Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers

被引:26
|
作者
Spezi, E [1 ]
Lewis, DG [1 ]
Smith, CW [1 ]
机构
[1] Velindre Hosp, Dept Med Phys, Cardiff CF14 2TL, S Glam, Wales
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2001年 / 46卷 / 11期
关键词
D O I
10.1088/0031-9155/46/11/316
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6 MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles along both wedged and unwedged directions for different depths and focus-to-surface distances. Furthermore, Monte Carlo-generated output factors for both open and wedged fields agreed with linac commissioning beam data within statistical uncertainties of the calculations (<3% at largest depths). Compensating filters of both low-density and high-density materials have also been successfully simulated. As a demonstration, a wax compensating filter with a complex three-dimensional concave and convex geometry has been modelled through a CT scan import. Calculated depth doses and lateral dose profiles for different field sizes agreed well with experiments. The code was used to investigate the performance of a commercial treatment planning system in designing compensators. Dose distributions in a heterogeneous water phantom emulating the head and neck region were calculated with the convolution-superposition method (pencil beam and collapsed cone implementations) and compared against those from the MC code developed herein. The new technique presented in this work is versatile, DICOM-RT compliant and accurate in the simulation of beam modulators. This paper addresses the need to reduce the sources of error in the modelling of beam modifiers since they remain a viable alternative to the MLC technique in the delivery of IMRT beams.
引用
收藏
页码:3007 / 3029
页数:23
相关论文
共 50 条
  • [1] Simulation of beam modifiers for Monte Carlo treatment planing
    Li, JS
    Pawlicki, T
    Deng, J
    Jiang, SB
    Ma, CM
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 437 - 439
  • [2] An integrated Monte Carlo dosimetric verification system for radiotherapy treatment planning
    Yamamoto, T.
    Mizowaki, T.
    Miyabe, Y.
    Takegawa, H.
    Narita, Y.
    Yano, S.
    Nagata, Y.
    Teshima, T.
    Hiraoka, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (07): : 1991 - 2008
  • [3] Dosimetric verification of a Monte Carlo electron beam model for an add-on eMLC
    Vatanen, T.
    Traneus, E.
    Lahtinen, T.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (02): : 391 - 404
  • [4] Dosimetric comparison of pencil beam and Monte Carlo algorithms in conformal lung radiotherapy
    Elcim, Yelda
    Dirican, Bahar
    Yavas, Omer
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 616 - 624
  • [5] A Monte Carlo simulation and dosimetric verification of physical wedges used in radiation therapy
    Momennezhad, M.
    Toosi, M. T. Bahreyni
    Sadeghi, R.
    Gholamhoseinian, H.
    Nasserr, Sh
    [J]. IRANIAN JOURNAL OF RADIATION RESEARCH, 2010, 7 (04): : 223 - 227
  • [6] Monte Carlo Simulation of In Vivo Verification for Small Aperture Electron Radiotherapy
    Li, K.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E249 - E249
  • [7] Dosimetric validation of the MCNPX Monte Carlo simulation for radiobiologic studies of megavoltage grid radiotherapy
    Zhang, Hualin
    Johnson, Ellis L.
    Zwicker, Robert D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (05): : 1576 - 1583
  • [8] Monte Carlo verification of radiotherapy treatments with CloudMC
    Hector Miras
    Rubén Jiménez
    Álvaro Perales
    José Antonio Terrón
    Alejandro Bertolet
    Antonio Ortiz
    José Macías
    [J]. Radiation Oncology, 13
  • [9] Monte Carlo verification of radiotherapy treatments with CloudMC
    Miras, Hector
    Jimenez, Ruben
    Perales, Alvaro
    Terron, Jose Antonio
    Bertolet, Alejandro
    Ortiz, Antonio
    Macias, Jose
    [J]. RADIATION ONCOLOGY, 2018, 13
  • [10] Dosimetric verification for intensity-modulated radiotherapy of thoracic cancers using experimental and Monte Carlo approaches
    Jang, Si Young
    Liu, H. Helen
    Wang, Xiaochun
    Vassiliev, Oleg N.
    Siebers, Jeffrey V.
    Dong, Lei
    Mohan, Radhe
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : 939 - 948