Monte Carlo computer simulation of a camera system for proton beam range verification in cancer treatment

被引:4
|
作者
Sun, Xiao-Li [1 ]
Wang, Hui [2 ]
Li, Xin-Ke [1 ]
Cao, Guo-Hong [3 ,4 ]
Kuang, Yu [2 ]
Zhang, Xiao-Chen [1 ]
机构
[1] Zhejiang Univ, Affiliated Hosp 1, Dept Radiat Oncol, Sch Med, Hangzhou 310003, Zhejiang, Peoples R China
[2] Univ Nevada, Med Phys Program, Las Vegas, NV 89154 USA
[3] Zhejiang Univ, Affiliated Hosp 1, Dept Radiol, Sch Med, Hangzhou 310003, Zhejiang, Peoples R China
[4] Shulan Hangzhou Hosp, Dept Radiol, Hangzhou 330103, Zhejiang, Peoples R China
关键词
Computer distributed computing; Computer simulation; Parallel computing; Monte Carlo modeling; Proton beam range verification; SLIT CAMERA; PARALLEL; PHYSICS; THERAPY; TOOLKIT;
D O I
10.1016/j.future.2019.09.011
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Purpose: This paper investigated a framework to efficiently compute and merge Monte Carlo simulations with new technique development in cancer treatment. A newly designed 3-D prompt gamma (PG) camera system was developed using Monte Carlo computer simulation method to validate the utility of the camera simulated for in-beam proton range verification during cancer treatment. Materials and Methods: We used the TOPAS Monte Carlo code to model a 3-D PG slit-camera system based on pixelated cadmium zinc telluride (CZT) semiconductor detectors. The hierarchy structure of the system modeling includes a top level parameter file and a set of low level parameter files needed to specify particle source, physics setting, geometry, scoring, time-dependent motion, data and graphical output of the system. A high-performance computer cluster to perform the timeconsuming computing was used. The effectiveness of the Monte Carlo computer simulation for the system modeling was assessed through statistical simulation experiments. The energy spectra detected by the CZT camera were simulated by irradiating a polymethyl methacrylate (PMMA) phantom with a proton beam of 160 MeV. The axial beam shifting within the PMMA phantom and ranges of the distal beam spots of C-Shape dose distribution in the TG-119 phantom were measured by the modeled camera, respectively. Through simulating a double-head slit camera system, the transverse positions of the proton beam spots were determined based on the measurement of time of flights of photons from positron annihilation events induced by protons within patient. Results: The results from the Monte Carlo computer simulation showed that the energy spectra detected by the CZT camera consisted of main characteristic peaks, including the 4.44 MeV peak from de-excitation of C-12 and the 511 KeV peak from positron annihilation interaction. The gamma emission between 4.0 to 5.0 MeV contributed to the majority of the detected profiles. In the PMMA phantom experiments with 2.2 x 10(8) protons at 160 MeV simulated, a 1 mm standard deviation on range estimation was achieved. With the collimator at 25 cm away from the beam axis, a less than 3 mm standard deviation on range estimation in TG-119 phantom for the individual distal beam spots was obtained. Using the time-of-flight method, the transverse position accuracy of the beam spot measured was less than 1 cm using the simulated double-head camera. Conclusions: The study demonstrated the effectiveness of Monte Carlo computer simulation framework to model the proton beam range monitoring process. Moreover, the computationally modeled proton range verification capability using the 3-D PG camera system, with millimeter accuracy, can be readily translated from computer modeling to medical practice. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:978 / 991
页数:14
相关论文
共 50 条
  • [1] Comparison of knife-edge and multi-slit camera for proton beam range verification by Monte Carlo simulation
    Park, Jong Hoon
    Kim, Sung Hun
    Ku, Youngmo
    Lee, Hyun Su
    Kim, Chan Hyeong
    Shin, Dong Ho
    Jeong, Jong Hwi
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2019, 51 (02) : 533 - 538
  • [2] Development of focusing multi-knife-edge camera for proton beam range verification: A Monte Carlo study
    Chiang, Chih-Chieh
    Wang, Bo-Yao
    Liu, Chun-Yu
    Nemallapudi, Mythra Varun
    Lin, Hsin-Hon
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2024, 217
  • [3] Proton range verification in inhomogeneous tissue: Treatment planning system vs. measurement vs. Monte Carlo simulation
    Kim, Dae-Hyun
    Cho, Sungkoo
    Jo, Kwanghyun
    Shin, EunHyuk
    Hong, Chae-Seon
    Han, Youngyih
    Suh, Tae-Suk
    Lim, Do Hoon
    Choi, Doo Ho
    [J]. PLOS ONE, 2018, 13 (03):
  • [4] Feasibility of on-line multiple scanning proton beam range verification with PET imaging: Monte Carlo simulation studies
    Zhong, Yuncheng
    Lu, Weiguo
    Jia, Xun
    Shao, Yiping
    [J]. 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [5] Monte Carlo PET Camera Modelling for Proton Range Evaluation in Proton Therapy
    Claire Van Ngoc Ty
    De Marzi, Ludovic
    Jan, Sebastien
    Lestand, Loic
    Ferrand, Regis
    Comtat, Claude
    Trebossen, Regine
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3501 - 3504
  • [6] Monte Carlo simulation of a therapeutical proton beam line
    Russo, S
    Bucciolini, M
    Compagnucci, A
    Mazal, A
    Nauraye, C
    Rosenwald, JC
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 1998, 14 (02): : 63 - 71
  • [7] Monte Carlo Modeling and Simulation of a Passive Treatment Proton Beam Delivery System using a Modulation Wheel
    Shin, Jungwook
    Kim, Dongwook
    Lim, Young Kyung
    Ahn, Sunghwan
    Shin, Dongho
    Yoon, Myong Geun
    Park, Sung-Yong
    Lee, Se Byeong
    Kwak, Jungwon
    Son, Dongchul
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2010, 56 (01) : 153 - 163
  • [8] Accuracy of using high-energy prompt gamma to verify proton beam range with a Compton camera: A Monte Carlo simulation study
    Huang, Hsuan-Ming
    Jan, Meei-Ling
    [J]. APPLIED RADIATION AND ISOTOPES, 2018, 142 : 173 - 180
  • [9] Verification of a beam model in a treatment planninng system using an Monte Carlo approach
    Wieslander, E.
    Knoos, T.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2504 - 2504
  • [10] Monte Carlo based verification of a beam model used in a treatment planning system
    Wieslander, E.
    Knoos, T.
    [J]. INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102