Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

被引:2
|
作者
Onoral, Ozay [1 ]
Kurtulmus-Yilmaz, Sevcan [1 ]
Toksoy, Dilem [1 ]
Ozan, Oguz [1 ]
机构
[1] Near East Univ, Fac Dent, Dept Prosthodont, Mersin 10, Nicosia, Cyprus, Turkiye
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2023年 / 15卷 / 06期
关键词
Angulated implants; Closed tray; Splinted open tray; Intraoral scanners; Scan path; COMPARATIVE IN-VITRO; MULTIPLE IMPLANTS; SUBGINGIVAL DEPTH; ACCURACY; PROSTHESES; PRECISION; SCANNERS; IMPACT;
D O I
10.4047/jap.2023.15.6.290
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P <= .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.
引用
收藏
页码:290 / 301
页数:12
相关论文
共 50 条
  • [1] Influence of the Angulation and Insertion Depth of Implants on the 3D Trueness of Conventional and Digital Impressions
    Onoral, Ozay
    Kurtulmus-Yilmaz, Sevcan
    Keskin, Aynil
    Ozan, Oguz
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (06) : 1186 - 1194
  • [2] Trueness of digital implant impressions based on implant angulation and scan body materials
    Jae-Hyun Lee
    Jae-Hwi Bae
    Su Young Lee
    Scientific Reports, 11
  • [3] Trueness of digital implant impressions based on implant angulation and scan body materials
    Lee, Jae-Hyun
    Bae, Jae-Hwi
    Lee, Su Young
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [4] Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation
    Abduo, Jaafar
    Palamara, Joseph E. A.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [5] Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation
    Jaafar Abduo
    Joseph E. A. Palamara
    International Journal of Implant Dentistry, 7
  • [6] Accuracy of Extraoral Digital Impressions with Multi-Unit Implants
    Sampaio-Fernandes, Manuel Antonio
    Pinto, Ricardo
    Almeida, Paulo Rocha
    Sampaio-Fernandes, Maria Margarida
    Marques, Duarte
    Figueiral, Maria Helena
    APPLIED SCIENCES-BASEL, 2023, 13 (15):
  • [7] Trueness and Precision Achieved With Conventional and Digital Implant Impressions: A Comparative Investigation of Stone Versus 3-D Printed Master Casts
    Mathey, Ayse
    Bragger, Urs
    Joda, Tim
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2021, 29 (03): : 152 - 159
  • [8] In Vitro Three-Dimensional Accuracy of Digital Implant Impressions: The Effect of Implant Angulation
    Chia, Vanessa A.
    Esguerra, Roxanna J.
    Teoh, Khim Hean
    Teo, Juin Wei
    Wong, Keng Mun
    Tan, Keson B.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (02) : 313 - 321
  • [9] In vivo trueness of full-arch implant-supported CAD/CAM restorations and models based on conventional impressions
    Nedelcu, Robert
    Olsson, Pontus
    Thulin, Mans
    Nystrom, Ingela
    Thor, Andreas
    JOURNAL OF DENTISTRY, 2023, 128
  • [10] Influence of Printing Angulation on the Accuracy (Trueness and Precision) of the Position of Implant Analogs in 3D Models: An In Vitro Pilot Study
    Garcia, Noelia
    Gomez-Polo, Miguel
    Fernandez, Miriam
    Antonaya-Martin, Jose Luis
    Ortega, Rocio
    Gomez-Polo, Cristina
    Revilla-Leon, Marta
    Cascos, Rocio
    APPLIED SCIENCES-BASEL, 2024, 14 (07):