Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation

被引:19
|
作者
Abduo, Jaafar [1 ]
Palamara, Joseph E. A. [2 ]
机构
[1] Univ Melbourne, Melbourne Dent Sch, Prosthodont Dept, Clin Dent Implants, 720 Swanston St, Melbourne, Vic 3010, Australia
[2] Univ Melbourne, Melbourne Dent Sch, Restorat Sect, 720 Swanston St, Melbourne, Vic 3010, Australia
关键词
Implant impression; Precision; Scanning; Splinted; Trueness; TECHNOLOGY; ABUTMENT;
D O I
10.1186/s40729-021-00355-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Accurate implant impression is an essential requirement for the fabrication of implant prosthesis. This in vitro study evaluated the accuracy of digital impressions by intraoral scanner (IOS) systems in comparison to conventional impressions for recording the position of 2 parallel implants and 2 divergent implants. Materials and methods In vitro 3-unit prosthesis master models with 2 tissue level implants were fabricated; one model had parallel implants, and the other model had one 15 degrees tilted implant. The conventional open-tray impressions were obtained with non-splinted (NSP) and splinted (SP) impression copings. Trios 4 (TS), Medit i500 (MT), and True Definition (TD) were used to make digital impressions with scan bodies. A total of 10 impressions were obtained with every technique. The virtual test images of the conventional and digital impressions were converted to 2 virtual implant images. For each group, trueness, precision, inter-implant distance deviation, and angle deviation were measured. Results There was a general tendency for digital impressions to provide a more accurate outcome for trueness, precision, and angle deviation. The 2 conventional impressions showed similar accuracy, except for the angle deviation, where the NSP was significantly inferior than SP (p < 0.01) for the divergent implants model. The TD was generally the least accurate among all the IOS systems, especially for the inter-implant distance deviation (p < 0.05). Conclusions Within the limitations of the laboratory set-up of the present study and the limited clinical resemblance, the digital impressions appeared to have sufficient accuracy for 2 implants and were least affected by the presence of angle between implants. The most inferior outcome was observed for the NSP technique.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] The Accuracy of Digital Impressions versus Conventional Impressions in Neonates with Cleft Lip and/or Palate: A Laboratory-Based Study
    Unnikrishnan, Jyotsna
    Bakr, Mahmoud
    Love, Robert
    Idris, Ghassan
    CHILDREN-BASEL, 2024, 11 (07):
  • [22] In Vitro Accuracy of Digital and Conventional Impressions for Full-Arch Implant-Supported Prostheses
    D'haese, Rani
    Vrombaut, Tom
    Roeykens, Herman
    Vandeweghe, Stefan
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [23] In vitro accuracy of digital and conventional impressions in the partially edentulous maxilla
    Waldecker, Moritz
    Rues, Stefan
    Awounvo Awounvo, Junior Sinclair
    Rammelsberg, Peter
    Boemicke, Wolfgang
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (11) : 6491 - 6502
  • [24] In vitro accuracy of digital and conventional impressions in the partially edentulous maxilla
    Moritz Waldecker
    Stefan Rues
    Junior Sinclair Awounvo Awounvo
    Peter Rammelsberg
    Wolfgang Bömicke
    Clinical Oral Investigations, 2022, 26 : 6491 - 6502
  • [25] Digital Impressions Versus Conventional Impressions in Prosthodontics: A Systematic Review
    Ahmed, Suhael
    Hawsah, Abeer
    Rustom, Randa
    Alamri, Abeer
    Althomairy, Sameer
    Alenezi, Maha
    Shaker, Sarah
    Alrawsaa, Faisal
    Althumairy, Ahmed
    Alteraigi, Abdullah
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [26] Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations
    Onoral, Ozay
    Kurtulmus-Yilmaz, Sevcan
    Toksoy, Dilem
    Ozan, Oguz
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (06): : 290 - 301
  • [27] Influence of the Angulation and Insertion Depth of Implants on the 3D Trueness of Conventional and Digital Impressions
    Onoral, Ozay
    Kurtulmus-Yilmaz, Sevcan
    Keskin, Aynil
    Ozan, Oguz
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (06) : 1186 - 1194
  • [28] Accuracy of intraoral photogrammetry versus direct digital implant impressions in the fully edentulous lower jaw: An in vitro study
    Brakoc, Jelena
    Todorovic, Ana
    Mangano, Francesco Guido
    Glisic, Mirko
    Scepanovic, Miodrag
    JOURNAL OF DENTISTRY, 2025, 156
  • [29] Trueness of digital implant impressions based on implant angulation and scan body materials
    Jae-Hyun Lee
    Jae-Hwi Bae
    Su Young Lee
    Scientific Reports, 11
  • [30] In vitro and in vivo accuracy of full-arch digital implant impressions
    Rutkunas, Vygandas
    Gedrimiene, Agne
    Akulauskas, Mykolas
    Fehmer, Vincent
    Sailer, Irena
    Jegelevicius, Darius
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (12) : 1444 - 1454