Reproducibility and agreement of micro-CT and histomorphometry in human trabecular bone with different metabolic status

被引:0
|
作者
Inari S. Tamminen
Hanna Isaksson
Antti S. Aula
Eero Honkanen
Jukka S. Jurvelin
Heikki Kröger
机构
[1] University of Eastern Finland,Department of Physics and Mathematics
[2] University of Eastern Finland,Bone and Cartilage Research Unit (BCRU)
[3] Kuopio University Hospital,Department of Orthopaedics and Traumatology
[4] Helsinki University Central Hospital,Division of Nephrology, Department of Medicine
来源
关键词
Trabecular bone; Iliac crest; Osteoporosis; Renal osteodystrophy;
D O I
暂无
中图分类号
学科分类号
摘要
The use of micro-computed tomography (micro-CT) to study bone microstructure is continuously increasing. Thus, it is important to ensure that micro-CT can differentiate healthy and pathological bone. This study aimed to determine whether the reproducibility of bone histomorphometry and micro-CT, and agreement between the techniques, vary in bone samples with different metabolic status. Iliac crest biopsies (n = 36) were obtained from healthy subjects (n = 10) and from patients with osteoporosis (OP) (n = 15) or renal osteodystrophy (ROD) (n = 11). Micro-CT and histomorphometry analyses were repeated twice. Results were analyzed in separate groups and after pooling the data. Bone histomorphometry detected generally known differences between the diseases, whereas micro-CT did not detect differences between normal and ROD samples as effectively. Repeated measurements for BV/TV, Tb.Th, Tb.N, and Tb.Sp exhibited linear correlation coefficients (ρ) of 0.87–0.92 [coefficients of variations (CV), 8.3–27.2%] for histomorphometry and of 0.66–0.94 (CV, 4.4–23.4%) for micro-CT. There were no significant differences in reproducibility among samples from different study groups. Correlations between BV/TV (micro-CT) and mineralized bone volume (Md.V/TV, histomorphometry) were weaker than between BV/TV (micro-CT) and BV/TV (histomorphometry). When comparing the techniques, BV/TV, Tb.Th, and Tb.N displayed moderate correlations (ρ = 0.39–0.62, P < 0.05), and the agreement for BV/TV was highest in OP samples. The agreement between the techniques using clinical bone samples was moderate. Especially, micro-CT was less effective than bone histomorphometry in differentiating ROD from normal samples. The reproducibility was not affected by the health status of bone. Histomorphometry is still needed in clinical practice to study the remodeling balance in bone, and the methods are complementary.
引用
收藏
页码:442 / 448
页数:6
相关论文
共 50 条
  • [1] Reproducibility and agreement of micro-CT and histomorphometry in human trabecular bone with different metabolic status
    Tamminen, Inari S.
    Isaksson, Hanna
    Aula, Antti S.
    Honkanen, Eero
    Jurvelin, Jukka S.
    Kroger, Heikki
    JOURNAL OF BONE AND MINERAL METABOLISM, 2011, 29 (04) : 442 - 448
  • [2] Metabolic status of human trabecular bone affects reproducibility and agreement of microCT and histomorphometry
    Tamminen, I.
    Aula, A.
    Isaksson, H.
    Jurvelin, J. S.
    Kroger, H.
    BONE, 2009, 44 (02) : S379 - S380
  • [3] Micro-CT characterization of human trabecular bone in osteogenesis imperfecta
    Jameson, John
    Albert, Carolyne
    Smith, Peter
    Molthen, Robert
    Harris, Gerald
    MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [4] A comparison of micro-CT, microradiography and histomorphometry in bone research
    Gielkens, Pepijn F. M.
    Schortinghuis, Jurjen
    de Jong, Johan R.
    Huysmans, Marie Charlotte D. N. J. M.
    van Leeuwen, M. Barbara M.
    Raghoebar, Gerry M.
    Bos, Ruud R. M.
    Stegenga, Boudewijn
    ARCHIVES OF ORAL BIOLOGY, 2008, 53 (06) : 558 - 566
  • [5] Micro-CT in the Assessment of Pediatric Renal osteodystrophy by Bone Histomorphometry
    Pereira, Renata C.
    Bischoftt, David S.
    Yamaguchi, Dean
    Salusky, Isidro B.
    Wesseling-Perry, Katherine
    CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2016, 11 (03): : 481 - 487
  • [6] Automatic thresholding of micro-CT trabecular bone images
    Zhang, Yongping
    He, Zhongkun
    Fan, Shaojing
    He, Kejia
    Li, Chen
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 23 - +
  • [7] Influence of segmentation on micro-CT images of trabecular bone
    Tassani, S.
    Korfiatis, V.
    Matsopoulos, G. K.
    JOURNAL OF MICROSCOPY, 2014, 256 (02) : 75 - 81
  • [8] Characterization of Human Cortical and Trabecular Bone Structural Change by NMR and Micro-CT
    Ni, Qingwen
    Bredbenner, Todd
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 545 - 546
  • [9] A comparative evaluation of cone beam CT and micro-CT on trabecular bone structures in the human mandible
    Van Dessel, J.
    Huang, Y.
    Depypere, M.
    Rubira-Bullen, I.
    Maes, F.
    Jacobs, R.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (08)
  • [10] Measurement of trabecular bone parameters with different bone thicknesses and voxel sizes in mice using micro-CT
    Abu Bakar, Nurin Nadzlah
    Saidi, Basri
    Yamin, Lyana Shahirah Mohamad
    MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2019, 15 (01): : 65 - 68