Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

被引:2
|
作者
Onoral, Ozay [1 ]
Kurtulmus-Yilmaz, Sevcan [1 ]
Toksoy, Dilem [1 ]
Ozan, Oguz [1 ]
机构
[1] Near East Univ, Fac Dent, Dept Prosthodont, Mersin 10, Nicosia, Cyprus, Turkiye
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2023年 / 15卷 / 06期
关键词
Angulated implants; Closed tray; Splinted open tray; Intraoral scanners; Scan path; COMPARATIVE IN-VITRO; MULTIPLE IMPLANTS; SUBGINGIVAL DEPTH; ACCURACY; PROSTHESES; PRECISION; SCANNERS; IMPACT;
D O I
10.4047/jap.2023.15.6.290
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P <= .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.
引用
收藏
页码:290 / 301
页数:12
相关论文
共 50 条
  • [41] Comparison of conventional study model measurements and 3D digital study model measurements from laser scanned dental impressions
    Nugrahani, F.
    Jazaldi, F.
    Noerhadi, N. A. I.
    1ST PHYSICS AND TECHNOLOGIES IN MEDICINE AND DENTISTRY SYMPOSIUM, 2017, 884
  • [42] Accuracy of Multi-implant Impressions Using 3D-Printing Custom Trays and Splinting Versus Conventional Techniques for Complete Arches
    Liu, Yanping
    Di, Ping
    Zhao, Yijiao
    Hao, Qiang
    Tian, Jiehua
    Cui, Hongyan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (04) : 1007 - 1014
  • [43] The development of a 3D colour reproduction system of digital impressions with an intraoral scanner and a 3D printer: a preliminary study
    Liu, Yushu
    Zhang, Rui
    Ye, Hongqiang
    Wang, Shimin
    Wang, Kuan-Paul
    Liu, Yunsong
    Zhou, Yongsheng
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [44] The development of a 3D colour reproduction system of digital impressions with an intraoral scanner and a 3D printer: a preliminary study
    Yushu Liu
    Rui Zhang
    Hongqiang Ye
    Shimin Wang
    Kuan-Paul Wang
    Yunsong Liu
    Yongsheng Zhou
    Scientific Reports, 9
  • [45] Effect of support structures on the trueness and precision of 3D printing dentures: An in vitro study
    Namano, Sahaprom
    Kanazawa, Manabu
    Katheng, Awutsadaporn
    Trang, Bui Ngoc Huyen
    Hada, Tamaki
    Komagamine, Yuriko
    Iwaki, Maiko
    Minakuchi, Shunsuke
    JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (01) : 114 - 121
  • [46] Numerical reconstruction of digital holograms for conventional 3D display
    Pitkaaho, Tomi
    Naughton, Thomas J.
    2010 9TH EURO-AMERICAN WORKSHOP ON INFORMATION OPTICS, 2010,
  • [47] The effect of different abutment and restorative crown materials on stress distribution in single-unit implant-supported restorations: A 3D finite element stress analysis
    Gokcimen, Gulsum
    Durkan, Rukiye
    Gokay, Gonca
    Oyar, Perihan
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (05): : 497 - 505
  • [48] Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: An in vitro study
    Alkindi, Shaikha
    Hamdoon, Zaid
    Aziz, Ahmed M.
    JOURNAL OF DENTISTRY, 2024, 146
  • [49] Trueness of maxillary complete dentures duplicated by using conventional and 3D printing techniques: A comparative in vitro study
    Farahat, Amany Mostafa Saad
    Refai, Omnia M.
    Elsherbeeny, Yasmine Said
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03):
  • [50] The 3D emergence profile on implant-supported restorations: A method for evaluating restorative angles
    Mancini, Leonardo
    Thoma, Daniel S. S.
    Marchetti, Enrico
    Ernst, Jung Ronald
    Strauss, Franz J. J.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2023, 35 (08) : 1264 - 1270