The assessment of trabecular bone parameters and cortical bone strength: A comparison of micro-CT and dental cone-beam CT

被引:37
|
作者
Hsu, Jui-Ting [1 ]
Wang, Shun-Ping [2 ]
Huang, Heng-Li [1 ]
Chen, Ying-Ju [3 ]
Wu, Jay [4 ]
Tsai, Ming-Tzu [5 ]
机构
[1] China Med Univ, Coll Med, Sch Dent, Taichung 404, Taiwan
[2] Taichung Vet Gen Hosp, Dept Orthopaed, Taichung 407, Taiwan
[3] Taichung Vet Gen Hosp, Stem Cell Med Res Ctr, Dept Med Res, Taichung 407, Taiwan
[4] China Med Univ, Dept Biomed Imaging & Radiol Sci, Taichung 404, Taiwan
[5] Hungkuang Univ, Dept Biomed Engn, Taichung 433, Taiwan
关键词
Dental cone-beam computed tomography (dental CBCT); Micro-computed tomography (micro-CT); Bone mineral density (BMD); Trabecular bone structural parameter; Three-point bending; Cortical bone strength; Rat femur; COMPUTED-TOMOGRAPHY; RAT FEMUR; PQCT; DENSITY; INDEX; VALIDATION; GUIDELINES; VALUES;
D O I
10.1016/j.jbiomech.2013.08.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study compared the capabilities of micro-computed tomography (micro-CT) and dental cone-beam computed tomography (CBCT) in assessing trabecular bone parameters and cortical bone strength. Micro-CT and CBCT scans were applied to 28 femurs from 14 rats to obtain independent measurements of the volumetric cancellous bone mineral density (vCanBMD) in the femoral head, volumetric cortical bone mineral density (vCtBMD) in the femoral diaphysis, cross-sectional moment of inertia (CSMI), and bone strength index (BSI) (=CSMI x vCtBMD). Five structural parameters of the trabecular bone of the femoral head were calculated from micro-CT images. A three-point bending test was then conducted to measure the fracture load of each femur. Bivariate linear Pearson analysis was conducted to calculate the correlation coefficients (r values) of the micro-CT, dental CBCT, and three-point bending measurements. The statistical analyses showed a strong correlation between vCanBMD values obtained using micro-CT and dental CBCT (r=0.830). There were strong or moderate correlation between vCanBMD measured using dental CBCT and five parameters of trabecular structure measured using micro-CT. Additionally, the results were satisfactory regardless of whether micro-CT or dental CBCT was used to measure the femoral diaphysis vCtBMD (r=0.733 and 0.680, respectively), CSMI (r=0.756 and 0.726, respectively), or BSI (r=0.846 and 0.847, respectively) to predict fracture loads. This study has yielded a new method for using dental CBCT to evaluate bone parameters and bone strength; however, further studies are necessary to validate the use of dental CBCT on humans. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2611 / 2618
页数:8
相关论文
共 50 条
  • [31] Micro-CT characterization of human trabecular bone in osteogenesis imperfecta
    Jameson, John
    Albert, Carolyne
    Smith, Peter
    Molthen, Robert
    Harris, Gerald
    MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [32] Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography
    He, Rong-Ting
    Tu, Ming-Gene
    Huang, Heng-Li
    Tsai, Ming-Tzu
    Wu, Jay
    Hsu, Jui-Ting
    BMC MEDICAL IMAGING, 2019, 19 (1)
  • [33] Segmentation of Trabecular Jaw Bone on Cone Beam CT Datasets
    Nackaerts, Olivia
    Depypere, Maarten
    Zhang, Guozhi
    Vandenberghe, Bart
    Maes, Frederik
    Jacobs, Reinhilde
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (06) : 1082 - 1091
  • [34] Trabecular microarchitecture after fluoride therapy - Comparison of micro-CT and bone histology.
    Delling, G
    Bruder, J
    Engels, C
    Werner, M
    Minne, HW
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 : S426 - S426
  • [35] Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep
    Aso Muhammad Ali Muhammad
    Norliza Ibrahim
    Rohana Ahmad
    Muhammad Khan Asif
    Zamri Radzi
    Zuraiza Mohamad Zaini
    Hairil Rashmizal Abdul Razak
    BMC Oral Health, 20
  • [36] Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep
    Muhammad, Aso Muhammad Ali
    Ibrahim, Norliza
    Ahmad, Rohana
    Asif, Muhammad Khan
    Radzi, Zamri
    Zaini, Zuraiza Mohamad
    Razak, Hairil Rashmizal Abdul
    BMC ORAL HEALTH, 2020, 20 (01)
  • [37] Iterative reconstruction optimisations for high angle cone-beam micro-CT
    Recur, B.
    Fauconneau, M.
    Kingston, A.
    Myers, G.
    Sheppard, A.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [38] A comparison between micro-CT and histology for the evaluation of cortical bone: effect of polymethylmethacrylate embedding on structural parameters
    Particelli, F.
    Mecozzi, L.
    Beraudi, A.
    Montesi, M.
    Baruffaldi, F.
    Viceconti, M.
    JOURNAL OF MICROSCOPY, 2012, 245 (03) : 302 - 310
  • [39] Influence of micro-CT settings on bone structural parameters
    Schneider, E
    Eckhardt, C
    Lill, C
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 : 45 - 46
  • [40] Comparative evaluation of cone-beam CT equipment with micro-CT in the visualization of root canal system
    Szabo, Bence Tamas
    Pataky, Levente
    Mikusi, Regina
    Fejerdy, Pal
    Dobo-Nagy, Csaba
    ANNALI DELL ISTITUTO SUPERIORE DI SANITA, 2012, 48 (01): : 49 - 52