Enhancement of soft-tissue contrast in cone-beam CT using an anti-scatter grid with a sparse sampling approach

被引:17
|
作者
Cho, Sanghoon [1 ]
Lim, Sunho [1 ]
Kim, Changhwan [1 ]
Wi, Sunhee [1 ]
Kwon, Taejin [1 ]
Youn, Won Sik [2 ]
Lee, Sang Hyun [2 ]
Kang, Bo Sun [3 ]
Cho, Seungryong [1 ,4 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Daejeon, South Korea
[2] JPI Healthcare Co Ltd, Dept Res & Dev, Ansan, South Korea
[3] Konyang Univ, Dept Radiol Sci, Daejeon, South Korea
[4] KAIST Inst Hlth Sci & Technol IT Convergence & Ar, Daejeon, South Korea
基金
新加坡国家研究基金会;
关键词
Cone-beam CT (CBCT); Anti-scatter grid; Scatter correction; COMPUTED-TOMOGRAPHY; ANTISCATTER GRIDS; RECONSTRUCTION; ALGORITHM; OPTIMIZATION; STATISTICS;
D O I
10.1016/j.ejmp.2020.01.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Anti-scatter grids suppress the scatter substantially thus improving image contrast in radiography. However, its active use in cone-beam CT for the purpose of improving contrast-to-noise ratio (CNR) has not been successful mainly due to the increased noise related to Poisson statistics of photons. This paper proposes a sparse-view scanning approach to address the above issue. Method: Compared to the conventional cone-beam CT imaging framework, the proposed method reduces the number of projections and increases exposure in each projection to enhance image quality without an additional cost of radiation dose to patients. For image reconstruction from sparse-view data, an adaptive-steepest-descent projection-onto-convex-sets (ASD POCS) algorithm regularized by total-variation (TV) minimization was adopted. Contrast and CNR with various scattering conditions were evaluated in projection domain by a simulation study using GATE. Then we evaluated contrast, resolution, and image uniformity in CT image domain with Catphan phantom. A head phantom with soft-tissue structures was also employed for demonstrating a realistic application. A virtual grid-based estimation and reduction of scatter has also been implemented for comparison with the real anti-scatter grid. Results: In the projection domain evaluation, contrast and CNR enhancement was observed when using an anti-scatter grid compared to the virtual grid. In the CT image domain, the proposed method produced substantially higher contrast and CNR of the low-contrast structures with much improved image uniformity. Conclusion: We have shown that the proposed method can provide high-quality CBCT images particularly with an increased contrast of soft-tissue at a neutral dose for image-guidance.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] Reproducibility of Facial Soft Tissue Thicknesses for Craniofacial Reconstruction Using Cone-Beam CT Images
    Hwang, Hyeon-Shik
    Kim, Kyul
    Moon, Da-Nal
    Kim, Jae-Hyung
    Wilkinson, Caroline
    JOURNAL OF FORENSIC SCIENCES, 2012, 57 (02) : 443 - 448
  • [22] Image Quality Optimization and Soft Tissue Visualization in Cone-Beam CT Imaging
    Castonguay-Henri, Aude
    Matenine, Dmitri
    Schmittbuhl, Matthieu
    de Guise, Jacques A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 283 - 288
  • [23] Soft-tissue detectability in cone-beam CT: Evaluation by 2AFC tests in relation to physical performance metrics
    Tward, D. J.
    Siewerdsen, J. H.
    Daly, M. J.
    Richard, S.
    Moseley, D. J.
    Jaffray, D. A.
    Paul, N. S.
    MEDICAL PHYSICS, 2007, 34 (11) : 4459 - 4471
  • [24] Clinical study of soft-tissue contrast resolution in cone-beam CT of the head using multi-resolution PWLS with multi-motion correction and an electronic noise model
    Wu, P.
    Sisniega, A.
    Stayman, J. W.
    Zbijewski, W.
    Foos, D.
    Wang, X.
    Aygun, N.
    Stevens, R.
    Siewerdsen, J. H.
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [25] Soft tissue contrast resolution within the head of human cadaver by means of flat detector based cone-beam CT
    Wiegert, J
    Bertram, M
    Schäfer, D
    Conrads, N
    Noordhoek, N
    de Jong, K
    Aach, T
    Rose, G
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 330 - 337
  • [26] Feasibility of improving cone-beam CT number consistency using a scatter correction algorithm
    Li, Jun
    Yao, Weiguang
    Xiao, Ying
    Yu, Yan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (06): : 167 - 176
  • [27] Local filtration based scatter correction for cone-beam CT using primary modulation
    Zhu, Lei
    MEDICAL PHYSICS, 2016, 43 (11) : 6199 - 6209
  • [28] Soft-tissue changes after maxillomandibular advancement surgery assessed with cone-beam computed tomography
    Ryckman, Michael S.
    Harrison, Steven
    Oliver, Don
    Sander, Christian
    Boryor, Andrew A.
    Hohmann, Ansgar A.
    Kilic, Fatih
    Kim, Ki Beom
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : S86 - S93
  • [29] X-Ray Scatter Correction on Soft Tissue Images for Portable Cone Beam CT
    Aootaphao, Sorapong
    Thongvigitmanee, Saowapak S.
    Rajruangrabin, Jartuwat
    Thanasupsombat, Chalinee
    Srivongsa, Tanapon
    Thajchayapong, Pairash
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [30] 3D-printed large-area focused grid for scatter reduction in cone-beam CT
    Cobos, Santiago Fabian
    Norley, Christopher James
    Nikolov, Hristo Nikolaev
    Holdsworth, David Wayne
    MEDICAL PHYSICS, 2023, 50 (01) : 240 - 258