The assessment of trabecular bone parameters and cortical bone strength: A comparison of micro-CT and dental cone-beam CT

被引:37
|
作者
Hsu, Jui-Ting [1 ]
Wang, Shun-Ping [2 ]
Huang, Heng-Li [1 ]
Chen, Ying-Ju [3 ]
Wu, Jay [4 ]
Tsai, Ming-Tzu [5 ]
机构
[1] China Med Univ, Coll Med, Sch Dent, Taichung 404, Taiwan
[2] Taichung Vet Gen Hosp, Dept Orthopaed, Taichung 407, Taiwan
[3] Taichung Vet Gen Hosp, Stem Cell Med Res Ctr, Dept Med Res, Taichung 407, Taiwan
[4] China Med Univ, Dept Biomed Imaging & Radiol Sci, Taichung 404, Taiwan
[5] Hungkuang Univ, Dept Biomed Engn, Taichung 433, Taiwan
关键词
Dental cone-beam computed tomography (dental CBCT); Micro-computed tomography (micro-CT); Bone mineral density (BMD); Trabecular bone structural parameter; Three-point bending; Cortical bone strength; Rat femur; COMPUTED-TOMOGRAPHY; RAT FEMUR; PQCT; DENSITY; INDEX; VALIDATION; GUIDELINES; VALUES;
D O I
10.1016/j.jbiomech.2013.08.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study compared the capabilities of micro-computed tomography (micro-CT) and dental cone-beam computed tomography (CBCT) in assessing trabecular bone parameters and cortical bone strength. Micro-CT and CBCT scans were applied to 28 femurs from 14 rats to obtain independent measurements of the volumetric cancellous bone mineral density (vCanBMD) in the femoral head, volumetric cortical bone mineral density (vCtBMD) in the femoral diaphysis, cross-sectional moment of inertia (CSMI), and bone strength index (BSI) (=CSMI x vCtBMD). Five structural parameters of the trabecular bone of the femoral head were calculated from micro-CT images. A three-point bending test was then conducted to measure the fracture load of each femur. Bivariate linear Pearson analysis was conducted to calculate the correlation coefficients (r values) of the micro-CT, dental CBCT, and three-point bending measurements. The statistical analyses showed a strong correlation between vCanBMD values obtained using micro-CT and dental CBCT (r=0.830). There were strong or moderate correlation between vCanBMD measured using dental CBCT and five parameters of trabecular structure measured using micro-CT. Additionally, the results were satisfactory regardless of whether micro-CT or dental CBCT was used to measure the femoral diaphysis vCtBMD (r=0.733 and 0.680, respectively), CSMI (r=0.756 and 0.726, respectively), or BSI (r=0.846 and 0.847, respectively) to predict fracture loads. This study has yielded a new method for using dental CBCT to evaluate bone parameters and bone strength; however, further studies are necessary to validate the use of dental CBCT on humans. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2611 / 2618
页数:8
相关论文
共 50 条
  • [1] A Comparison of Micro-CT and Dental CT in Assessing Cortical Bone Morphology and Trabecular Bone Microarchitecture
    Hsu, Jui-Ting
    Chen, Ying-Ju
    Ho, Jung-Ting
    Huang, Heng-Li
    Wang, Shun-Ping
    Cheng, Fu-Chou
    Wu, Jay
    Tsai, Ming-Tzu
    PLOS ONE, 2014, 9 (09):
  • [2] Predicting Cortical Bone Strength from DXA and Dental Cone-Beam CT
    Hsu, Jui-Ting
    Chen, Ying-Ju
    Tsai, Ming-Tzu
    Lan, Howard Haw-Chang
    Cheng, Fu-Chou
    Chen, Michael Y. C.
    Wang, Shun-Ping
    PLOS ONE, 2012, 7 (11):
  • [3] A comparative evaluation of cone beam CT and micro-CT on trabecular bone structures in the human mandible
    Van Dessel, J.
    Huang, Y.
    Depypere, M.
    Rubira-Bullen, I.
    Maes, F.
    Jacobs, R.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (08)
  • [4] Comparison of anterior and posterior trabecular bone microstructure of human mandible using cone-beam CT and micro CT
    Ibrahim, Norliza
    Parsa, Azin
    Hassan, Bassam
    van der Stelt, Paul
    Rahmat, Rabiah A.
    Ismail, Siti M.
    Aartman, Irene H. A.
    BMC ORAL HEALTH, 2021, 21 (01)
  • [5] Comparison of anterior and posterior trabecular bone microstructure of human mandible using cone-beam CT and micro CT
    Norliza Ibrahim
    Azin Parsa
    Bassam Hassan
    Paul van der Stelt
    Rabiah A. Rahmat
    Siti M. Ismail
    Irene H. A. Aartman
    BMC Oral Health, 21
  • [6] Cone-beam reconstruction for micro-CT
    Wang, G
    Jiang, M
    Lee, SW
    Liu, H
    Hoffman, E
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 384 - 387
  • [7] Multislice-CT for structure - Analysis of trabecular bone - a comparison with Micro-CT and biomechanical strength
    Bauer, JS
    Issever, AS
    Fischbeck, M
    Burghardt, A
    Eckstein, F
    Rummeny, EJ
    Majumdar, S
    Link, TM
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (05): : 709 - 718
  • [8] Geometric Parameters Estimation and Calibration in Cone-Beam Micro-CT
    Zhao, Jintao
    Hu, Xiaodong
    Zou, Jing
    Hu, Xiaotang
    SENSORS, 2015, 15 (09) : 22811 - 22825
  • [9] Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT
    Parsa, Azin
    Ibrahim, Norliza
    Hassan, Bassam
    van der Stelt, Paul
    Wismeijer, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (01) : E1 - E7
  • [10] Comparison of micro-CT and cone beam CT on the feasibility of assessing trabecular structures in mandibular condyle
    Liang, Xin
    Zhang, Zuyan
    Gu, Jianping
    Wang, Zhihui
    Vandenberghe, Bart
    Jacobs, Reinhilde
    Yang, Jie
    Ma, Guowu
    Ling, Haibin
    Ma, Xuchen
    DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (05)