Coronary calcification at electron-beam CT: Effect of section thickness on calcium scoring in vitro and in vivo

被引:38
|
作者
Vliegenthart, R
Song, B
Hofman, A
Witteman, JCM
Oudkerk, M
机构
[1] Univ Groningen, Univ Groningen Hosp, Dept Radiol, NL-9713 GZ Groningen, Netherlands
[2] Erasmus MC, Daniel Den Hoed Clin, Dept Epidemiol, Rotterdam, Netherlands
[3] Erasmus MC, Daniel Den Hoed Clin, Dept Biostat, Rotterdam, Netherlands
[4] 1 Univ Hosp, Dept Radiol, Chengdu, Peoples R China
关键词
coronary vessels; calcification; CT;
D O I
10.1148/radiol.2292021305
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the accuracy of electron-beam computed tomography (CT) with 3.0- and 1.5-mm section thickness for calcium quantification and the prevalence of coronary calcifications with each. MATERIALS AND METHODS: Electron-beam CT images were acquired with nonoverlapping 1.5- and 3.0-mm section thickness. Scans were obtained in an anthropomorphic thorax phantom with calcium cylinders of different sizes and densities, as well as in 1,302 study participants. A calcified lesion was defined as a minimum of 2 pixels (area, 0.52 mm(2)) with a minimum attenuation of 130 HU. The calcified lesions were quantified by means of a volumetric method with isotropic interpolation. From the phantom scans mean volume scores, SDs, and measurement variations were calculated. From the participant scans, median volume scores and interquartile ranges were calculated. Participants were classified in categories based on cutoff levels for volume score quartiles for the 1.5-mm scans. An intraclass correlation coefficient (K value) was calculated as a measure of correlation between categories. RESULTS: In the phantom, deviations of calculated volumes from the true cylinder volumes and measurement variations were generally higher for the 3.0-mm protocol than for the 1.5-mm protocol. In the participants, the median volume score was 100 mm(3) (interquartile range, 11-409 mm(3)) for the 3.0-mm protocol and 144 mm(3) (interquartile range, 35-513 mm(3)) for the 1.5-mm protocol. Agreement between classifications of volume scores for the 1.5- and 3.0-mm scans was good (K = 0.62, P <.001). Compared with the quartile classification for the 1.5-mm scan, however, classifications for 370 (28%) participants were put in a different category with the 3.0-mm protocol. CONCLUSION: In a phantom, electron-beam CT scans with 3.0-mm section thickness yield less accurate estimates of calcified volume than do 1.5-mm scans. Electron-beam CT protocols with thinner sections considerably affect classification of individuals on the basis of the amount of coronary calcification depicted. (C) RSNA, 2003.
引用
收藏
页码:520 / 525
页数:6
相关论文
共 50 条
  • [21] Statins, electron-beam CT, and aortic-valve calcification
    Melina, G
    Rubens, MB
    Yacoub, MH
    LANCET, 2002, 360 (9328): : 258 - 258
  • [22] Coronary calcium scoring with electron beam and multidetector CT: Comparing interscan variation using two scoring algorithms
    Bracha, AS
    Yoon, HC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 66 - 66
  • [23] Coronary calcification detected by electron-beam computed tomography and myocardial infarction - The Rotterdam Coronary Calcification Study
    Vliegenthart, R
    Oudkerk, M
    Song, B
    van der Kuip, DAM
    Hofman, A
    Witteman, JCM
    EUROPEAN HEART JOURNAL, 2002, 23 (20) : 1596 - 1603
  • [24] Comparison of two different software systems for electron-beam CT-derived quantification of coronary calcification
    Adamzik, M
    Schmermund, A
    Reed, JE
    Adamzik, S
    Behrenbeck, T
    Sheedy, PF
    INVESTIGATIVE RADIOLOGY, 1999, 34 (12) : 767 - 773
  • [25] Natural history and topographic pattern of progression of coronary calcification in symptomatic patients -: An electron-beam CT study
    Schmermund, A
    Baumgart, D
    Möhlenkamp, S
    Kriener, P
    Pump, H
    Grönemeyer, D
    Seibel, R
    Erbel, R
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2001, 21 (03) : 421 - 426
  • [26] AN ELECTRON-BEAM CT APPROACH FOR TRANSVENOUS CORONARY ARTERIOGRAPHY
    THOMAS, PJ
    MCCOLLOUGH, CH
    RITMAN, EL
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (03) : 383 - 389
  • [27] Calcium scoring of the coronary artery by electron beam CT: How to apply an individual attenuation threshold
    Raggi, P
    Callister, TQ
    Cooil, B
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (02) : 497 - 502
  • [28] SMALL LESIONS IN THE HEART IDENTIFIED AT ELECTRON-BEAM CT - CALCIFICATION OR NOISE
    BIELAK, LF
    KAUFMANN, RB
    MOLL, PP
    MCCOLLOUGH, CH
    SCHWARTZ, RS
    SHEEDY, PF
    RADIOLOGY, 1994, 192 (03) : 631 - 636
  • [29] Coronary artery calcium quantification at multi-detector row helical CT versus electron-beam CT
    Stanford, W
    Thompson, BH
    Burns, TL
    Heery, SD
    Burr, MC
    RADIOLOGY, 2004, 230 (02) : 397 - 402
  • [30] Association between progression of aortic valve calcification and coronary calcification: A study of electron-beam tomography
    Takasu, J
    Shavelle, D
    Budoff, MJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (2A): : 86E - 86E