Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation

被引:20
|
作者
Abduo, Jaafar [1 ]
Palamara, Joseph E. A. [2 ]
机构
[1] Univ Melbourne, Melbourne Dent Sch, Prosthodont Dept, Clin Dent Implants, 720 Swanston St, Melbourne, Vic 3010, Australia
[2] Univ Melbourne, Melbourne Dent Sch, Restorat Sect, 720 Swanston St, Melbourne, Vic 3010, Australia
关键词
Implant impression; Precision; Scanning; Splinted; Trueness; TECHNOLOGY; ABUTMENT;
D O I
10.1186/s40729-021-00355-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Accurate implant impression is an essential requirement for the fabrication of implant prosthesis. This in vitro study evaluated the accuracy of digital impressions by intraoral scanner (IOS) systems in comparison to conventional impressions for recording the position of 2 parallel implants and 2 divergent implants. Materials and methods In vitro 3-unit prosthesis master models with 2 tissue level implants were fabricated; one model had parallel implants, and the other model had one 15 degrees tilted implant. The conventional open-tray impressions were obtained with non-splinted (NSP) and splinted (SP) impression copings. Trios 4 (TS), Medit i500 (MT), and True Definition (TD) were used to make digital impressions with scan bodies. A total of 10 impressions were obtained with every technique. The virtual test images of the conventional and digital impressions were converted to 2 virtual implant images. For each group, trueness, precision, inter-implant distance deviation, and angle deviation were measured. Results There was a general tendency for digital impressions to provide a more accurate outcome for trueness, precision, and angle deviation. The 2 conventional impressions showed similar accuracy, except for the angle deviation, where the NSP was significantly inferior than SP (p < 0.01) for the divergent implants model. The TD was generally the least accurate among all the IOS systems, especially for the inter-implant distance deviation (p < 0.05). Conclusions Within the limitations of the laboratory set-up of the present study and the limited clinical resemblance, the digital impressions appeared to have sufficient accuracy for 2 implants and were least affected by the presence of angle between implants. The most inferior outcome was observed for the NSP technique.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Trueness of digital implant impressions based on implant angulation and scan body materials
    Lee, Jae-Hyun
    Bae, Jae-Hwi
    Lee, Su Young
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [32] Effects of Implant Angulation and Impression Coping Type on the Dimensional Accuracy of Impressions
    Shim, Ji Suk
    Ryu, Jae Jun
    Shin, Sang Wan
    Lee, Jeong Yol
    IMPLANT DENTISTRY, 2015, 24 (06) : 726 - 729
  • [33] Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study
    Gedrimiene, Agne
    Adaskevicius, Rimas
    Rutkunas, Vygandas
    JOURNAL OF ADVANCED PROSTHODONTICS, 2019, 11 (05): : 271 - 279
  • [34] Trueness of Extraoral Digital Impressions for Full-Arch Implant Impressions-In Vitro Study
    Sampaio-Fernandes, Manuel Antonio
    Pinto, Ricardo
    Almeida, Paulo Rocha
    Sampaio-Fernandes, Maria Margarida
    Marques, Duarte
    Figueiral, Maria Helena
    MATERIALS, 2024, 17 (12)
  • [35] Conventional and Digital Impressions for Fabrication of Complete Implant-Supported Bars: A Comparative In Vitro Study
    Vieira, Samanta N. V.
    Lourenco, Matheus F.
    Pereira, Rodrigo C.
    Franca, Esdras C.
    Vilaca, Enio L.
    Silveira, Rodrigo R.
    Silva, Guilherme C.
    MATERIALS, 2023, 16 (11)
  • [36] In Vitro Comparative Analysis of Digital Versus Conventional Impressions in Fixed Prosthodontics
    Raja, Ramesh S.
    Dutta, Arjita
    Jain, Saket Kumar
    Dewan, Harisha
    Thomas, Vishnu
    Jose, Ajimol Theresa
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2700 - S2702
  • [37] Could various angulated implant depths affect the positional accuracy of digital impressions? An in vitro study
    Taghva, Masumeh
    Mosaddad, Seyed Ali
    Ansarifard, Elham
    Sadeghi, Mohsen
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (08): : 791 - 800
  • [38] The effect of the abutment occlusal convergence angles on the accuracy of digital and conventional impressions
    Jivanescu, Anca
    Rotar, Raul
    Gavilovici, Andrei
    Pricop, Cristiana
    Goguta, Luciana
    SEVENTH INTERNATIONAL CONFERENCE ON LASERS IN MEDICINE, 2018, 10831
  • [39] Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations
    Bi, Chuang
    Wang, Xingyu
    Tian, Fangfang
    Qu, Zhe
    Zhao, Jiaming
    JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (04): : 236 - 249
  • [40] Effect of Implant Divergence on the Accuracy of Definitive Casts Created from Traditional and Digital Implant-Level Impressions: An In Vitro Comparative Study
    Lin, Wei-Shao
    Harris, Bryan T.
    Elathamna, Eiad N.
    Abdel-Azim, Tamer
    Morton, Dean
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (01) : 102 - 109