Axial Behavior of Concrete Filled-steel Tube Columns Reinforced with Steel Fibers

被引:7
|
作者
Naji, A. J. [1 ,2 ]
Al-Jelawy, H. M. [1 ]
Hassoon, A. [3 ]
Al-Rumaithi, A. [4 ]
机构
[1] Univ Al Qadisiyah, Rd & Transport Engn Dept, Diwaniyah, Iraq
[2] RUDN Univ, Civil Engn Dept, Peoples Friendship Univ Russia, Moscow, Russia
[3] Univ Al Qadisiyah, Civil Engn Dept, Diwaniyah, Iraq
[4] Univ Baghdad, Dept Civil Engn, Baghdad, Iraq
来源
INTERNATIONAL JOURNAL OF ENGINEERING | 2022年 / 35卷 / 09期
关键词
Concrete; Steel tube; Composite elements; Steel fibers; Ductility; Columns; PERFORMANCE;
D O I
10.5829/ije.2022.35.09c.02
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Concrete filled steel tube (CFST) columns are being popular in civil engineering due to their superior structural characteristics. This paper investigates enhancement in axial behavior of CFST columns by adding steel fibers to plain concrete that infill steel tubes. Four specimens were prepared: two square columns (100*100 mm) and two circular columns (100 mm in diameter). All columns were 60 cm in length. Plain concrete mix and concrete reinforced with steel fibers were used to infill steel tube columns. Ultimate axial load capacity, ductility and failure mode are discussed in this study. The results showed that the ultimate axial load capacity of CFST columns reinforced with steel fibers increased by 28% and 20 % for circular and square columns, respectively. Also, the circular CFST columns exhibited better ductility than the square CFST columns due to better concrete confinement. Circular and square CFST columns with steel fibers showed improved ductility by 16.3% and 12%, respectively. The failure mode of the square CFST columns were local buckling which occurred near the end of columns, while, for the circular CFST columns, local buckling occurred near the mid-height. Also, the study involved sectional analysis that captured the behavior of CFST columns very well. The sectional analysis showed that increasing steel fiber content to 2% increased the axial load capacity by 51 and 38% for circular and square CFST columns, respectively. Furthermore, sectional analysis showed that doubling section size increased axial load capacity by approximately 4 and 5 times for circular and square columns, respectively.
引用
下载
收藏
页码:1682 / 1689
页数:8
相关论文
共 50 条
  • [41] Experimental study on axial compression behaviour of steel reinforced concrete-filled steel tube (SRCFST) columns enhanced by steel rings and CFRP
    Lv, Leyang
    Wang, Jun
    Xie, Zhiyu
    STRUCTURES, 2024, 61
  • [42] The interaction of steel tube and concrete core in concrete-filled steel tube columns
    Starossek, U.
    Falah, N.
    TUBULAR STRUCTURES XII, 2009, : 75 - +
  • [43] Shear response of steel fiber reinforced recycled concrete-filled steel tube columns
    Liu, Zhenzhen
    Lu, Yiyan
    Li, Shan
    Liao, Jiancong
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (12) : 2684 - 2704
  • [44] Axial compression behavior of hybrid fiber reinforced concrete filled steel tube stub column
    Lu, Yiyan
    Liu, Zhenzhen
    Li, Shan
    Hu, Jiyue
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 174 : 96 - 107
  • [45] Finite Element Modelling of Concrete-Filled Steel Tube Reinforced Concrete stub Columns under Axial Compression
    Wang, Zhi-Bin
    Liu, Li-Ying
    ADVANCES IN CIVIL STRUCTURES, PTS 1 AND 2, 2013, 351-352 : 138 - 142
  • [46] A unified formulation for axial compression of steel tube-confined concrete and concrete-filled steel tube stub columns
    Li, Wentao
    Zha, Xiaoxiong
    Wang, Haiyang
    STRUCTURES, 2023, 58
  • [47] Axial load behavior of stiffened concrete-filled steel columns
    Huang, CS
    Yeh, YK
    Liu, GY
    Hu, HT
    Tsai, KC
    Weng, YT
    Wang, SH
    Wu, MH
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2002, 128 (09): : 1222 - 1230
  • [48] Axial Compression Experiment and Bearing Capacity Calculation of Thin-walled Concrete Filled-steel Tube Columns with Different Restraint Forms
    Wang Z.
    Feng Y.
    Lu J.
    Li X.
    Tian J.
    Gongcheng Kexue Yu Jishu/Advanced Engineering Sciences, 2021, 53 (01): : 18 - 28
  • [49] Axial compression behavior of steel tube reinforced concrete column
    He, Fuyun
    Li, Cong
    Chen, Baochun
    Briseghella, Bruno
    Xue, Junqing
    ENGINEERING STRUCTURES, 2024, 303
  • [50] Performance of concrete filled steel tube reinforced concrete columns subjected to cyclic bending
    Han, Lin-Hai
    Liao, Fei-Yu
    Tao, Zhong
    Hong, Zhe
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (8-9) : 1607 - 1616