Performance of a New Test Strip for FreeStyle Blood Glucose Monitoring Systems

被引:8
|
作者
Lock, John Paul [2 ]
Brazg, Ronald [3 ]
Bernstein, Robert M. [4 ]
Taylor, Elizabeth [5 ]
Patel, Mona [1 ]
Ward, Jeanne [1 ]
Alva, Shridhara [1 ]
Chen, Ting [1 ]
Welsh, Zoe [1 ]
Amor, Walter [1 ]
Bhogal, Claire [1 ]
Ng, Ronald [1 ]
机构
[1] Abbott Diabet Care, Alameda, CA 94502 USA
[2] Internal Med & Endocrinol, Worcester, MA USA
[3] Rainier Clin Res, Renton, WA USA
[4] Reg Endocrinol Associates, Santa Fe, NM USA
[5] Mass Res, Waltham, MA USA
关键词
D O I
10.1089/dia.2010.0116
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A new strip, designed to enhance the ease of use and minimize interference of non-glucose sugars, has been developed to replace the current FreeStyle (R) (Abbott Diabetes Care, Alameda, CA) blood glucose test strip. We evaluated the performance of this new strip. Methods: Laboratory evaluation included precision, linearity, dynamic range, effects of operating temperature, humidity, altitude, hematocrit, interferents, and blood reapplication. System accuracy, lay user performance, and ease of use for finger capillary blood testing and accuracy for venous blood testing were evaluated at clinics. Lay users also compared the speed and ease of use between the new strip and the current FreeStyle strip. Results: For glucose concentrations <75 mg/dL, 73%, 100%, and 100% of the individual capillary blood glucose results obtained by lay users fell within +/- 5, 10, and 15 mg/dL, respectively, of the reference. For glucose concentrations >= 75 mg/dL, 68%, 95%, 99%, and 99% of the lay user results fell within +/- 5%, 10%, 15%, and 20%, respectively, of the reference. Comparable accuracy was obtained in the venous blood study. Lay users found the new test strip easy to use and faster and easier to use than the current FreeStyle strip. The new strip maintained accuracy under various challenging conditions, including high concentrations of various interferents, sample reapplication up to 60 s, and extremes in hematocrit, altitude, and operating temperature and humidity. Conclusions: Our results demonstrated excellent accuracy of the new FreeStyle test strip and validated the improvements in minimizing interference and enhancing ease of use.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [31] A NEW VISUAL BLOOD-GLUCOSE STRIP
    CLARK, AJL
    BUNDOCK, J
    NEWALL, RG
    KEEN, H
    DIABETOLOGIA, 1982, 23 (05) : 466 - 466
  • [32] THE ONETOUCH SELECT® PLUS BLOOD GLUCOSE MONITORING SYSTEM: TEST STRIP PERFORMANCE DEMONSTRATES INSENSITIVITY TO HAEMATOCRIT AND MEETS ISO 15197:2013
    Smith, A.
    Setford, S.
    McColl, D.
    Grady, M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 : A92 - A92
  • [33] Performance of strip-based glucose meters for monitoring glucose levels
    Claerhout, H.
    De Prins, M.
    Mesotten, D.
    Van den Berghe, G.
    Mathieu, C.
    Van Eldere, J.
    Vanstapel, F.
    ACTA CLINICA BELGICA, 2015, 70 : S5 - S6
  • [34] Accuracy Performance of Six Self-Monitoring Blood Glucose Systems
    Kum, Maxwell C.
    Manesh, Kalayil Manian
    Wang, Steven Chialin
    Bailey, Timothy S.
    DIABETES, 2015, 64 : A238 - A239
  • [35] Clinical Performance of One Touch Verio Blood Glucose Monitoring Systems
    Setford, Steven J.
    Mackintosh, Stephen
    Phillips, Stuart
    Cameron, Hilary
    Miller, Lesley
    DIABETES, 2016, 65 : A231 - A231
  • [36] Self-monitoring blood glucose test strip use with diabetes medicines in people with types 1 and 2 diabetes in New Zealand
    Metcalfe, Scott
    Moodie, Peter
    Norris, Hew
    Rasiah, Dilky
    NEW ZEALAND MEDICAL JOURNAL, 2014, 127 (1406) : 48 - 62
  • [37] Measurement of glucose concentrations of potato extract using a blood glucose test strip
    Misener, GC
    Gerber, WA
    Tai, GCC
    Embleton, EJ
    CANADIAN AGRICULTURAL ENGINEERING, 1996, 38 (01): : 59 - 62
  • [38] Comparison of the FreeStyle and the OneTouch Ultra Blood Glucose Monitoring System using capillary blood from the forearm
    White, JR
    Baco, F
    Malone, J
    DIABETES, 2002, 51 : A127 - A127
  • [39] Waste of test strips compared among four blood glucose monitoring systems
    Ng, R.
    Schwartz, S.
    Taylor, E.
    DIABETOLOGIA, 2009, 52 : S368 - S368
  • [40] FLASH GLUCOSE MONITORING SYSTEM (FREESTYLE): NEW METHOD OF CONTROL IN DIABETIC CHILDREN
    Freijo, Concepcion
    Bertholt, Laura
    Naranjo, Cristina
    HORMONE RESEARCH IN PAEDIATRICS, 2017, 88 : 236 - 237