also to find out the most appropriate voxel size when scanning a certain or specific body part with different thicknesses. Five BALB-C breed mice carcasses were scanned using two different voxel sizes of 18 and 35 mu m. The scanning acquisition times were recorded to be compared and the trabecular bone parameters measurements were taken. Both trabecular number and trabecular separation were increased in thicker structures meanwhile bone volume fraction and trabecular thickness values were inconsistent with the increment of the structure thickness. The bone volume fraction, trabecular thickness and trabecular separation were higher in larger voxel size and vice versa for trabecular number. The scanning acquisition time has no apparent correlation with the trabecular bone parameters. The thickness of the bone structure did affect trabecular number and trabecular separation significantly but less affecting bone volume fraction and trabecular thickness. All trabecular bone parameters were found affected by the size of scanning voxel size used. The usage of 35 mu m voxel was more recommended than 18 mu m to save time and give out less radiation dose to specimen unless the detailed features of the trabecular pattern was very important.
引用
收藏
页码:65 / 68
页数:4
相关论文
共 50 条
  • [1] Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study
    Tayman, Mahmure Ayse
    Kamburoglu, Kivanc
    Ocak, Mert
    Ozen, Dogukan
    [J]. IMAGING SCIENCE IN DENTISTRY, 2022, 52 (02) : 171 - 179
  • [2] 3D analysis of the trabecular bone using micro-CT
    Moon, HS
    Shim, WH
    Lim, BJ
    Kim, KD
    Kim, HJ
    Chung, MK
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 : B323 - B323
  • [3] Influence of segmentation on micro-CT images of trabecular bone
    Tassani, S.
    Korfiatis, V.
    Matsopoulos, G. K.
    [J]. JOURNAL OF MICROSCOPY, 2014, 256 (02) : 75 - 81
  • [4] Automatic thresholding of micro-CT trabecular bone images
    Zhang, Yongping
    He, Zhongkun
    Fan, Shaojing
    He, Kejia
    Li, Chen
    [J]. BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 23 - +
  • [5] The assessment of trabecular bone parameters and cortical bone strength: A comparison of micro-CT and dental cone-beam CT
    Hsu, Jui-Ting
    Wang, Shun-Ping
    Huang, Heng-Li
    Chen, Ying-Ju
    Wu, Jay
    Tsai, Ming-Tzu
    [J]. JOURNAL OF BIOMECHANICS, 2013, 46 (15) : 2611 - 2618
  • [6] A Comparison of Micro-CT and Dental CT in Assessing Cortical Bone Morphology and Trabecular Bone Microarchitecture
    Hsu, Jui-Ting
    Chen, Ying-Ju
    Ho, Jung-Ting
    Huang, Heng-Li
    Wang, Shun-Ping
    Cheng, Fu-Chou
    Wu, Jay
    Tsai, Ming-Tzu
    [J]. PLOS ONE, 2014, 9 (09):
  • [7] Reproducibility and agreement of micro-CT and histomorphometry in human trabecular bone with different metabolic status
    Tamminen, Inari S.
    Isaksson, Hanna
    Aula, Antti S.
    Honkanen, Eero
    Jurvelin, Jukka S.
    Kroger, Heikki
    [J]. JOURNAL OF BONE AND MINERAL METABOLISM, 2011, 29 (04) : 442 - 448
  • [8] Micro-CT characterization of human trabecular bone in osteogenesis imperfecta
    Jameson, John
    Albert, Carolyne
    Smith, Peter
    Molthen, Robert
    Harris, Gerald
    [J]. MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [9] Reproducibility and agreement of micro-CT and histomorphometry in human trabecular bone with different metabolic status
    Inari S. Tamminen
    Hanna Isaksson
    Antti S. Aula
    Eero Honkanen
    Jukka S. Jurvelin
    Heikki Kröger
    [J]. Journal of Bone and Mineral Metabolism, 2011, 29 : 442 - 448
  • [10] Preparation of on-axis cylindrical trabecular bone specimens using micro-CT imaging
    Wang, X
    Liu, XY
    Niebur, GL
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (01): : 122 - 125