Effect of Implant Divergence on the Accuracy of Definitive Casts Created from Traditional and Digital Implant-Level Impressions: An In Vitro Comparative Study

被引:65
|
作者
Lin, Wei-Shao [1 ]
Harris, Bryan T. [1 ]
Elathamna, Eiad N. [1 ]
Abdel-Azim, Tamer [1 ]
Morton, Dean [1 ,2 ]
机构
[1] Univ Louisville, Sch Dent, Dept Oral Hlth & Rehabil, Louisville, KY 40292 USA
[2] Univ Louisville, Sch Dent, Adv Educ Prosthodont, Louisville, KY 40292 USA
关键词
dental implants; dental impression technique; digital impression; implant divergence; parallel confocal technology; RESTORATIONS; ANGULATION; PROSTHESES; FIT; TECHNOLOGY; FRAMEWORK; ABUTMENT;
D O I
10.11607/jomi.3592
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this research was to compare the accuracy of definitive casts created with digital and conventional methods for implants with internal-octagon connections placed parallel or at different angles (15, 30, or 45 degrees). Materials and Methods: Four customized epoxy resin master casts were fabricated with two-implant analogs placed in the posterior mandible with different degrees of divergence. For the conventional (control) group, 10 traditional impressions were taken on each master cast with custom trays, open-tray impression copings, and polyvinyl siloxane; definitive stone casts were poured with type IV dental stone. For the digital group, 10 digital impressions were taken on each master cast with two-piece scannable impression copings and an intraoral digital scanner; definitive milled polyurethane casts were fabricated by the manufacturer. All four master casts and 80 control and test casts were scanned and digitized, and the data sets were compared. Any deviations in measurements between the definitive and corresponding master casts were analyzed statistically. Results: The amount of divergence between implants did not affect the accuracy of the stone casts created conventionally; however, it significantly affected the accuracy of the milled casts created digitally. A decreasing linear trend in deviations for both distance and angle measurements suggested that the digital technique was more accurate when the implants diverged more. At 0 and 15 degrees of divergence, the digital method resulted in highly significantly less accurate definitive casts. At 30 and 45 degrees of divergence, however, the milled casts showed either no difference or marginal differences with casts created conventionally. Conclusion: The digital pathway produced less accurate definitive casts than the conventional pathway with the tested two-implant scenarios. To ensure passive fit of definitive prostheses, verification devices and casts may be used when materials are produced digitally.
引用
收藏
页码:102 / 109
页数:8
相关论文
共 50 条
  • [1] Accuracy of printed casts generated from digital implant impressions versus stone casts from conventional implant impressions: A comparative in vitro study
    Alshawaf, Bahaa
    Weber, Hans-Peter
    Finkelman, Matthew
    El Rafie, Khaled
    Kudara, Yukio
    Papaspyridakos, Panos
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (08) : 835 - 842
  • [2] Accuracy of Casts Fabricated by Digital and Conventional Implant Impressions
    Bohner, Lauren
    Hanisch, Marcel
    Canto, Graziela De Luca
    Mukai, Eduardo
    Sesma, Newton
    Tortamano Neto, Pedro
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (02) : 94 - 99
  • [3] Displacement of implant components from impressions to definitive casts
    Kim, Sunjai
    Nicholls, Jack I.
    Han, Chong-Hyun
    Lee, Keun-Woo
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2006, 21 (05) : 747 - 755
  • [4] Accuracy of Definitive Casts Using 4 Implant-Level Impression Techniques in a Scenario of Multi-Implant System With Different Implant Angulations and Subgingival Alignment Levels
    Martinez-Rus, Francisco
    Garcia, Carmen
    Santamaria, Andrea
    Ozcan, Mutlu
    Pradies, Guillermo
    [J]. IMPLANT DENTISTRY, 2013, 22 (03) : 268 - 276
  • [5] In Vitro Three-Dimensional Accuracy of Digital Implant Impressions: The Effect of Implant Angulation
    Chia, Vanessa A.
    Esguerra, Roxanna J.
    Teoh, Khim Hean
    Teo, Juin Wei
    Wong, Keng Mun
    Tan, Keson B.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (02) : 313 - 321
  • [6] Accuracy of Digital Impressions at Varying Implant Depths: An In Vitro Study
    Sequeira, Vivia
    Harper, Matthew T.
    Lilly, Christa L.
    Bryington, Matthew S.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (01): : 54 - 61
  • [7] To evaluate and compare the accuracy of definitive casts using various splinting methods on implant level impressions in All-on-Four treatment: An in vitro study
    Shankar, S. Daya
    Doddamani, Santosh
    [J]. JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2020, 20 (02): : 193 - 201
  • [8] Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study
    Jo, Si-Hoon
    Kim, Kyoung-Ii
    Seo, Jae-Min
    Song, Kwang-Yeob
    Park, Ju-Mi
    Ahn, Seung-Geun
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (04): : 128 - 133
  • [9] Accuracy of Implant Casts Generated with Conventional and Digital ImpressionsAn In Vitro Study
    Ribeiro, Paulo
    Herrero-Climent, Mariano
    Diaz-Castro, Carmen
    Rios-Santos, Jose Vicente
    Padros, Roberto
    Mur, Javier Gil
    Falcao, Carlos
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (08):
  • [10] Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation
    Abduo, Jaafar
    Palamara, Joseph E. A.
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)