Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers

被引:26
|
作者
Spezi, E [1 ]
Lewis, DG [1 ]
Smith, CW [1 ]
机构
[1] Velindre Hosp, Dept Med Phys, Cardiff CF14 2TL, S Glam, Wales
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2001年 / 46卷 / 11期
关键词
D O I
10.1088/0031-9155/46/11/316
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6 MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles along both wedged and unwedged directions for different depths and focus-to-surface distances. Furthermore, Monte Carlo-generated output factors for both open and wedged fields agreed with linac commissioning beam data within statistical uncertainties of the calculations (<3% at largest depths). Compensating filters of both low-density and high-density materials have also been successfully simulated. As a demonstration, a wax compensating filter with a complex three-dimensional concave and convex geometry has been modelled through a CT scan import. Calculated depth doses and lateral dose profiles for different field sizes agreed well with experiments. The code was used to investigate the performance of a commercial treatment planning system in designing compensators. Dose distributions in a heterogeneous water phantom emulating the head and neck region were calculated with the convolution-superposition method (pencil beam and collapsed cone implementations) and compared against those from the MC code developed herein. The new technique presented in this work is versatile, DICOM-RT compliant and accurate in the simulation of beam modulators. This paper addresses the need to reduce the sources of error in the modelling of beam modifiers since they remain a viable alternative to the MLC technique in the delivery of IMRT beams.
引用
收藏
页码:3007 / 3029
页数:23
相关论文
共 50 条
  • [21] Monte Carlo simulation of complex radiotherapy treatments
    Leal, A
    Sánchez-Doblado, F
    Arrans, R
    Perucha, M
    Rincón, M
    Carrasco, E
    Bernal, C
    [J]. COMPUTING IN SCIENCE & ENGINEERING, 2004, 6 (04) : 60 - 68
  • [22] Dosimetric verification of small fields in the lung using lung-equivalent polymer gel and Monte Carlo simulation
    Gharehaghaji, Nahideh
    Dadgar, Habib Alah
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2018, 14 (02) : 278 - 286
  • [23] Monte Carlo verification of gel dosimetry measurements for stereotactic radiotherapy
    Kairn, T.
    Taylor, M. L.
    Crowe, S. B.
    Dunn, L.
    Franich, R. D.
    Kenny, J.
    Knight, R. T.
    Trapp, J. V.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (11): : 3359 - 3369
  • [24] Monte Carlo computer simulation of a camera system for proton beam range verification in cancer treatment
    Sun, Xiao-Li
    Wang, Hui
    Li, Xin-Ke
    Cao, Guo-Hong
    Kuang, Yu
    Zhang, Xiao-Chen
    [J]. FUTURE GENERATION COMPUTER SYSTEMS-THE INTERNATIONAL JOURNAL OF ESCIENCE, 2020, 102 : 978 - 991
  • [25] The PADME beam line Monte Carlo simulation
    Bossi, F.
    Branchini, P.
    Buonomo, B.
    Capirossi, V
    Caricato, A. P.
    Chiodini, G.
    De Sangro, R.
    Di Giulio, C.
    Domenici, D.
    Ferrarotto, F.
    Fiore, S.
    Finocchiaro, G.
    Foggetta, L. G.
    Frankenthal, A.
    Garattini, M.
    Georgiev, G.
    Ghigo, A.
    Gianotti, P.
    Iazzi, F.
    Ivanov, S.
    Ivanov, Sv
    Kozhuharov, V
    Leonardi, E.
    Long, E.
    Martino, M.
    Oceano, I
    Oliva, F.
    Organtini, G. C.
    Pinna, F.
    Piperno, G.
    Raggi, M.
    Sarra, I
    Simeonov, R.
    Spadaro, T.
    Spagnolo, S.
    Spiriti, E.
    Tagnani, D.
    Taruggi, C.
    Valente, P.
    Variola, A.
    Vilucchi, E.
    [J]. JOURNAL OF HIGH ENERGY PHYSICS, 2022, 2022 (09)
  • [26] The PADME beam line Monte Carlo simulation
    F. Bossi
    P. Branchini
    B. Buonomo
    V. Capirossi
    A. P. Caricato
    G. Chiodini
    R. De Sangro
    C. Di Giulio
    D. Domenici
    F. Ferrarotto
    S. Fiore
    G. Finocchiaro
    L. G. Foggetta
    A. Frankenthal
    M. Garattini
    G. Georgiev
    A. Ghigo
    P. Gianotti
    F. Iazzi
    S. Ivanov
    Sv. Ivanov
    V. Kozhuharov
    E. Leonardi
    E. Long
    M. Martino
    I. Oceano
    F. Oliva
    G. C. Organtini
    F. Pinna
    G. Piperno
    M. Raggi
    I. Sarra
    R. Simeonov
    T. Spadaro
    S. Spagnolo
    E. Spiriti
    D. Tagnani
    C. Taruggi
    P. Valente
    A. Variola
    E. Vilucchi
    [J]. Journal of High Energy Physics, 2022
  • [27] SBRT Dose Verification Using Monte Carlo Simulation
    Luo, W.
    Xie, X.
    McGarry, R.
    Molloy, J.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3796 - 3796
  • [28] BEAMnrc Monte Carlo code for dosimetric characterization of a IORT electron beam
    Aragno, D.
    Rauco, R.
    Raza, G.
    El Gawhary, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S221 - S222
  • [29] Dosimetric verification of breast IMRT treatment planning using Monte Carlo method
    Gagne, I.
    Zavgorodni, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S224 - S225
  • [30] Dosimetric accuracy assessment of a treatment plan verification system for scanned proton beam radiotherapy: one-year experimental results and Monte Carlo analysis of the involved uncertainties
    Molinelli, S.
    Mairani, A.
    Mirandola, A.
    Freixas, G. Vilches
    Tessonnier, T.
    Giordanengo, S.
    Parodi, K.
    Ciocca, M.
    Orecchia, R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (11): : 3837 - 3847