Geometric Calibration of Cone-beam CT with a Flat-panel Detector

被引:0
|
作者
Wu, Dufan [1 ]
Li, Liang [1 ]
Zhang, Li [1 ]
Xing, Yuxiang [1 ]
Chen, Zhiqiang [1 ]
Xiao, Yongshun [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Here we proposed a method to calibrate several important geometric parameters for cone-beam CT (CBCT) systems. Only three point-like objects and their spatial distances are required for the calibration. Our method is based on the analysis of the ellipse trajectories of the points' projections. Our mathematical expressions are much simpler than similar methods and our method yields better stability. The calibration procedure has been tested on numerical simulations and an actual micro-CT system.
引用
收藏
页码:2952 / 2955
页数:4
相关论文
共 50 条
  • [41] Percutaneous Bone Biopsies: Comparison between Flat-Panel Cone-Beam CT and CT-Scan Guidance
    Lambros Tselikas
    Julien Joskin
    Florian Roquet
    Geoffroy Farouil
    Serge Dreuil
    Antoine Hakimé
    Christophe Teriitehau
    Anne Auperin
    Thierry de Baere
    Frederic Deschamps
    CardioVascular and Interventional Radiology, 2015, 38 : 167 - 176
  • [42] Percutaneous Bone Biopsies: Comparison between Flat-Panel Cone-Beam CT and CT-Scan Guidance
    Tselikas, Lambros
    Joskin, Julien
    Roquet, Florian
    Farouil, Geoffroy
    Dreuil, Serge
    Hakime, Antoine
    Teriitehau, Christophe
    Auperin, Anne
    de Baere, Thierry
    Deschamps, Frederic
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (01) : 167 - 176
  • [43] Fast kV-switching and dual-layer flat-panel detector enabled cone-beam CT joint spectral imaging
    Zhou, Hao
    Zhang, Li
    Wang, Zhilei
    Gao, Hewei
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (11):
  • [44] Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise
    Tilley, Steven, II
    Siewerdsen, Jeffrey H.
    Stayman, J. Webster
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01): : 296 - 319
  • [45] What Is the Diagnostic Accuracy of Flat-panel Cone-beam CT Arthrography for Diagnosis of Scapholunate Ligament Tears?
    Dornberger, Jenny E.
    Rademacher, Grit
    Stengel, Dirk
    Hoenning, Alexander
    Schueler, Gabriele
    Eisenschenk, Andreas
    Mutze, Sven
    Goelz, Leonie
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (01) : 151 - 160
  • [46] Spatial Resolution and Noise Prediction in Flat-Panel Cone-Beam CT Penalized-likelihood Reconstruction
    Wang, W.
    Gang, G. J.
    Siewerdsen, J. H.
    Stayman, J. W.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [47] Geometric Calibration Based on Matrix Calculation for CBCT System with a Flat-panel Detector
    Xu, Xiaofei
    Zhang, Li
    Wu, Dufan
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [48] Feasibility of Using a Grid to Detect and Correct the Geometric Variations in Flat-Panel Based Cone Beam CT
    Zou, G.
    Ren, L.
    Kim, J.
    Jaffray, D.
    Chetty, I.
    Jin, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [49] Image quality advances in flat panel cone-beam CT
    Sowards-Emmerd, David
    Elenbaas, Thijs
    Hansis, Eberhard
    van de Haar, Peter
    Shao, Lingxiong
    Timmer, Jan
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [50] Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    Jaffray, DA
    Siewerdsen, JH
    MEDICAL PHYSICS, 2000, 27 (06) : 1311 - 1323