Effect of Implant Divergence on the Accuracy of Definitive Casts Created from Traditional and Digital Implant-Level Impressions: An In Vitro Comparative Study

被引:66
|
作者
Lin, Wei-Shao [1 ]
Harris, Bryan T. [1 ]
Elathamna, Eiad N. [1 ]
Abdel-Azim, Tamer [1 ]
Morton, Dean [1 ,2 ]
机构
[1] Univ Louisville, Sch Dent, Dept Oral Hlth & Rehabil, Louisville, KY 40292 USA
[2] Univ Louisville, Sch Dent, Adv Educ Prosthodont, Louisville, KY 40292 USA
关键词
dental implants; dental impression technique; digital impression; implant divergence; parallel confocal technology; RESTORATIONS; ANGULATION; PROSTHESES; FIT; TECHNOLOGY; FRAMEWORK; ABUTMENT;
D O I
10.11607/jomi.3592
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this research was to compare the accuracy of definitive casts created with digital and conventional methods for implants with internal-octagon connections placed parallel or at different angles (15, 30, or 45 degrees). Materials and Methods: Four customized epoxy resin master casts were fabricated with two-implant analogs placed in the posterior mandible with different degrees of divergence. For the conventional (control) group, 10 traditional impressions were taken on each master cast with custom trays, open-tray impression copings, and polyvinyl siloxane; definitive stone casts were poured with type IV dental stone. For the digital group, 10 digital impressions were taken on each master cast with two-piece scannable impression copings and an intraoral digital scanner; definitive milled polyurethane casts were fabricated by the manufacturer. All four master casts and 80 control and test casts were scanned and digitized, and the data sets were compared. Any deviations in measurements between the definitive and corresponding master casts were analyzed statistically. Results: The amount of divergence between implants did not affect the accuracy of the stone casts created conventionally; however, it significantly affected the accuracy of the milled casts created digitally. A decreasing linear trend in deviations for both distance and angle measurements suggested that the digital technique was more accurate when the implants diverged more. At 0 and 15 degrees of divergence, the digital method resulted in highly significantly less accurate definitive casts. At 30 and 45 degrees of divergence, however, the milled casts showed either no difference or marginal differences with casts created conventionally. Conclusion: The digital pathway produced less accurate definitive casts than the conventional pathway with the tested two-implant scenarios. To ensure passive fit of definitive prostheses, verification devices and casts may be used when materials are produced digitally.
引用
收藏
页码:102 / 109
页数:8
相关论文
共 50 条
  • [41] Evaluation of the effect of implant angulations and impression techniques on implant cast accuracy u An in vitro study
    Arora, Aman
    Upadhyaya, Viram
    Parashar, Kirti R.
    Malik, Divya
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2019, 19 (02): : 149 - 158
  • [42] Effect of custom abutment data superimposition on the accuracy of implant abutment level scanning: An in vitro study
    Baek, Yeon-Wha
    Lim, Young-Jun
    Kim, Myung-Joo
    Kwon, Ho-Beom
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1208 - 1217
  • [43] A comparative clinical study on the transfer accuracy of conventional and digital implant impressions using a new reference key-based method
    Schmidt, Alexander
    Rein, Peter Engelbert
    Woestmann, Bernd
    Schlenz, Maximiliane Amelie
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (04) : 460 - 469
  • [44] Digital versus radiographic accuracy evaluation of guided implant surgery: an in vitro study
    Chun Yi
    Sha Li
    Aonan Wen
    Yong Wang
    Yijiao Zhao
    Yu Zhang
    BMC Oral Health, 22
  • [45] Digital versus radiographic accuracy evaluation of guided implant surgery: an in vitro study
    Yi, Chun
    Li, Sha
    Wen, Aonan
    Wang, Yong
    Zhao, Yijiao
    Zhang, Yu
    BMC ORAL HEALTH, 2022, 22 (01)
  • [46] Effect of Scan Pattern on the Accuracy of Complete-Arch Digital Implant Impressions with Two Intraoral Scanners
    Li, Zhipeng
    Huang, Ruoxuan
    Wu, Xiayi
    Chen, Zetao
    Huang, Baoxin
    Chen, Zhuofan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 731 - 739
  • [47] Effect of prefabricated auxiliary devices and scanning patterns on the accuracy of complete-arch implant digital impressions
    Wu, Hio Kuan
    Chen, Guanhui
    Wang, Jing
    Zhang, Zhengchuan
    Huang, Xiaoqiong
    Lin, Xiaoxuan
    Deng, Feilong
    Li, Yiming
    JOURNAL OF DENTISTRY, 2024, 140
  • [48] Effect of implant shape and length on the accuracy of robot-assisted immediate implant surgery: An in vitro study
    Wang, Yunxiao
    Yu, Shimin
    Wang, Yulan
    Feng, Yi
    Yan, Qi
    Zhang, Yufeng
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (03) : 350 - 357
  • [49] Trueness and Precision Achieved With Conventional and Digital Implant Impressions: A Comparative Investigation of Stone Versus 3-D Printed Master Casts
    Mathey, Ayse
    Bragger, Urs
    Joda, Tim
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2021, 29 (03): : 152 - 159
  • [50] A comparative analysis of the accuracy of implant master casts fabricated from two different transfer impression techniques
    Patil, Rupali
    Kadam, Pankaj
    Oswal, Chetan
    Patil, Seema
    Jajoo, Shweta
    Gachake, Arati
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2016, 6 (02): : 142 - 148