Three-dimensional breathhold magnetization-prepared TrueFISP - A pilot study for magnetic resonance imaging of the coronary artery disease

被引:22
|
作者
McCarthy, Richard M.
Deshpande, Vibhas S.
Beohar, Nirat
Meyers, Sheridan N.
Shea, Steven M.
Green, Jordin D.
Liu, Xin
Bi, Xiaoming
Pereles, F. Scott
Finn, John Paul
Davidson, Charles J.
Carr, James C.
Li, Debiao
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Med, Chicago, IL 60611 USA
关键词
angiography; atherosclerosis; coronary disease; magnetic resonance imaging; sensitivity;
D O I
10.1097/RLI.0b013e3180661a77
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: X-ray angiography is currently the standard test for the assessment of coronary artery disease. A substantial minority of patients referred for coronary angiography have no significant coronary artery disease. The purpose of this work was the evaluation of the accuracy of a three-dimensional (3D) breathhold coronary magnetic resonance angiography (MRA) technique in detecting hemo-dynamically significant coronary artery stenoses in a patient population with x-ray angiographic correlation. Materials and Methods: Sequential subjects (n = 33, M/F 22/11, average age = 57) who were referred for conventional coronary angiography were enrolled in the study. The study protocol was approved by our institutional review board. Each subject gave written informed consent. Volume-targeted 3D breathhold coronary artery scans with ECG-triggered, segmented True Fast Imaging with Steady-state Precession (TrueFISP) were acquired for the left main (LM), left anterior descending (LAD), and right coronary arteries (RCAs). Coronary MRA was evaluated with conventional angiography as the gold standard. Results: The overall sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) for diagnosing any hemodynamically significant coronary artery disease ( >= 50% diameter reduction) with coronary MRA was 87%, 57%, 72%, 68%, and 80%, respectively. The sensitivity of the technique in the LM, LAD, and RCA was 100%, 83%, and 100%, respectively. The NPV of the technique in the LM, LAD, and RCA was 100%, 82%, and 100%, respectively. Conclusions: Three-dimensional breathhold True Fast Imaging with Steady-state Precession is a promising technique for coronary artery imaging. It has a relatively high sensitivity and NPV. Results of this study warrant further technical improvements and clinical evaluation of the technique.
引用
收藏
页码:665 / 670
页数:6
相关论文
共 50 条
  • [21] Three-dimensional magnetic resonance imaging of fetal brains
    Schierlitz, L
    Dumanli, H
    Robinson, JN
    Burrows, PE
    Schreyer, AG
    Kikinis, R
    Jolesz, FA
    Tempany, MCM
    LANCET, 2001, 357 (9263): : 1177 - 1178
  • [22] Three-Dimensional Magnetic Resonance Imaging of Velopharyngeal Structures
    Bae, Youkyung
    Kuehn, David P.
    Sutton, Bradley P.
    Conway, Charles A.
    Perry, Jamie L.
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2011, 54 (06): : 1538 - 1545
  • [23] Three-Dimensional Magnetic Resonance Imaging in the Musculoskeletal System
    Ahlawat, Shivani
    Kumar, Neil M.
    Ghasemi, Ali
    Fayad, Laura M.
    INVESTIGATIVE RADIOLOGY, 2025, 60 (03) : 184 - 197
  • [24] Three-dimensional magnetic resonance imaging of a liquid foam
    1600, Institute of Physics Publishing Ltd, Bristol, Engl (07):
  • [25] Navigator-gated free-breathing three-dimensional balanced fast field echo (TrueFISP) coronary magnetic resonance angiography
    Spuentrup, E
    Börnert, P
    Botnar, RM
    Groen, JP
    Manning, WJ
    Stuber, M
    INVESTIGATIVE RADIOLOGY, 2002, 37 (11) : 637 - 642
  • [26] Three-dimensional black-blood cardiac magnetic resonance coronary vessel wall imaging detects positive arterial remodeling in patients with nonsignificant coronary artery disease
    Kim, WY
    Stuber, M
    Börnert, P
    Kissinger, KV
    Manning, WJ
    Botnar, RM
    CIRCULATION, 2002, 106 (03) : 296 - 299
  • [27] Free-breathing, three-dimensional coronary artery magnetic resonance angiography: Comparison of sequences
    Weber, OM
    Pujadas, S
    Martin, AJ
    Higgins, CB
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (03) : 395 - 402
  • [28] Quantitative assessment of carotid artery atherosclerosis by three-dimensional magnetic resonance and two-dimensional ultrasound imaging: a comparison study
    Qiao, Huiyu
    Cai, Ying
    Huang, Manwei
    Liu, Yang
    Qiang, Zhang
    Huang, Lingyun
    Chen, Huijun
    Yuan, Chun
    Zhao, Xihai
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (05) : 1021 - 1032
  • [29] Three-dimensional whole heart magnetic resonance imaging of anomalous origin of the right coronary artery from the left sinus of Valsalva
    Sato, Y.
    Matsumoto, N.
    Saito, S.
    HEART, 2007, 93 (08) : 907 - 907
  • [30] Does the eye only rotate? : A three-dimensional magnetic resonance imaging study
    Song, Yumi
    Hwang, Sunjin
    Lee, Won June
    Kim, Yu Jeong
    Ahn, Seong Joon
    Lee, Byung Ro
    Lim, Han Woong
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)