Axial Behavior of Concrete Filled-steel Tube Columns Reinforced with Steel Fibers

被引:7
|
作者
Naji, A. J. [1 ,2 ]
Al-Jelawy, H. M. [1 ]
Hassoon, A. [3 ]
Al-Rumaithi, A. [4 ]
机构
[1] Univ Al Qadisiyah, Rd & Transport Engn Dept, Diwaniyah, Iraq
[2] RUDN Univ, Civil Engn Dept, Peoples Friendship Univ Russia, Moscow, Russia
[3] Univ Al Qadisiyah, Civil Engn Dept, Diwaniyah, Iraq
[4] Univ Baghdad, Dept Civil Engn, Baghdad, Iraq
来源
INTERNATIONAL JOURNAL OF ENGINEERING | 2022年 / 35卷 / 09期
关键词
Concrete; Steel tube; Composite elements; Steel fibers; Ductility; Columns; PERFORMANCE;
D O I
10.5829/ije.2022.35.09c.02
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Concrete filled steel tube (CFST) columns are being popular in civil engineering due to their superior structural characteristics. This paper investigates enhancement in axial behavior of CFST columns by adding steel fibers to plain concrete that infill steel tubes. Four specimens were prepared: two square columns (100*100 mm) and two circular columns (100 mm in diameter). All columns were 60 cm in length. Plain concrete mix and concrete reinforced with steel fibers were used to infill steel tube columns. Ultimate axial load capacity, ductility and failure mode are discussed in this study. The results showed that the ultimate axial load capacity of CFST columns reinforced with steel fibers increased by 28% and 20 % for circular and square columns, respectively. Also, the circular CFST columns exhibited better ductility than the square CFST columns due to better concrete confinement. Circular and square CFST columns with steel fibers showed improved ductility by 16.3% and 12%, respectively. The failure mode of the square CFST columns were local buckling which occurred near the end of columns, while, for the circular CFST columns, local buckling occurred near the mid-height. Also, the study involved sectional analysis that captured the behavior of CFST columns very well. The sectional analysis showed that increasing steel fiber content to 2% increased the axial load capacity by 51 and 38% for circular and square CFST columns, respectively. Furthermore, sectional analysis showed that doubling section size increased axial load capacity by approximately 4 and 5 times for circular and square columns, respectively.
引用
下载
收藏
页码:1682 / 1689
页数:8
相关论文
共 50 条
  • [31] Study on axial compression behavior of built-in lattice concrete-filled steel tube cruciform steel reinforced concrete short columns after fire
    Chen H.
    Cao W.
    Liu H.
    Liu W.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 : 229 - 238
  • [32] Bearing capacity of composite columns reinforced by concrete filled steel tube
    韦建刚
    ZHU Pu
    CHEN Bao-chun
    Journal of Chongqing University(English Edition), 2013, 12 (01) : 27 - 34
  • [33] Creep behavior of reinforced concrete-filled steel tubular columns under axial compression
    Zhang, Ni
    Zheng, Chenyang
    Sun, Qingwei
    PLOS ONE, 2021, 16 (09):
  • [34] Axial capacity of steel tube-reinforced concrete stub columns
    Hong, Huan-Peng
    Yuan, Huang
    Deng, Lu
    Bai, Yu
    ENGINEERING STRUCTURES, 2019, 183 : 523 - 532
  • [35] Mechanical behavior of concrete filled circular steel tubular stub columns with axial pre-stress in steel tube
    School of Civil Engineering and Architecture, Central South University, Changsha 410075, Hunan, China
    J. Traffic Transp. Eng., 2006, 3 (57-61):
  • [36] Axial compressive behavior of circular concrete-filled steel tube stub columns with steel slag coarse aggregate
    Lu, Linhan
    Zhang, Tianhe
    Liang, Tao
    Ren, Qingxin
    STRUCTURES, 2023, 51 : 1893 - 1905
  • [37] Behavior of steel-reinforced concrete-filled square steel tubular stub columns under axial loading
    Ding, Fa-xing
    Zhang, Tao
    Liu, Xue-mei
    Lu, Zhao-Hui
    Guo, Qiang
    Jiang, Guo-shuai
    THIN-WALLED STRUCTURES, 2017, 119 : 737 - 748
  • [38] Seismic behavior of steel tube reinforced concrete bridge columns
    Tian, Tian
    Qiu, Wen-liang
    Zhang, Zhe
    STEEL AND COMPOSITE STRUCTURES, 2018, 28 (01): : 63 - 71
  • [39] Axial behavior of ultra-high performance steel fiber reinforced concrete filled circular steel tubular columns
    Cai, Heng
    Zeng, Yanqin
    Xu, Lihua
    Liu, Jungang
    STRUCTURES, 2024, 68
  • [40] Axial behaviour of slender concrete-filled steel tube square columns strengthened with square concrete-filled steel tube jackets
    Zhu, Tao
    Liang, Hongjun
    Lu, Yiyan
    Li, Weijie
    Zhang, Hong
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (06) : 1074 - 1086