Dose monitoring and output correction for the effects of scanning field changes with uniform scanning proton beam

被引:1
|
作者
Zhao, Qingya [1 ,2 ]
Wu, Huanmei [3 ]
Cheng, Chee-Wai [1 ,4 ]
Das, Indra J. [1 ,4 ]
机构
[1] IUHPTC, Bloomington, IN 47408 USA
[2] Purdue Univ, Sch Hlth Sci, W Lafayette, IN 47907 USA
[3] IUPUI, Purdue Sch Engn & Technol, Indianapolis, IN 46202 USA
[4] Indiana Univ, Dept Radiat Oncol, Sch Med, Indianapolis, IN 46202 USA
关键词
uniform scanning proton beam; dose monitor; stem effect; proton output calculation; BRAGG PEAK FIELDS; UNIT CALCULATIONS; THERAPY; DOSIMETRY; RANGE;
D O I
10.1118/1.3609417
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The output of a proton beam is affected by proton energy, Spread-Out Bragg Peak (SOBP) width, aperture size, dose rate, and the point of measurement. In a uniform scanning proton beam (USPB), the scanning field size is adjusted (including the vertical length and the horizontal width) according to the treatment field size with appropriate margins to reduce secondary neutron production. Different scanning field settings result in beam output variations that are investigated in this study. Methods: The measurements are performed with a parallel plate Markus chamber at the center of SOBP under the reference condition with 16 cm range, 10 cm SOBP, and 5 cm air gap. The effect of dose rate on field output is studied by varying proton beam current from 0.5 to 7 nA. The effects of scanning field settings are studied by varying independently the field width and length from 12 x 12 to 30 x 30 cm(2). Results: The results demonstrate that scanning field variations can produce output variation up to 3.80%. In addition, larger output variation is observed with scanning field changes along the stem direction of the patient dose monitor (PDM). By investigating the underlying physics of incomplete charge collection and the stem effects of the PDM, an analytical model is proposed to calculate USPB output with consideration of the scanning field area and the PDM stem length that is irradiated. The average absolute difference between the measured output and calculated output using our new correction model are within 0.13 and 0.08% for the 20 and 30 cm snouts, respectively. Conclusions: This study proposes a correction model for accurate USPB output calculation, which takes account of scanning field settings and the PDM stem effects. This model may be used to extend the existing output calculation model from one snout size to other snout sizes with customized scanning field settings. The study is especially useful for calculating field output for treatment without individualized patient specific measurements. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3609417]
引用
收藏
页码:4655 / 4661
页数:7
相关论文
共 50 条
  • [31] On the Equivalence of the Quality Correction Factor for Pencil Beam Scanning Proton Therapy
    Sorriaux, J.
    Paganetti, H.
    Testa, M.
    Giantsoudi, D.
    Schuemann, J.
    Bertrand, D.
    de Xivry, J. Orban
    Lee, J.
    Palmans, H.
    Vynckier, S.
    Sterpin, E.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 333 - 333
  • [32] Patient specific dosimetry and quality assurance for an active uniform scanning proton beam
    Mascia, A. E.
    Wolanski, M.
    Jesseph, R.
    Nichiporov, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S652 - S652
  • [33] Respiratory Motion Management of Liver Cancer in Uniform Scanning Proton Beam Therapy
    Akino, Y.
    Das, I. J.
    Wu, H.
    Oh, R.
    Inoue, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S915 - S916
  • [34] Development and Performance Analysis of Scanning Proton Beam Dose Distribution Imager
    Yang, Feng
    Zhang, Xiang
    Zhou, Rong
    Yang, Chaowen
    [J]. Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2019, 53 (12): : 2485 - 2490
  • [35] A Practical Experience of Dose Modeling for Proton Pencil Beam Scanning in KNCC
    Jo, Kwanghyun
    Kim, Mi Young
    Jeong, Jong Hwi
    Jeang, EunHee
    Kim, Haksoo
    Park, Seyjoon
    Park, Jeong-Hoon
    Lim, Young Kyung
    Shin, Dongho
    Lee, Se Byeong
    Jo, Kwanghyun
    Jeong, Chiyoung
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 108 - 115
  • [36] Monte Carlo Computation of the Effective Dose in Scanning Beam Proton Therapy
    Mirkovic, D.
    Titt, U.
    Sawakuchi, G.
    Zhang, X.
    Li, Y.
    Mohan, R.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [37] A practical experience of dose modeling for proton pencil beam scanning in KNCC
    Kwanghyun Jo
    Mi Young Kim
    Jong Hwi Jeong
    EunHee Jeang
    Haksoo Kim
    Seyjoon Park
    Jeong-Hoon Park
    Young Kyung Lim
    Dongho Shin
    Se Byeong Lee
    Kwanghyun Jo
    Chiyoung Jeong
    [J]. Journal of the Korean Physical Society, 2015, 67 : 108 - 115
  • [38] Monte Carlo Dose Verification of Pencil Beam Scanning Proton Therapy
    Giantsoudi, D.
    Clasie, B.
    Grassberger, C.
    Dowdell, S.
    Depauw, N.
    Madden, T.
    Kooy, H.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [39] Measurements of neutron dose equivalent for a proton therapy center using uniform scanning proton beams
    Zheng, Yuanshui
    Liu, Yaxi
    Zeidan, Omar
    Schreuder, Andries Niek
    Keole, Sameer
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3484 - 3492
  • [40] Comparasion of Entrance Dose of Uniform Scanning and Double Scattering Modes in Proton Therapy
    Zhao, Z.
    Li, Z.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)