Contrast-enhanced small-animal PET/CT in cancer research: strong improvement of diagnostic accuracy without significant alteration of quantitative accuracy and NEMA NU 4-2008 image quality parameters

被引:5
|
作者
Lasnon, Charline [1 ,2 ]
Quak, Elske [3 ]
Briand, Melanie [1 ,2 ]
Gu, Zheng [4 ]
Louis, Marie-Helene [1 ,2 ]
Aide, Nicolas [1 ,2 ,3 ]
机构
[1] Normandie Univ, F-14000 Caen, France
[2] Francois Baclesse Canc Ctr, IFR 146, EA 4656, BioTICLA Team, F-14076 Caen 5, France
[3] Francois Baclesse Canc Ctr, Dept Nucl Med, F-14076 Caen, France
[4] Univ Calif Los Angeles, Biomed Phys Program, Los Angeles, CA 90024 USA
来源
EJNMMI RESEARCH | 2013年 / 3卷
关键词
Small-animal PET/CT; Contrast media; NEMA NU 4-2008; Tumor-bearing rodents; Quantification;
D O I
10.1186/2191-219X-3-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The use of iodinated contrast media in small-animal positron emission tomography (PET)/computed tomography (CT) could improve anatomic referencing and tumor delineation but may introduce inaccuracies in the attenuation correction of the PET images. This study evaluated the diagnostic performance and accuracy of quantitative values in contrast-enhanced small-animal PET/CT (CEPET/CT) as compared to unenhanced small animal PET/CT (UEPET/CT). Methods: Firstly, a NEMA NU 4-2008 phantom (filled with F-18-FDG or F-18-FDG plus contrast media) and a homemade phantom, mimicking an abdominal tumor surrounded by water or contrast media, were used to evaluate the impact of iodinated contrast media on the image quality parameters and accuracy of quantitative values for a pertinent-sized target. Secondly, two studies in 22 abdominal tumor-bearing mice and rats were performed. The first animal experiment studied the impact of a dual-contrast media protocol, comprising the intravenous injection of a long-lasting contrast agent mixed with F-18-FDG and the intraperitoneal injection of contrast media, on tumor delineation and the accuracy of quantitative values. The second animal experiment compared the diagnostic performance and quantitative values of CEPET/CT versus UEPET/CT by sacrificing the animals after the tracer uptake period and imaging them before and after intraperitoneal injection of contrast media. Results: There was minimal impact on IQ parameters (%SDunif and spillover ratios in air and water) when the NEMA NU 4-2008 phantom was filled with F-18-FDG plus contrast media. In the homemade phantom, measured activity was similar to true activity (-0.02%) and overestimated by 10.30% when vials were surrounded by water or by an iodine solution, respectively. The first animal experiment showed excellent tumor delineation and a good correlation between small-animal (SA)-PET and ex vivo quantification (r(2) = 0.87, P < 0.0001). The second animal experiment showed a good correlation between CEPET/CT and UEPET/CT quantitative values (r(2) = 0.99, P < 0.0001). Receiver operating characteristic analysis demonstrated better diagnostic accuracy of CEPET/CT versus UEPET/CT (senior researcher, area under the curve (AUC) 0.96 versus 0.77, P = 0.004; junior researcher, AUC 0.78 versus 0.58, P = 0.004). Conclusions: The use of iodinated contrast media for small-animal PET imaging significantly improves tumor delineation and diagnostic performance, without significant alteration of SA-PET quantitative accuracy and NEMA NU 4-2008 IQ parameters.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 9 条
  • [1] Contrast-enhanced small-animal PET/CT in cancer research: strong improvement of diagnostic accuracy without significant alteration of quantitative accuracy and NEMA NU 4–2008 image quality parameters
    Charline Lasnon
    Elske Quak
    Mélanie Briand
    Zheng Gu
    Marie-Hélène Louis
    Nicolas Aide
    EJNMMI Research, 3
  • [2] Technical Note: Performance evaluation of a small-animal PET/CT system based on NEMA NU 4-2008 standards
    Liu, Qiong
    Li, Chaofan
    Liu, Jiguo
    Krish, Kishore
    Fu, Xinlei
    Zhao, Jie
    Chen, Jyh-Cheng
    MEDICAL PHYSICS, 2021, 48 (09) : 5272 - 5282
  • [3] Investigation of Image Reconstruction Parameters of the Mediso nanoScan PC Small-Animal PET/CT Scanner for Two Different Positron Emitters Under NEMA NU 4-2008 Standards
    Anastasios Gaitanis
    George A. Kastis
    Elena Vlastou
    Penelope Bouziotis
    Panayotis Verginis
    Constantinos D. Anagnostopoulos
    Molecular Imaging and Biology, 2017, 19 : 550 - 559
  • [4] Investigation of Image Reconstruction Parameters of the Mediso nanoScan PC Small-Animal PET/CT Scanner for Two Different Positron Emitters Under NEMA NU 4-2008 Standards
    Gaitanis, Anastasios
    Kastis, George A.
    Vlastou, Elena
    Bouziotis, Penelope
    Verginis, Panayotis
    Anagnostopoulos, Constantinos D.
    MOLECULAR IMAGING AND BIOLOGY, 2017, 19 (04) : 550 - 559
  • [5] Image-Quality Assessment for Several Positron Emitters Using the NEMA NU 4-2008 Standards in the Siemens Inveon Small-Animal PET Scanner
    Disselhorst, Jonathan A.
    Brom, Maarten
    Laverman, Peter
    Slump, Cornelius H.
    Boerman, Otto C.
    Oyen, Wim J. G.
    Gotthardt, Martin
    Visser, Eric P.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (04) : 610 - 617
  • [6] Characterization and optimization of image quality as a function of reconstruction algorithms and parameter settings in a Siemens Inveon small-animal PET scanner using the NEMA NU 4-2008 standards
    Visser, Eric P.
    Disselhorst, Jonathan A.
    van Lier, Monique G. J. T. B.
    Laverman, Peter
    de Jong, Gabie M.
    Oyen, Wim J. G.
    Boerman, Otto C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 629 (01): : 357 - 367
  • [7] Image quality assessment for several positron emitters using the NEMA NU 4 2008 standards in the Inveon small-animal PET scanner
    Disselhorst, Jonathan
    Brom, Maarten
    Laverman, Peter
    Slump, Cornelis
    Boerman, Otto
    Oyen, Wim
    Gotthardt, Martin
    Visser, Eric
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [8] Using the NEMA-NU4 image quality phantom to optimize small animal PET/CT reconstructions: validation for therapy assessment in cancer research
    Lasnon, C.
    Dugue, A.
    Briand, M.
    Louis, M.
    Aide, N.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S637 - S637
  • [9] Image quality as a function of reconstruction algorithms and their parameter settings for the Siemens Inveon small-animal PET scanner evaluated using the NEMA NU4 2008 standards
    Visser, E. P.
    Disselhorst, J. A.
    van Lier, M. G. J. T.
    Laverman, P.
    Gotthardt, M.
    Oyen, W. J. G.
    Boerman, O. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S171 - S171