Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

被引:2
|
作者
Onoral, Ozay [1 ]
Kurtulmus-Yilmaz, Sevcan [1 ]
Toksoy, Dilem [1 ]
Ozan, Oguz [1 ]
机构
[1] Near East Univ, Fac Dent, Dept Prosthodont, Mersin 10, Nicosia, Cyprus, Turkiye
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2023年 / 15卷 / 06期
关键词
Angulated implants; Closed tray; Splinted open tray; Intraoral scanners; Scan path; COMPARATIVE IN-VITRO; MULTIPLE IMPLANTS; SUBGINGIVAL DEPTH; ACCURACY; PROSTHESES; PRECISION; SCANNERS; IMPACT;
D O I
10.4047/jap.2023.15.6.290
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P <= .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.
引用
收藏
页码:290 / 301
页数:12
相关论文
共 50 条
  • [21] Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision
    Jeon, Jin-Hun
    Kim, Hae-Young
    Kim, Ji-Hwan
    Kim, Woong-Chul
    JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (06): : 468 - 473
  • [22] 3D printing of multi-unit gastro-retentive tablets for the pulsatile release of artesunate
    Yan, Wenrui
    Liu, Dongdong
    Xie, Hua
    Shen, Jintao
    Fang, Yubao
    Sun, Yingbao
    Jiao, Wencheng
    Jin, Yiguang
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2024, 658
  • [23] The Trueness of Obturator Prosthesis Base Manufactured by Conventional and 3D Printing Techniques
    Alfaraj, Amal
    Yang, Chao-Chieh
    Levon, John A.
    Chu, Tien-Min G.
    Morton, Dean
    Lin, Wei-Shao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (03): : 221 - 227
  • [24] Effect of relative volatility on the quantitative comparison of reactive distillation and conventional multi-unit systems
    Kaymak, DB
    Luyben, WL
    Smith, OJ
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2004, 43 (12) : 3151 - 3162
  • [25] Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions
    Akkal, Ozcan
    Korkmaz, Ismail Hakki
    Bayindir, Funda
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (04): : 179 - 188
  • [26] The 3D Position Estimation of Neurons in the Hippocampus Based on the Multi-site Multi-unit Recordings with Silicon Tetrodes
    Kubo, Takashi
    Katayama, Norihiro
    Karashima, Akibiro
    Nakao, Mitsuyuki
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 5021 - 5024
  • [27] Three-Dimensional Accuracy of Digital Impression versus Conventional Method: Effect of Implant Angulation and Connection Type
    Alikhasi, Marzieh
    Siadat, Hakime
    Nasirpour, Alireza
    Hasanzade, Mahya
    INTERNATIONAL JOURNAL OF DENTISTRY, 2018, 2018
  • [28] A digital workflow for pair matching of maxillary anterior teeth using a 3D segmentation technique for esthetic implant restorations
    Jin-Woo Choi
    Gyu-Jin Choi
    Yu-Seong Kim
    Min-Ho Kyung
    Hee-Kyung Kim
    Scientific Reports, 12
  • [29] A digital workflow for pair matching of maxillary anterior teeth using a 3D segmentation technique for esthetic implant restorations
    Choi, Jin-Woo
    Choi, Gyu-Jin
    Kim, Yu-Seong
    Kyung, Min-Ho
    Kim, Hee-Kyung
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [30] Can transfer type and implant angulation affect impression accuracy? A 3D in vitro evaluation
    Farronato, Davide
    Pasini, Pietro Mario
    Campana, Veronica
    Lops, Diego
    Azzi, Lorenzo
    Manfredini, Mattia
    ODONTOLOGY, 2021, 109 (04) : 884 - 894