Three-dimensional breathhold magnetization-prepared TrueFISP - A pilot study for magnetic resonance imaging of the coronary artery disease

被引:22
|
作者
McCarthy, Richard M.
Deshpande, Vibhas S.
Beohar, Nirat
Meyers, Sheridan N.
Shea, Steven M.
Green, Jordin D.
Liu, Xin
Bi, Xiaoming
Pereles, F. Scott
Finn, John Paul
Davidson, Charles J.
Carr, James C.
Li, Debiao
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Med, Chicago, IL 60611 USA
关键词
angiography; atherosclerosis; coronary disease; magnetic resonance imaging; sensitivity;
D O I
10.1097/RLI.0b013e3180661a77
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: X-ray angiography is currently the standard test for the assessment of coronary artery disease. A substantial minority of patients referred for coronary angiography have no significant coronary artery disease. The purpose of this work was the evaluation of the accuracy of a three-dimensional (3D) breathhold coronary magnetic resonance angiography (MRA) technique in detecting hemo-dynamically significant coronary artery stenoses in a patient population with x-ray angiographic correlation. Materials and Methods: Sequential subjects (n = 33, M/F 22/11, average age = 57) who were referred for conventional coronary angiography were enrolled in the study. The study protocol was approved by our institutional review board. Each subject gave written informed consent. Volume-targeted 3D breathhold coronary artery scans with ECG-triggered, segmented True Fast Imaging with Steady-state Precession (TrueFISP) were acquired for the left main (LM), left anterior descending (LAD), and right coronary arteries (RCAs). Coronary MRA was evaluated with conventional angiography as the gold standard. Results: The overall sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) for diagnosing any hemodynamically significant coronary artery disease ( >= 50% diameter reduction) with coronary MRA was 87%, 57%, 72%, 68%, and 80%, respectively. The sensitivity of the technique in the LM, LAD, and RCA was 100%, 83%, and 100%, respectively. The NPV of the technique in the LM, LAD, and RCA was 100%, 82%, and 100%, respectively. Conclusions: Three-dimensional breathhold True Fast Imaging with Steady-state Precession is a promising technique for coronary artery imaging. It has a relatively high sensitivity and NPV. Results of this study warrant further technical improvements and clinical evaluation of the technique.
引用
收藏
页码:665 / 670
页数:6
相关论文
共 50 条
  • [31] MR angiography of the coronary arteries using magnetization-prepared contrast-enhanced breathhold volume-targeted imaging (MPCE-VCATS): Initial clinical experience
    Carr, JC
    Tahlerl, H
    Shea, S
    Deshpande, VS
    Finn, JP
    Li, D
    RADIOLOGY, 2000, 217 : 285 - 285
  • [32] Comparison of Real-Time Three-Dimensional Speckle Tracking to Magnetic Resonance Imaging in Patients With Coronary Heart Disease
    Hayat, Delphine
    Kloeckner, Martin
    Nahum, Julien
    Ecochard-Dugelay, Emmanuelle
    Dubois-Rande, Jean-Luc
    Jean-Francois, Deux
    Gueret, Pascal
    Lim, Pascal
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (02): : 180 - 186
  • [33] Normal Three-Dimensional Pulmonary Artery Flow Determined by Phase Contrast Magnetic Resonance Imaging
    Victoria L. Morgan
    Robert J. Roselli
    Christine H. Lorenz
    Annals of Biomedical Engineering, 1998, 26 : 557 - 566
  • [34] Three-Dimensional High-Resolution Magnetic Resonance Imaging for the Assessment of Cervical Artery Dissection
    Zhu, Xianjin
    Shan, Yi
    Guo, Runcai
    Zheng, Tao
    Zhang, Xuebin
    Liu, Zunjing
    Liu, Kunpeng
    FRONTIERS IN AGING NEUROSCIENCE, 2022, 14
  • [35] Normal three-dimensional pulmonary artery flow determined by phase contrast magnetic resonance imaging
    Morgan, VL
    Roselli, RJ
    Lorenz, CH
    ANNALS OF BIOMEDICAL ENGINEERING, 1998, 26 (04) : 557 - 566
  • [36] Visualization of the coronary arteries in three-dimensional reconstructions using respiratory gated magnetic resonance imaging
    Achenbach, S
    Kessler, W
    Moshage, WE
    Ropers, D
    Zink, D
    Kroeker, R
    Nitz, W
    Laub, G
    Bachmann, K
    CORONARY ARTERY DISEASE, 1997, 8 (07) : 441 - 448
  • [37] Coronary magnetic resonance angiography using magnetization-prepared contrast-enhanced breath-hold volume-targeted imaging (MPCE-VCATS)
    Yang, Carina W.
    Carr, James C.
    Francois, Christopher J.
    Shea, Steven M.
    Deshpande, Vibhas S.
    Meyers, Sheridan N.
    Beohar, Nirat
    Finn, J. Paul
    Li, Debiao
    INVESTIGATIVE RADIOLOGY, 2006, 41 (08) : 639 - 644
  • [38] Three-dimensional morphological magnetic resonance imaging in infants and children with congenital heart disease
    Fenchel, Michael
    Greil, Gerald F.
    Martirosian, Petros
    Kramer, Ulrich
    Schick, Fritz
    Claussen, Claus D.
    Sieverding, Ludger
    Miller, Stephan
    PEDIATRIC RADIOLOGY, 2006, 36 (12) : 1265 - 1272
  • [39] Three-dimensional morphological magnetic resonance imaging in infants and children with congenital heart disease
    Michael Fenchel
    Gerald F. Greil
    Petros Martirosian
    Ulrich Kramer
    Fritz Schick
    Claus D. Claussen
    Ludger Sieverding
    Stephan Miller
    Pediatric Radiology, 2006, 36 : 1265 - 1272
  • [40] Three-dimensional imaging of orthodontic models: a pilot study
    Asquith, Jennifer
    Gillgrass, Toby
    Mossey, Peter
    EUROPEAN JOURNAL OF ORTHODONTICS, 2007, 29 (05) : 517 - 522