Validation of NEMA NU4-2008 Scatter Fraction estimation with 18F and 68Ga for the ARGUS small-animal PET scanner

被引:0
|
作者
Vicente, E. [1 ,2 ]
Herraiz, J. L. [1 ]
Canadas, M. [3 ]
Cal-Gonzalez, J. [1 ]
Espana, S. [4 ,5 ]
Desco, M. [6 ,7 ,8 ]
Vaquero, J. J. [6 ]
Udias, J. M. [1 ]
机构
[1] Univ Complutense Madrid, Dpto Fis Atom Mol & Nucl, Grp Fis Nucl, E-28040 Madrid, Spain
[2] CSIC, Inst Estruct Mat, Madrid, Spain
[3] CIEMAT Ctr Invest Energeticas Medioambientales &, Madrid, Spain
[4] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA USA
[5] Harvard Med Sch, Boston, MA USA
[6] Univ Carlos III Madrid, Dept Bioingn & Ingn Aeroesp, Madrid, Spain
[7] Univ Gregorio Maranon, Gen Hosp, Unidad Med & Cirugia Expt, Madrid, Spain
[8] Inst Salud Carlos III, CIBERSAM, Madrid, Spain
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The scatter fraction (SF) in PET data represents the fraction of coincidence events in which at least one of the two emitted photons have been scattered before being detected. It is usually estimated as the ratio of scattered events to total number of coincidences, when the number of random counts is negligible (less than 1% of true rates). SF provides a measurement of the relative sensitivity of the scanner to scattered radiation. It depends on object size, density and location inside the field of view, as well as on detector size, type of detector crystal and energy window. The performance evaluation guideline for small-animal PET NEMA (National Electrical Manufacturers Association) NU4-2008 proposes the estimation of the SF for three test phantoms made in proportion to the most widely used small animals in the laboratory: mouse, rat and monkey. The method estimates the different coincidence types in sinogram profiles from an off-centered line source inserted in these phantoms. We benchmark the procedure proposed by NEMA to estimate SF with F-18 and also with Ga-68, a radionuclide with lager positron range. Real data acquired with the ARGUS small-animal PET scanner (SEDECAL, Madrid, Spain) as well as simulations of the same scanner with peneloPET are used. The results show that, though SF should be practically the same with both F-18 and Ga-68 isotopes (and indeed our simulations indicate this) NEMA SF estimations with Ga-68 acquisitions are higher. This is due to the fact that Ga-68 positron range affects on the width of the line source profiles. Suggestions to modify the protocol to obtain similar SF estimations when using isotopes with larger positron range than F-18 are made.
引用
收藏
页码:3553 / 3557
页数:5
相关论文
共 41 条
  • [31] Preliminary evidence of imaging of chemokine receptor-4-targeted PET/CT with [68Ga]pentixafor in non-Hodgkin lymphoma: comparison to [18F]FDG
    Qingqing Pan
    Yaping Luo
    Yan Zhang
    Long Chang
    Ji Li
    Xinxin Cao
    Jian Li
    Fang Li
    EJNMMI Research, 10
  • [32] Preliminary evidence of imaging of chemokine receptor-4-targeted PET/CT with [68Ga]pentixafor in non-Hodgkin lymphoma: comparison to [18F]FDG
    Pan, Qingqing
    Luo, Yaping
    Zhang, Yan
    Chang, Long
    Li, Ji
    Cao, Xinxin
    Li, Jian
    Li, Fang
    EJNMMI RESEARCH, 2020, 10 (01)
  • [33] Contrast-enhanced small-animal PET/CT in cancer research: strong improvement of diagnostic accuracy without significant alteration of quantitative accuracy and NEMA NU 4-2008 image quality parameters
    Lasnon, Charline
    Quak, Elske
    Briand, Melanie
    Gu, Zheng
    Louis, Marie-Helene
    Aide, Nicolas
    EJNMMI RESEARCH, 2013, 3 : 1 - 11
  • [34] Evaluation of brain SERT occupancy by resveratrol against MDMA-induced neurobiological and behavioral changes in rats: A 4-[18F]-ADAM/small-animal PET study
    Shih, Jui-Hu
    Ma, Kuo-Hsing
    Chen, Chien-Fu F.
    Cheng, Cheng-Yi
    Pao, Li-Heng
    Weng, Shao-Ju
    Huang, Yuahn-Sieh
    Shiue, Chyng-Yann
    Yeh, Ming-Kung
    Li, I-Hsun
    EUROPEAN NEUROPSYCHOPHARMACOLOGY, 2016, 26 (01) : 92 - 104
  • [35] [68Ga] pentixafor for CXCR4 imaging in a PC-3 prostate cancer xenograft model - comparison with [18F]FDG PET/CT, MRI and ex vivo receptor expression
    Schwarzenboek, Sarah M.
    Stenzel, Jan
    Otto, Thomas
    Helldorff, Heike V.
    Bergner, Carina
    Kurth, Jens
    Polei, Stefan
    Lindner, Tobias
    Rauer, Romina
    Hohn, Alexander
    Hakenberg, Oliver W.
    Wester, Hans J.
    Vollmar, Brigitte
    Krause, Bernd J.
    ONCOTARGET, 2017, 8 (56) : 95606 - 95619
  • [36] Comparison of: (2S,4R)-4-[18F]Fluoroglutamine, [11C]Methionine, and 2-Deoxy-2-[18F]Fluoro-D-Glucose and Two Small-Animal PET/CT Systems Imaging Rat Gliomas
    Miner, Maxwell W. G.
    Liljenback, Heidi
    Virta, Jenni
    Helin, Semi
    Eskola, Olli
    Elo, Petri
    Teuho, Jarmo
    Seppala, Kerttu
    Oikonen, Vesa
    Yang, Guangli
    Kindler-Roehrborn, Andrea
    Minn, Heikki
    Li, Xiang-Guo
    Roivainen, Anne
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [37] [68Ga]Pentixafor for CXCR4 Imaging in a PC-3 Prostate Cancer Xenograft Model - comparison with [18F]FDG PET/CT, MRI and ex-vivo receptor expression
    Schwarzenboeck, S. M.
    Stenzel, J.
    Otto, T.
    Kurth, J.
    Polei, S.
    Lindner, T.
    Hohn, A.
    Wester, H.
    Vollmar, B.
    Krause, B. J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S39 - S39
  • [38] Influence of spill-over for 99mTc images and the effect of scatter correction for dual-isotope simultaneous acquisition with 99mTc and 18F using small-animal SPECT-PET/CT system
    Shibutani, Takayuki
    Onoguchi, Masahisa
    Kanno, Takayuki
    Kinuya, Seigo
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (01) : 135 - 142
  • [39] Influence of spill-over for 99mTc images and the effect of scatter correction for dual-isotope simultaneous acquisition with 99mTc and 18F using small-animal SPECT-PET/CT system
    Takayuki Shibutani
    Masahisa Onoguchi
    Takayuki Kanno
    Seigo Kinuya
    Physical and Engineering Sciences in Medicine, 2024, 47 : 135 - 142
  • [40] Authors' reply to Dr. Paolo Duarte: Combined [68Ga]Ga-PSMA-11 and low-dose [18F]FDG PET/CT using a long-axial field of view scanner for patients referred for [177Lu]-PSMA-radioligand therapy
    Alberts, Ian
    Schepers, Robin
    Zeimpekis, Konstantinos
    Sari, Hasan
    Rominger, Axel
    Afshar-Oromieh, Ali
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (03) : 644 - 647