Coronary calcification at electron-beam CT: Effect of section thickness on calcium scoring in vitro and in vivo

被引:38
|
作者
Vliegenthart, R
Song, B
Hofman, A
Witteman, JCM
Oudkerk, M
机构
[1] Univ Groningen, Univ Groningen Hosp, Dept Radiol, NL-9713 GZ Groningen, Netherlands
[2] Erasmus MC, Daniel Den Hoed Clin, Dept Epidemiol, Rotterdam, Netherlands
[3] Erasmus MC, Daniel Den Hoed Clin, Dept Biostat, Rotterdam, Netherlands
[4] 1 Univ Hosp, Dept Radiol, Chengdu, Peoples R China
关键词
coronary vessels; calcification; CT;
D O I
10.1148/radiol.2292021305
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the accuracy of electron-beam computed tomography (CT) with 3.0- and 1.5-mm section thickness for calcium quantification and the prevalence of coronary calcifications with each. MATERIALS AND METHODS: Electron-beam CT images were acquired with nonoverlapping 1.5- and 3.0-mm section thickness. Scans were obtained in an anthropomorphic thorax phantom with calcium cylinders of different sizes and densities, as well as in 1,302 study participants. A calcified lesion was defined as a minimum of 2 pixels (area, 0.52 mm(2)) with a minimum attenuation of 130 HU. The calcified lesions were quantified by means of a volumetric method with isotropic interpolation. From the phantom scans mean volume scores, SDs, and measurement variations were calculated. From the participant scans, median volume scores and interquartile ranges were calculated. Participants were classified in categories based on cutoff levels for volume score quartiles for the 1.5-mm scans. An intraclass correlation coefficient (K value) was calculated as a measure of correlation between categories. RESULTS: In the phantom, deviations of calculated volumes from the true cylinder volumes and measurement variations were generally higher for the 3.0-mm protocol than for the 1.5-mm protocol. In the participants, the median volume score was 100 mm(3) (interquartile range, 11-409 mm(3)) for the 3.0-mm protocol and 144 mm(3) (interquartile range, 35-513 mm(3)) for the 1.5-mm protocol. Agreement between classifications of volume scores for the 1.5- and 3.0-mm scans was good (K = 0.62, P <.001). Compared with the quartile classification for the 1.5-mm scan, however, classifications for 370 (28%) participants were put in a different category with the 3.0-mm protocol. CONCLUSION: In a phantom, electron-beam CT scans with 3.0-mm section thickness yield less accurate estimates of calcified volume than do 1.5-mm scans. Electron-beam CT protocols with thinner sections considerably affect classification of individuals on the basis of the amount of coronary calcification depicted. (C) RSNA, 2003.
引用
收藏
页码:520 / 525
页数:6
相关论文
共 50 条
  • [31] Correlation between calcification of the carotid arteries documented by ultrasound, coronary calcifications in electron-beam CT, and angiographic coronary artery disease
    Moshage, W
    Achenbach, S
    Schwarz, T
    Brandt-Pohlmann, M
    Daniel, WG
    [J]. EUROPEAN HEART JOURNAL, 2000, 21 : 569 - 569
  • [32] Coronary artery calcification measured at electron-beam CT: Agreement in dual scan runs and change over time
    Bielak, LF
    Sheedy, PF
    Peyser, PA
    [J]. RADIOLOGY, 2001, 218 (01) : 224 - 229
  • [33] Pictorial essay - Electron beam CT of the coronary arteries: Cross-sectional anatomy for calcium scoring
    Sevrukov, A
    Jelnin, V
    Kondos, GT
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (06) : 1437 - 1445
  • [34] Radiation dose in coronary calcium scoring: Comparison of multi-slice and electron beam CT scanners
    Jerjian, K
    Brant-Zawadzki, MN
    [J]. RADIOLOGY, 2001, 221 : 365 - 365
  • [35] Assessment of coronary artery stent patency by electron-beam CT
    Knollmann, FD
    Möller, J
    Gebert, A
    Bethge, C
    Felix, R
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (08) : 1341 - 1347
  • [36] Electron-beam CT in the noninvasive assessment of coronary stent patency
    Pump, H
    Moehlenkamp, S
    Sehnert, C
    Schimpf, SS
    Erbel, R
    Seibel, RMM
    Groenemeyer, DHW
    [J]. ACADEMIC RADIOLOGY, 1998, 5 (12) : 858 - 862
  • [37] Assessment of coronary artery stent patency by electron-beam CT
    Friedrich D. Knollmann
    Jörg Möller
    Axel Gebert
    Christian Bethge
    Roland Felix
    [J]. European Radiology, 2004, 14 : 1341 - 1347
  • [38] Preview method for electron-beam CT scanning of the coronary arteries
    Bakhsheshi, H
    Mao, SS
    Budoff, MJ
    Bin, L
    Brundage, BH
    [J]. ACADEMIC RADIOLOGY, 2000, 7 (08) : 620 - 626
  • [39] Coronary artery anomalies with a shunt: Evaluation with electron-beam CT
    Yoshimura, N
    Hamada, S
    Takamiya, M
    Kuribayashi, S
    Kimura, K
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (05) : 682 - 686
  • [40] Coronary arterial stent patency:: Assessment with electron-beam CT
    Pump, H
    Möhlenkamp, S
    Sehnert, CA
    Schimpf, SS
    Schmidt, A
    Erbel, R
    Grönemeyer, DHW
    Seibel, RMM
    [J]. RADIOLOGY, 2000, 214 (02) : 447 - 452