Three-dimensional breathhold magnetization-prepared TrueFISP - A pilot study for magnetic resonance imaging of the coronary artery disease

被引:22
|
作者
McCarthy, Richard M.
Deshpande, Vibhas S.
Beohar, Nirat
Meyers, Sheridan N.
Shea, Steven M.
Green, Jordin D.
Liu, Xin
Bi, Xiaoming
Pereles, F. Scott
Finn, John Paul
Davidson, Charles J.
Carr, James C.
Li, Debiao
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Med, Chicago, IL 60611 USA
关键词
angiography; atherosclerosis; coronary disease; magnetic resonance imaging; sensitivity;
D O I
10.1097/RLI.0b013e3180661a77
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: X-ray angiography is currently the standard test for the assessment of coronary artery disease. A substantial minority of patients referred for coronary angiography have no significant coronary artery disease. The purpose of this work was the evaluation of the accuracy of a three-dimensional (3D) breathhold coronary magnetic resonance angiography (MRA) technique in detecting hemo-dynamically significant coronary artery stenoses in a patient population with x-ray angiographic correlation. Materials and Methods: Sequential subjects (n = 33, M/F 22/11, average age = 57) who were referred for conventional coronary angiography were enrolled in the study. The study protocol was approved by our institutional review board. Each subject gave written informed consent. Volume-targeted 3D breathhold coronary artery scans with ECG-triggered, segmented True Fast Imaging with Steady-state Precession (TrueFISP) were acquired for the left main (LM), left anterior descending (LAD), and right coronary arteries (RCAs). Coronary MRA was evaluated with conventional angiography as the gold standard. Results: The overall sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) for diagnosing any hemodynamically significant coronary artery disease ( >= 50% diameter reduction) with coronary MRA was 87%, 57%, 72%, 68%, and 80%, respectively. The sensitivity of the technique in the LM, LAD, and RCA was 100%, 83%, and 100%, respectively. The NPV of the technique in the LM, LAD, and RCA was 100%, 82%, and 100%, respectively. Conclusions: Three-dimensional breathhold True Fast Imaging with Steady-state Precession is a promising technique for coronary artery imaging. It has a relatively high sensitivity and NPV. Results of this study warrant further technical improvements and clinical evaluation of the technique.
引用
收藏
页码:665 / 670
页数:6
相关论文
共 50 条
  • [1] Coronary arteries at 3.0 T: Contrast-enhanced magnetization-prepared three-dimensional breathhold MR angiography
    Bi, XM
    Li, DB
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) : 133 - 139
  • [2] Three-Dimensional Magnetization-Prepared Imaging Using a Concentric Cylinders Trajectory
    Kwon, Kie Tae
    Wu, Holden H.
    Shin, Taehoon
    Cukur, Tolga
    Lustig, Michael
    Nishimura, Dwight G.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) : 1700 - 1710
  • [3] 3D magnetization-prepared TrueFISP: Initial clinical evaluation of a new MR technique for imaging coronary arteries
    McCarthy, R
    Deshpande, VS
    Shea, S
    Finn, JP
    Li, D
    RADIOLOGY, 2001, 221 : 588 - 588
  • [4] Improved centric phase encoding orders for three-dimensional magnetization-prepared MR angiography
    Wilman, AH
    Riederer, SJ
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) : 384 - 392
  • [5] Breathhold three-dimensional coronary magnetic resonance angiography using real-time navigator technology
    Stuber, M
    Botnar, RM
    Danias, PG
    Kissinger, KV
    Manning, WJ
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 1999, 1 (03) : 233 - 238
  • [6] A pilot study comparing three-dimensional models of tumor histopathology and magnetic resonance imaging
    Koivuholma, Anne
    Sistonen, Heli J.
    Aro, Katri
    Makitie, Antti
    Hagstrom, Jaana
    Atula, Timo
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [7] Magnetic resonance imaging of the coronary arteries: anatomy of the coronary arteries and veins in three-dimensional imaging
    van Geuns, RJM
    Wielopolski, PA
    Rensing, BJWM
    van Ooijen, PMA
    Oudkerk, M
    de Feyter, PJ
    CORONARY ARTERY DISEASE, 1999, 10 (04) : 261 - 267
  • [8] Detection and assessment of coronary artery anomalies by three-dimensional magnetic resonance coronary angiography
    Casolo, G
    Del Meglio, J
    Rega, L
    Manta, R
    Margheri, M
    Villari, N
    Gensini, G
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 103 (03) : 317 - 322
  • [9] Accuracy of dynamic three-dimensional magnetic resonance perfusion imaging for the detection of coronary artery disease in patients with reduced ejection fraction
    Oebel, Sabrina
    Gotschy, Alexander
    Paetsch, Ingo
    Jahnke, Cosima
    Plein, Sven
    Gebker, Rolf
    Hamada, Sandra
    Frick, Michael
    von Spiczak, Jochen
    Polacin, Malgorzata
    Enseleit, Frank
    Marx, Nikolaus
    Luscher, Thomas F.
    Ruschitzka, Frank
    Kozerke, Sebastian
    Alkadhi, Hatem
    Manka, Robert
    IMAGING, 2021, 13 (01): : 61 - 68
  • [10] Three-dimensional magnetization-prepared time-of-flight MR angiography of the carotid and vertebral arteries
    Wilman, AH
    Huston, J
    Riederer, SJ
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) : 252 - 259