Three-dimensional breathhold magnetization-prepared TrueFISP - A pilot study for magnetic resonance imaging of the coronary artery disease

被引:22
|
作者
McCarthy, Richard M.
Deshpande, Vibhas S.
Beohar, Nirat
Meyers, Sheridan N.
Shea, Steven M.
Green, Jordin D.
Liu, Xin
Bi, Xiaoming
Pereles, F. Scott
Finn, John Paul
Davidson, Charles J.
Carr, James C.
Li, Debiao
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Med, Chicago, IL 60611 USA
关键词
angiography; atherosclerosis; coronary disease; magnetic resonance imaging; sensitivity;
D O I
10.1097/RLI.0b013e3180661a77
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: X-ray angiography is currently the standard test for the assessment of coronary artery disease. A substantial minority of patients referred for coronary angiography have no significant coronary artery disease. The purpose of this work was the evaluation of the accuracy of a three-dimensional (3D) breathhold coronary magnetic resonance angiography (MRA) technique in detecting hemo-dynamically significant coronary artery stenoses in a patient population with x-ray angiographic correlation. Materials and Methods: Sequential subjects (n = 33, M/F 22/11, average age = 57) who were referred for conventional coronary angiography were enrolled in the study. The study protocol was approved by our institutional review board. Each subject gave written informed consent. Volume-targeted 3D breathhold coronary artery scans with ECG-triggered, segmented True Fast Imaging with Steady-state Precession (TrueFISP) were acquired for the left main (LM), left anterior descending (LAD), and right coronary arteries (RCAs). Coronary MRA was evaluated with conventional angiography as the gold standard. Results: The overall sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) for diagnosing any hemodynamically significant coronary artery disease ( >= 50% diameter reduction) with coronary MRA was 87%, 57%, 72%, 68%, and 80%, respectively. The sensitivity of the technique in the LM, LAD, and RCA was 100%, 83%, and 100%, respectively. The NPV of the technique in the LM, LAD, and RCA was 100%, 82%, and 100%, respectively. Conclusions: Three-dimensional breathhold True Fast Imaging with Steady-state Precession is a promising technique for coronary artery imaging. It has a relatively high sensitivity and NPV. Results of this study warrant further technical improvements and clinical evaluation of the technique.
引用
收藏
页码:665 / 670
页数:6
相关论文
共 50 条
  • [11] Magnetic resonance angiography of coronary arteries with a 3-dimensional magnetization-prepared true fast imaging with steady-state precession sequence compared with conventional coronary angiography
    Man-ching, N
    Lam, WW
    Li, D
    Chan, AK
    Sanderson, JE
    Metreweli, C
    AMERICAN HEART JOURNAL, 2005, 150 (03) : 530 - 535
  • [12] Three-dimensional magnetic resonance imaging for groundwater
    Legchenko, A.
    Descloitres, M.
    Vincent, C.
    Guyard, H.
    Garambois, S.
    Chalikakis, K.
    Ezersky, M.
    NEW JOURNAL OF PHYSICS, 2011, 13
  • [13] Coronary arteries: Magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography
    Li, DB
    Carr, JC
    Shea, SM
    Zheng, J
    Deshpande, VS
    Wielopolski, PA
    Finn, JP
    RADIOLOGY, 2001, 219 (01) : 270 - 277
  • [14] Values of three-dimensional speckle tracking imaging for the diagnosis of coronary artery disease
    Zhao, Dexia
    Zhou, Zhenfang
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2024, 58 (01)
  • [15] Three-dimensional Imaging of coronary artery bypass grafts
    Sawamura, Y
    Takase, K
    Saito, H
    Kikuchi, S
    Ito, T
    ANNALS OF THORACIC SURGERY, 2002, 73 (05): : 1655 - 1655
  • [16] MAGNETIZATION-PREPARED RAPID GRADIENT ECHO (MP-RAGE) MAGNETIC-RESONANCE-IMAGING OF MORGAGNIS HERNIA
    DELANGE, EE
    URBANSKI, SR
    MUGLER, JP
    BROOKEMAN, JR
    EUROPEAN JOURNAL OF RADIOLOGY, 1990, 11 (03) : 196 - 199
  • [17] Multicenter Evaluation of Dynamic Three-Dimensional Magnetic Resonance Myocardial Perfusion Imaging for the Detection of Coronary Artery Disease Defined by Fractional Flow Reserve
    Manka, Robert
    Wissmann, Lukas
    Gebker, Rolf
    Jogiya, Roy
    Motwani, Manish
    Frick, Michael
    Reinartz, Sebastian
    Schnackenburg, Bernhard
    Niemann, Markus
    Gotschy, Alexander
    Kuhl, Christiane
    Nagel, Eike
    Fleck, Eckart
    Marx, Nikolaus
    Luescher, Thomas F.
    Plein, Sven
    Kozerke, Sebastian
    CIRCULATION-CARDIOVASCULAR IMAGING, 2015, 8 (05)
  • [18] Magnetic resonance imaging in the assessment of coronary artery disease
    Ray T.
    Biederman R.W.
    Doyle M.
    Mankad S.
    Current Atherosclerosis Reports, 2005, 7 (2) : 108 - 114
  • [19] CARDIAC MAGNETIC RESONANCE IMAGING FOR CORONARY ARTERY DISEASE
    Sozzi, F.
    Iacuzio, L.
    Canetta, C.
    Civaia, F.
    Rusek, S.
    Rossi, P.
    Hugues, N.
    Lombardi, F.
    Dreyfus, G.
    Dor, V.
    CARDIOLOGY, 2014, 128 : 32 - 32
  • [20] Three-dimensional black-blood magnetic resonance coronary vessel wall imaging
    Kim, WY
    Botnar, RM
    Stuber, M
    Börnert, P
    Manning, WJ
    CIRCULATION, 2001, 104 (17) : 375 - 375