Correction of coherence gate curvature in high numerical aperture optical coherence imaging

被引:23
|
作者
Graf, Benedikt W. [1 ]
Adie, Steven G. [1 ]
Boppart, Stephen A. [1 ]
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Dept Elect & Comp Engn, Biophoton Imaging Lab, Urbana, IL 61801 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
MULTIPHOTON MICROSCOPY; PHASE;
D O I
10.1364/OL.35.003120
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a method for correcting coherence gate curvature caused by scanning-induced path length variations in spectral-domain high-NA optical coherence imaging systems. These variations cause curvature artifacts in optical coherence tomography and effectively restrict the field of view in optical coherence microscopy (OCM). Here we show that the coherence gate curvature can be measured and corrected by recovering the phase of the analytic signal from a calibration image. This phase information can be used directly to process OCM images allowing the coherence gate curvature, as well as any order of system dispersion, to be corrected in a computationally efficient manner. We also discuss the use of various image quality metrics that can be used to adjust the calibrated phase in order to keep the coherence and confocal gates aligned in tissue. (C) 2010 Optical Society of America
引用
收藏
页码:3120 / 3122
页数:3
相关论文
共 50 条
  • [41] Optical coherence tomography for biomedical imaging
    Fujimoto, J
    Drexler, W
    Li, XD
    Hartl, I
    Chudoba, C
    Morgner, U
    Kärtner, F
    Pitris, C
    Ippen, E
    Brezinski, M
    ULTRAFAST PHENOMENA XII, 2001, 66 : 243 - 247
  • [42] OPTICAL COHERENCE TOMOGRAPHY IN ONCOLOGICAL IMAGING
    Verga, N.
    Mirea, D. A.
    Busca, I
    Poroschianu, M. N.
    Zarma, S. F.
    Grinisteanu, L.
    Anica, A.
    Gheorghe, C. A.
    Stan, C. A.
    Verga, M.
    Vasilache, R.
    ROMANIAN REPORTS IN PHYSICS, 2014, 66 (01) : 75 - 86
  • [43] Speckle Mechanism in Optical Coherence Imaging
    Lin, Haibo
    Yu, Ping
    2007 CONFERENCE ON LASERS & ELECTRO-OPTICS/QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2007), VOLS 1-5, 2007, : 1864 - 1865
  • [44] Optical Coherence Tomography for Ophthalmology Imaging
    Qin, Jia
    An, Lin
    OPTICAL IMAGING IN HUMAN DISEASE AND BIOLOGICAL RESEARCH, 2021, 1355 : 197 - 216
  • [45] Clinical imaging with optical coherence tomography
    Bouma, BE
    Tearney, GJ
    ACADEMIC RADIOLOGY, 2002, 9 (08) : 942 - 953
  • [47] Optical coherence tomography imaging in uveitis
    Onal, Sumru
    Tugal-Tutkun, Ilknur
    Neri, Piergiorgio
    Herbort, Carl P.
    INTERNATIONAL OPHTHALMOLOGY, 2014, 34 (02) : 401 - 435
  • [48] High speed all optical shear wave imaging optical coherence elastography
    Song, Shaozhen
    Hsieh, Bao-Yu
    Wei, Wei
    Shen, Tueng
    O'Donnell, Matthew
    Wang, Ruikang K.
    OPTICAL ELASTOGRAPHY AND TISSUE BIOMECHANICS III, 2016, 9710
  • [49] High speed low coherence interferometer for optical coherence tomography
    Hauger, C
    Wörz, M
    Hellmuth, T
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS VI, 2002, 4619 : 1 - 9
  • [50] Effect of numerical aperture and partial coherence to the resist sidewall angle
    Oh, HK
    Nam, BS
    Baek, SY
    OPTICAL MICROLITHOGRAPHY IX, 1996, 2726 : 323 - 333