Micro-CT characterization of human trabecular bone in osteogenesis imperfecta

被引:1
|
作者
Jameson, John [1 ,2 ]
Albert, Carolyne [1 ,2 ]
Smith, Peter [2 ,3 ]
Molthen, Robert [1 ,2 ,4 ,5 ]
Harris, Gerald [1 ,2 ,3 ]
机构
[1] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53233 USA
[2] Orthopaed & Rehabilitat Engn Ctr, Milwaukee, WI USA
[3] Shriners Hosp Children, Chicago, IL USA
[4] Med Coll Wisconsin, Dept Med, Milwaukee, WI USA
[5] Zablocki VA Med Ctr, Dept Vet Affairs, Milwaukee, WI USA
关键词
Osteogenesis imperfecta; mu CT; bone histomorphometry; trabecular bone; trabecular structure; bone mineral density; connectivity; CHILDREN; HISTOMORPHOMETRY;
D O I
10.1117/12.877586
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Osteogenesis imperfecta (OI) is a genetic syndrome affecting collagen synthesis and assembly. Its symptoms vary widely but commonly include bone fragility, reduced stature, and bone deformity. Because of the small size and paucity of human specimens, there is a lack of biomechanical data for OI bone. Most literature has focused on histomorphometric analyses, which rely on assumptions to extrapolate 3-D properties. In this study, a micro-computed tomography (mu CT) system was used to directly measure structural and mineral properties in pediatric OI bone collected during routine surgical procedures. Surface renderings suggested a poorly organized, plate-like orientation. Patients with a history of bone-augmenting drugs exhibited increased bone volume fraction (BV/TV), trabecular number (Tb.N), and connectivity density (Eu.Conn.D). The latter two parameters appeared to be related to OI severity. Structural results were consistently higher than those reported in a previous histomorphometric study, but these differences can be attributed to factors such as specimen collection site, drug therapy, and assumptions associated with histomorphometry. Mineral testing revealed strong correlations with several structural parameters, highlighting the importance of a dual approach in trabecular bone testing. This study reports some of the first quantitative mu CT data of human OI bone, and it suggests compelling possibilities for the future of OI bone assessment.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Classification of micro-CT images using 3D characterization of bone canal patters in human osteogenesis imperfecta
    Abidin, Anas Z.
    Jameson, John
    Molthen, Robert
    Wismueller, Axel
    [J]. MEDICAL IMAGING 2017: COMPUTER-AIDED DIAGNOSIS, 2017, 10134
  • [2] Characterization of Human Cortical and Trabecular Bone Structural Change by NMR and Micro-CT
    Ni, Qingwen
    Bredbenner, Todd
    [J]. PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 545 - 546
  • [3] Automatic thresholding of micro-CT trabecular bone images
    Zhang, Yongping
    He, Zhongkun
    Fan, Shaojing
    He, Kejia
    Li, Chen
    [J]. BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 23 - +
  • [4] Influence of segmentation on micro-CT images of trabecular bone
    Tassani, S.
    Korfiatis, V.
    Matsopoulos, G. K.
    [J]. JOURNAL OF MICROSCOPY, 2014, 256 (02) : 75 - 81
  • [5] TRABECULAR BONE SCORE IN OSTEOGENESIS IMPERFECTA: IS IT USEFUL?
    Florez, H.
    Muxi, A.
    Gonzalez-Roca, E.
    Monegal, A.
    Guanabens, N.
    Peris, P.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2020, 31 (SUPPL 1) : S146 - S146
  • [6] A comparative evaluation of cone beam CT and micro-CT on trabecular bone structures in the human mandible
    Van Dessel, J.
    Huang, Y.
    Depypere, M.
    Rubira-Bullen, I.
    Maes, F.
    Jacobs, R.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (08)
  • [7] Characterization of Rotating Gantry Micro-CT Configuration for the In Vivo Evaluation of Murine Trabecular Bone
    Arentsen, Luke
    Hui, Susanta
    [J]. MICROSCOPY AND MICROANALYSIS, 2013, 19 (04) : 907 - 913
  • [8] Stereolithographic models simulating trabecular bone and their characterization by thin-slice- and micro-CT
    K. Engelke
    C. Süß
    W. Kalender
    [J]. European Radiology, 2001, 11 : 2026 - 2040
  • [9] Reproducibility and agreement of micro-CT and histomorphometry in human trabecular bone with different metabolic status
    Tamminen, Inari S.
    Isaksson, Hanna
    Aula, Antti S.
    Honkanen, Eero
    Jurvelin, Jukka S.
    Kroger, Heikki
    [J]. JOURNAL OF BONE AND MINERAL METABOLISM, 2011, 29 (04) : 442 - 448
  • [10] Reproducibility and agreement of micro-CT and histomorphometry in human trabecular bone with different metabolic status
    Inari S. Tamminen
    Hanna Isaksson
    Antti S. Aula
    Eero Honkanen
    Jukka S. Jurvelin
    Heikki Kröger
    [J]. Journal of Bone and Mineral Metabolism, 2011, 29 : 442 - 448