Correction of coherence gate curvature in high numerical aperture optical coherence imaging

被引:23
|
作者
Graf, Benedikt W. [1 ]
Adie, Steven G. [1 ]
Boppart, Stephen A. [1 ]
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Dept Elect & Comp Engn, Biophoton Imaging Lab, Urbana, IL 61801 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
MULTIPHOTON MICROSCOPY; PHASE;
D O I
10.1364/OL.35.003120
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a method for correcting coherence gate curvature caused by scanning-induced path length variations in spectral-domain high-NA optical coherence imaging systems. These variations cause curvature artifacts in optical coherence tomography and effectively restrict the field of view in optical coherence microscopy (OCM). Here we show that the coherence gate curvature can be measured and corrected by recovering the phase of the analytic signal from a calibration image. This phase information can be used directly to process OCM images allowing the coherence gate curvature, as well as any order of system dispersion, to be corrected in a computationally efficient manner. We also discuss the use of various image quality metrics that can be used to adjust the calibrated phase in order to keep the coherence and confocal gates aligned in tissue. (C) 2010 Optical Society of America
引用
收藏
页码:3120 / 3122
页数:3
相关论文
共 50 条
  • [21] High resolution imaging with advanced chirp Optical Coherence Tomography
    Hölscher, D
    Kemmer, C
    Rupp, F
    Blazek, V
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS IV, 2000, 3915 : 83 - 89
  • [22] Optical coherence tomography - high resolution imaging of structure and function
    Leitgeb, Rainer A.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 530 - 532
  • [23] Measuring Optical Spatial Coherence by Using a Programmable Aperture
    Choi, Jai-Min
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (01) : 177 - 180
  • [24] Measuring optical spatial coherence by using a programmable aperture
    Jai-Min Choi
    Journal of the Korean Physical Society, 2012, 60 : 177 - 180
  • [25] Amplitude division aperture synthesis optical coherence tomography
    Liu, Linbo
    Bo, En
    Ge, Xin
    Chen, Si
    2020 IEEE PHOTONICS CONFERENCE (IPC), 2020,
  • [26] Numerical correction of coherence gate in full-field swept-source interference microscopy
    Grebenyuk, Anton A.
    Ryabukho, Vladimir P.
    OPTICS LETTERS, 2012, 37 (13) : 2529 - 2531
  • [27] Fresnel diffractive imaging: Experimental study of coherence and curvature
    Whitehead, L. W.
    Williams, G. J.
    Quiney, H. M.
    Nugent, K. A.
    Peele, A. G.
    Paterson, D.
    de Jonge, M. D.
    McNulty, I.
    PHYSICAL REVIEW B, 2008, 77 (10)
  • [28] Optical-coherence tomography, extension to imaging of low coherence interferometry
    Podoleanu, Adrian Gh.
    Cucu, Radu G.
    Rogers, John. A.
    Pedro, Justin
    Dobre, George
    Gomez, Marta
    Liang, Haida
    Amaechi, Ben T.
    Higham, Susan
    ROMOPTO 2006: EIGHTH CONFERENCE ON OPTICS, 2007, 6785
  • [29] Optical coherence tomography and optical coherence tomography angiography imaging in Bietti crystalline dystrophy
    Tiryaki Demir, Semra
    Keles Yesiltas, Sumeyra
    Kacar, Hakan
    Akbas, Emine Betul
    Guven, Dilek
    OPHTHALMIC GENETICS, 2020, 41 (02) : 194 - 197
  • [30] Numerical Aperture and Partial Coherence Optimization in Optical Lithography under Off-axis Illumination
    Guo, Liping
    Fu, Shenggui
    Liu, Xiaojuan
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 2437 - 2442