Enhancement of soft-tissue contrast in cone-beam CT using an anti-scatter grid with a sparse sampling approach

被引:17
|
作者
Cho, Sanghoon [1 ]
Lim, Sunho [1 ]
Kim, Changhwan [1 ]
Wi, Sunhee [1 ]
Kwon, Taejin [1 ]
Youn, Won Sik [2 ]
Lee, Sang Hyun [2 ]
Kang, Bo Sun [3 ]
Cho, Seungryong [1 ,4 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Daejeon, South Korea
[2] JPI Healthcare Co Ltd, Dept Res & Dev, Ansan, South Korea
[3] Konyang Univ, Dept Radiol Sci, Daejeon, South Korea
[4] KAIST Inst Hlth Sci & Technol IT Convergence & Ar, Daejeon, South Korea
基金
新加坡国家研究基金会;
关键词
Cone-beam CT (CBCT); Anti-scatter grid; Scatter correction; COMPUTED-TOMOGRAPHY; ANTISCATTER GRIDS; RECONSTRUCTION; ALGORITHM; OPTIMIZATION; STATISTICS;
D O I
10.1016/j.ejmp.2020.01.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Anti-scatter grids suppress the scatter substantially thus improving image contrast in radiography. However, its active use in cone-beam CT for the purpose of improving contrast-to-noise ratio (CNR) has not been successful mainly due to the increased noise related to Poisson statistics of photons. This paper proposes a sparse-view scanning approach to address the above issue. Method: Compared to the conventional cone-beam CT imaging framework, the proposed method reduces the number of projections and increases exposure in each projection to enhance image quality without an additional cost of radiation dose to patients. For image reconstruction from sparse-view data, an adaptive-steepest-descent projection-onto-convex-sets (ASD POCS) algorithm regularized by total-variation (TV) minimization was adopted. Contrast and CNR with various scattering conditions were evaluated in projection domain by a simulation study using GATE. Then we evaluated contrast, resolution, and image uniformity in CT image domain with Catphan phantom. A head phantom with soft-tissue structures was also employed for demonstrating a realistic application. A virtual grid-based estimation and reduction of scatter has also been implemented for comparison with the real anti-scatter grid. Results: In the projection domain evaluation, contrast and CNR enhancement was observed when using an anti-scatter grid compared to the virtual grid. In the CT image domain, the proposed method produced substantially higher contrast and CNR of the low-contrast structures with much improved image uniformity. Conclusion: We have shown that the proposed method can provide high-quality CBCT images particularly with an increased contrast of soft-tissue at a neutral dose for image-guidance.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [31] Contrast Enhancement on Cone-Beam Breast-CT for Discrimination of Breast Cancer Immunohistochemical Subtypes
    Uhlig, Johannes
    Fischer, Uwe
    von Fintel, Eva
    Stahnke, Vera
    Perske, Christina
    Lotz, Joachim
    Wienbeck, Susanne
    TRANSLATIONAL ONCOLOGY, 2017, 10 (06): : 904 - 910
  • [32] Exploration of Soft-Tissue Visualization at Low Dose Using Flat-Panel Imagers Incorporating Thick, Segmented Scintillators for Megavoltage Cone-Beam CT
    El-Mohri, Y.
    Antonuk, L.
    Zhao, Q.
    Wang, Y.
    Du, H.
    Koniczek, M.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [33] Optimization of a Collimator-Based Sparse Sampling Technique for Low-Dose Cone-Beam CT
    Lee, T.
    Kim, I.
    Han, B.
    Cho, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3201 - 3201
  • [34] Reproducibility of Facial Soft Tissue Thickness Measurements Using Cone-Beam CT Images According to the Measurement Methods
    Hwang, Hyeon-Shik
    Choe, Seon-Yeong
    Hwang, Ji-Sup
    Moon, Da-Nal
    Hou, Yanan
    Lee, Won-Joon
    Wilkinson, Caroline
    JOURNAL OF FORENSIC SCIENCES, 2015, 60 (04) : 957 - 965
  • [35] Scatter Reduction and Correction for Dual-Source Cone-Beam CT Using Prepatient Grids
    Ren, Lei
    Chen, Yingxuan
    Zhang, You
    Giles, William
    Jin, Jianyue
    Yin, Fang-Fang
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (03) : 416 - 427
  • [36] Robust scatter correction method for cone-beam CT using an interlacing-slit plate
    黄魁东
    徐哲
    张定华
    张华
    时稳龙
    Chinese Physics C, 2016, (06) : 99 - 106
  • [37] Scatter correction of cone-beam CT using a deep residual convolution neural network (DRCNN)
    Jiang, Yangkang
    Yang, Chunlin
    Yang, Pengfei
    Hu, Xi
    Luo, Chen
    Xue, Yi
    Xu, Lei
    Hu, Xiuhua
    Zhang, Luhan
    Wang, Jing
    Sheng, Ke
    Niu, Tianye
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (14):
  • [38] Volume changes in soft tissue sarcomas during preoperative radiotherapy of extremities evaluated using cone-beam CT
    Betgen, Anja
    Haas, Rick L. M.
    Sonke, Jan-Jakob
    JOURNAL OF RADIATION ONCOLOGY, 2013, 2 (01) : 55 - 62
  • [39] Robust scatter correction method for cone-beam CT using an interlacing-slit plate
    黄魁东
    徐哲
    张定华
    张华
    时稳龙
    Chinese Physics C, 2016, 40 (06) : 99 - 106
  • [40] SCATTER REDUCTION IN CONE-BEAM CT USING A SCANNING CYLINDRICAL APERTURE TOMOGRAPHIC (SCAT) DEVICE
    RUDIN, S
    BEDNAREK, DR
    MEDICAL PHYSICS, 1980, 7 (04) : 428 - 428