Percutaneous Bone Biopsies: Comparison between Flat-Panel Cone-Beam CT and CT-Scan Guidance

被引:33
|
作者
Tselikas, Lambros [1 ]
Joskin, Julien [1 ]
Roquet, Florian [2 ]
Farouil, Geoffroy [1 ]
Dreuil, Serge [3 ]
Hakime, Antoine [1 ]
Teriitehau, Christophe [1 ]
Auperin, Anne [2 ]
de Baere, Thierry [1 ]
Deschamps, Frederic [1 ]
机构
[1] Inst Gustave Roussy, Intervent Radiol Dept, F-94805 Villejuif, France
[2] Inst Gustave Roussy, Biostat Dept, F-94805 Villejuif, France
[3] Inst Gustave Roussy, Dept Med Phys, F-94805 Villejuif, France
关键词
Bone biopsy; Guidance modality; Cone beam CT; CT scan; Radiation dose; INTERVENTIONAL RADIOLOGY; RADIOFREQUENCY ABLATION; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY SYSTEM; FLUOROSCOPY; TUMORS; METASTASES; SOFTWARE; ONCOLOGY; MASSES;
D O I
10.1007/s00270-014-0870-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study was designed to compare the accuracy of targeting and the radiation dose of bone biopsies performed either under fluoroscopic guidance using a cone-beam CT with real-time 3D image fusion software (FP-CBCT-guidance) or under conventional computed tomography guidance (CT-guidance). Sixty-eight consecutive patients with a bone lesion were prospectively included. The bone biopsies were scheduled under FP-CBCT-guidance or under CT-guidance according to operating room availability. Thirty-four patients underwent a bone biopsy under FP-CBCT and 34 under CT-guidance. We prospectively compared the two guidance modalities for their technical success, accuracy, puncture time, and pathological success rate. Patient and physician radiation doses also were compared. All biopsies were technically successful, with both guidance modalities. Accuracy was significantly better using FP-CBCT-guidance (3 and 5 mm respectively: p = 0.003). There was no significant difference in puncture time (32 and 31 min respectively, p = 0.51) nor in pathological results (88 and 88 % of pathological success respectively, p = 1). Patient radiation doses were significantly lower with FP-CBCT (45 vs. 136 mSv, p < 0.0001). The percentage of operators who received a dose higher than 0.001 mSv (dosimeter detection dose threshold) was lower with FP-CBCT than CT-guidance (27 vs. 59 %, p = 0.01). FP-CBCT-guidance for bone biopsy is accurate and reduces patient and operator radiation doses compared with CT-guidance.
引用
收藏
页码:167 / 176
页数:10
相关论文
共 50 条
  • [1] Percutaneous Bone Biopsies: Comparison between Flat-Panel Cone-Beam CT and CT-Scan Guidance
    Lambros Tselikas
    Julien Joskin
    Florian Roquet
    Geoffroy Farouil
    Serge Dreuil
    Antoine Hakimé
    Christophe Teriitehau
    Anne Auperin
    Thierry de Baere
    Frederic Deschamps
    CardioVascular and Interventional Radiology, 2015, 38 : 167 - 176
  • [2] Lag correction for flat-panel cone-beam CT in SPECT/CT
    Wang, Jiong
    Hansis, Eberhard
    van de Haar, Peter
    Sowards-Emmerd, David
    Bredno, Joerg
    Shao, Lingxiong
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [3] Geometric Calibration of Cone-beam CT with a Flat-panel Detector
    Wu, Dufan
    Li, Liang
    Zhang, Li
    Xing, Yuxiang
    Chen, Zhiqiang
    Xiao, Yongshun
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2952 - 2955
  • [4] Comparison of flat-panel detector with image-intensifier detector for cone-beam CT
    Baba, R
    Konno, Y
    Ueda, M
    Ikeda, S
    RADIOLOGY, 2000, 217 : 405 - 405
  • [5] Comparison of flat-panel detector and image-intensifier detector for cone-beam CT
    Baba, R
    Konno, Y
    Ueda, K
    Ikeda, S
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (03) : 153 - 158
  • [6] Simulation of Motion Artifacts in Offset Flat-Panel Cone-Beam CT
    Hansis, Eberhard
    Shao, Lingxiong
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2471 - 2475
  • [7] A performance comparison of flat-panel imager-based MV and kV cone-beam CT
    Groh, BA
    Siewerdsen, JH
    Drake, DG
    Wong, JW
    Jaffray, DA
    MEDICAL PHYSICS, 2002, 29 (06) : 967 - 975
  • [8] Noise, sampling, and the number of projections in cone-beam CT with a flat-panel detector
    Zhao, Z.
    Gang, G. J.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [9] Iterative Reconstruction for Circular Cone-Beam CT with an Offset Flat-Panel Detector
    Hansis, Eberhard
    Bredno, Joerg
    Sowards-Emmerd, David
    Shao, Lingxiong
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2228 - 2231
  • [10] Microcalcification detection using cone-beam CT mammography with a flat-panel imager
    Gong, X
    Vedula, AA
    Glick, SJ
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11): : 2183 - 2195