Axial Behavior of Concrete Filled-steel Tube Columns Reinforced with Steel Fibers

被引:7
|
作者
Naji, A. J. [1 ,2 ]
Al-Jelawy, H. M. [1 ]
Hassoon, A. [3 ]
Al-Rumaithi, A. [4 ]
机构
[1] Univ Al Qadisiyah, Rd & Transport Engn Dept, Diwaniyah, Iraq
[2] RUDN Univ, Civil Engn Dept, Peoples Friendship Univ Russia, Moscow, Russia
[3] Univ Al Qadisiyah, Civil Engn Dept, Diwaniyah, Iraq
[4] Univ Baghdad, Dept Civil Engn, Baghdad, Iraq
来源
INTERNATIONAL JOURNAL OF ENGINEERING | 2022年 / 35卷 / 09期
关键词
Concrete; Steel tube; Composite elements; Steel fibers; Ductility; Columns; PERFORMANCE;
D O I
10.5829/ije.2022.35.09c.02
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Concrete filled steel tube (CFST) columns are being popular in civil engineering due to their superior structural characteristics. This paper investigates enhancement in axial behavior of CFST columns by adding steel fibers to plain concrete that infill steel tubes. Four specimens were prepared: two square columns (100*100 mm) and two circular columns (100 mm in diameter). All columns were 60 cm in length. Plain concrete mix and concrete reinforced with steel fibers were used to infill steel tube columns. Ultimate axial load capacity, ductility and failure mode are discussed in this study. The results showed that the ultimate axial load capacity of CFST columns reinforced with steel fibers increased by 28% and 20 % for circular and square columns, respectively. Also, the circular CFST columns exhibited better ductility than the square CFST columns due to better concrete confinement. Circular and square CFST columns with steel fibers showed improved ductility by 16.3% and 12%, respectively. The failure mode of the square CFST columns were local buckling which occurred near the end of columns, while, for the circular CFST columns, local buckling occurred near the mid-height. Also, the study involved sectional analysis that captured the behavior of CFST columns very well. The sectional analysis showed that increasing steel fiber content to 2% increased the axial load capacity by 51 and 38% for circular and square CFST columns, respectively. Furthermore, sectional analysis showed that doubling section size increased axial load capacity by approximately 4 and 5 times for circular and square columns, respectively.
引用
收藏
页码:1682 / 1689
页数:8
相关论文
共 50 条
  • [21] Axial Compression Behavior of Rectangular Concrete-Filled Steel Tube Columns Reinforced by Built-In Profiled Stirrup
    Kang, Lan
    Chen, Xuan
    Hong, Shutao
    [J]. Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2024, 52 (05): : 101 - 113
  • [22] Finite element analysis and axial bearing capacity of steel reinforced recycled concrete filled square steel tube columns
    Dong, Jing
    Ma, Hui
    Zou, Changming
    Liu, Yunhe
    Huang, Chen
    [J]. STRUCTURAL ENGINEERING AND MECHANICS, 2019, 72 (01) : 805 - 822
  • [23] Axial compressive behavior of square steel tubular columns filled with steel stirrups reinforced recycled lump concrete
    Zang, Jian-Bo
    Wu, Bo
    [J]. STRUCTURES, 2022, 36 : 735 - 751
  • [24] Axial compressive behavior of reinforced concrete-filled stainless steel tube (RCFSST) stub columns: Experimental research
    Qiao, Qiyun
    Li, Jiafeng
    Mou, Ben
    Cao, Wanlin
    [J]. Journal of Building Engineering, 2021, 44
  • [25] Axial capacity of circular concrete-filled steel tube columns
    Mimoune, Mostefa
    Mimoune, Fatima Z.
    Youcef, Mourad Ait
    [J]. WORLD JOURNAL OF ENGINEERING, 2011, 8 (03) : 237 - 244
  • [26] Axial behaviour of concrete filled steel tube stub columns: a review
    Guler, S.
    Korkut, F.
    Yaltay, N.
    Yavuz, D.
    [J]. PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 359 - 363
  • [27] Deformation behavior of steel tube-confined concrete-filled steel tube columns under sustained axial compression
    Li, Yanhua
    Zhang, Sumei
    Wang, Yan
    Wang, Yuyin
    [J]. Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2023, 55 (09): : 101 - 110
  • [28] Behavior of steel tube columns filled with steel-fiber-reinforced self-stressing recycled aggregate concrete under axial compression
    Liu, Zhenzhen
    Lu, Yiyan
    Li, Shan
    Yi, Si
    [J]. THIN-WALLED STRUCTURES, 2020, 149
  • [29] Strength prediction of corrosion reinforced concrete columns strengthened with concrete filled steel tube under axial compression
    Liang, Hongjun
    Jiang, Yanju
    Lu, Yiyan
    Hu, Jiyue
    [J]. STEEL AND COMPOSITE STRUCTURES, 2020, 37 (04): : 481 - 492
  • [30] Behavior of concrete-filled steel tube beam columns
    Inai, E
    Mukai, A
    Kai, M
    Tokinoya, H
    Fukumoto, T
    Mori, K
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2004, 130 (02): : 189 - 202